DETERMINATION OF CONDITIONS FOR REDUCING ENERGY ACCUMULATION IN THE OUTPUT CIRCUITS OF POWER SOURCES OF POWERFUL GAS-DISCHARGE INSTALLATIONS

Q3 Energy
V. Martynov
{"title":"DETERMINATION OF CONDITIONS FOR REDUCING ENERGY ACCUMULATION IN THE OUTPUT CIRCUITS OF POWER SOURCES OF POWERFUL GAS-DISCHARGE INSTALLATIONS","authors":"V. Martynov","doi":"10.15407/techned2023.01.018","DOIUrl":null,"url":null,"abstract":"The energy intensity of the output circuit of a high-voltage pulse source for a gas-discharge load is determined by the totality of energies accumulated in its reactive elements in operating or transient modes. During breakdowns in the output circuit of high-voltage power supplies, the accumulated energy can be released uncontrollably and lead to ele-ment failures or technological defects. The relationship between the magnitude of the output voltage ripple, the load resistance, the parameters of the inductive-capacitive output filter, the power of the power source and the frequency of its conversion has been established. Analytical expressions are obtained that make it possible to calculate the parame-ters of the output filter of a high-voltage powerful power supply based on the allowable energy that can accumulate in the output filter while providing allowable voltage ripples at the output of the converter. It has been established that the lower the attenuation coefficient of transient processes, the more energy must be accumulated in the filter elements to ensure the required quality of the output energy. On a calculated example of a power supply with a voltage of 30 kV, a power of 450 kW, a conversion frequency of 20 kHz and output ripples of less than 1%, it is shown that for implementa-tion without oscillatory transients with significant changes in load current, the energy intensity of the output filter can exceed 1 J/kW. With an increase in the equivalent conversion frequency, this indicator can be significantly reduced. References 13, figures 4.","PeriodicalId":38557,"journal":{"name":"Technical Electrodynamics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technical Electrodynamics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15407/techned2023.01.018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Energy","Score":null,"Total":0}
引用次数: 0

Abstract

The energy intensity of the output circuit of a high-voltage pulse source for a gas-discharge load is determined by the totality of energies accumulated in its reactive elements in operating or transient modes. During breakdowns in the output circuit of high-voltage power supplies, the accumulated energy can be released uncontrollably and lead to ele-ment failures or technological defects. The relationship between the magnitude of the output voltage ripple, the load resistance, the parameters of the inductive-capacitive output filter, the power of the power source and the frequency of its conversion has been established. Analytical expressions are obtained that make it possible to calculate the parame-ters of the output filter of a high-voltage powerful power supply based on the allowable energy that can accumulate in the output filter while providing allowable voltage ripples at the output of the converter. It has been established that the lower the attenuation coefficient of transient processes, the more energy must be accumulated in the filter elements to ensure the required quality of the output energy. On a calculated example of a power supply with a voltage of 30 kV, a power of 450 kW, a conversion frequency of 20 kHz and output ripples of less than 1%, it is shown that for implementa-tion without oscillatory transients with significant changes in load current, the energy intensity of the output filter can exceed 1 J/kW. With an increase in the equivalent conversion frequency, this indicator can be significantly reduced. References 13, figures 4.
减少大功率气体放电装置电源输出电路中能量积累的条件的确定
用于气体放电负载的高压脉冲源的输出电路的能量强度由在操作模式或瞬态模式下在其电抗元件中累积的能量的总和来确定。高压电源输出电路发生故障时,积累的能量会不受控制地释放,导致设备故障或技术缺陷。建立了输出电压纹波大小、负载电阻、电感电容输出滤波器参数、电源功率及其转换频率之间的关系。获得了分析表达式,该表达式使得可以基于在转换器的输出处提供允许的电压纹波的同时可以在输出滤波器中累积的允许能量来计算高压强大电源的输出滤波器的参数。已经确定,瞬态过程的衰减系数越低,滤波器元件中必须积累越多的能量,以确保输出能量的所需质量。在电压为30kV、功率为450kW、转换频率为20kHz且输出纹波小于1%的电源的计算示例上,表明对于在没有负载电流显著变化的振荡瞬态的情况下实现,输出滤波器的能量强度可以超过1J/kW。随着等效转换频率的增加,该指标可以显著降低。参考文献13,图4。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Technical Electrodynamics
Technical Electrodynamics Energy-Energy Engineering and Power Technology
CiteScore
1.80
自引率
0.00%
发文量
72
审稿时长
4 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信