T. Taba, H. DongKhac, Q. Do, B. DaoNgoc, L. NguyễnHuy, N. NguyenViet
{"title":"Results of Bronchoscopic Lung Volume Reduction With One-way Valve in Patients With Severe Emphysema in Vietnam","authors":"T. Taba, H. DongKhac, Q. Do, B. DaoNgoc, L. NguyễnHuy, N. NguyenViet","doi":"10.14302/ISSN.2642-9241.JRD-18-1958","DOIUrl":null,"url":null,"abstract":"Methods: We performed a prospective, nonrandomized, single center longitudinal study in 30 stable COPD patients with heterogeneous severe emphysema on CT-scanner, the average age of 65.17 years old, FEV1≤35 %pred., TLC ≥ 100 %pred., RV ≥ 150 %pred. and 6MWT < 450 meters. The Zephyr one-way bronchial valves (PulmonX, Redwood City, CA, USA) with the size of 5.5 mm and 4mm were placed in lobar or segmental bronchi via flexible bronchoscopy. 28 patients were placed only one valve, 1 patient with two and 1 patient with three valves. 23 valves with the size 5.5 mm diameters and 10 valves with the size 4.0mm used. All patients received optimal medical treatment at the time of procedure and during the study period. Outcomes will be assessed at 3 months after treatment include the changes of clinic, and lung function, the occurrence of complications.","PeriodicalId":83134,"journal":{"name":"The Journal of respiratory diseases","volume":"1 1","pages":"08"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of respiratory diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14302/ISSN.2642-9241.JRD-18-1958","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Methods: We performed a prospective, nonrandomized, single center longitudinal study in 30 stable COPD patients with heterogeneous severe emphysema on CT-scanner, the average age of 65.17 years old, FEV1≤35 %pred., TLC ≥ 100 %pred., RV ≥ 150 %pred. and 6MWT < 450 meters. The Zephyr one-way bronchial valves (PulmonX, Redwood City, CA, USA) with the size of 5.5 mm and 4mm were placed in lobar or segmental bronchi via flexible bronchoscopy. 28 patients were placed only one valve, 1 patient with two and 1 patient with three valves. 23 valves with the size 5.5 mm diameters and 10 valves with the size 4.0mm used. All patients received optimal medical treatment at the time of procedure and during the study period. Outcomes will be assessed at 3 months after treatment include the changes of clinic, and lung function, the occurrence of complications.