EVALUASI KINERJA INSTALASI PENGOLAHAN AIR LIMBAH RSD MANGUSADA KABUPATEN BADUNG

Kadek Diana Harmayani
{"title":"EVALUASI KINERJA INSTALASI PENGOLAHAN AIR LIMBAH RSD MANGUSADA KABUPATEN BADUNG","authors":"Kadek Diana Harmayani","doi":"10.24843/jits.2021.v25.i01.p04","DOIUrl":null,"url":null,"abstract":"The Mangusada Regional General Hospital (RSD) as a provider of health facilities certainly produces liquid waste in every operational activity. Wastewater in the Wastewater Treatment Installation (WWTI) RSD Mangusada contains Biological Oxygen Demand (BOD5), Chemical Oxygen Demand (COD), Total Suspended Solid (TSS), ammonia, total coliform, Total Dissolved Solid (TDS), detergent, oil and fat. This study aims to evaluate the performance of the WWTI as well as to determine the content in the wastewater after being treated by the IPAL RSD Mangusada according to the reference quality standards of the Governor of Bali Regulation No.16/2016 and Regulation of the Minister of Environment and Forestry of the Republic of Indonesia Number: P.68/Menlhk/Setjen/Kum.1/8/2016. The wastewater treatment system at RSD Mangusada uses a biological system. The data used in the analysis are secondary data, namely the Bed Occupation Rate (BOR) data in June 2020, the total number of beds, the average discharge of outlets in June 2020 and parameters of the quality and quantity of wastewater in the inlet and outlet of WWTI from January 2020 to July 2020. Based on the results of testing the quality and quantity of wastewater at the WWTI of RSD Mangusada outlet, the content of waste water in the outlet of WWTI is in accordance with the regulatory standards for the reference quality standards. In addition, the effectiveness of the efficiency of the WWTI at RSD Mangusada succeeded in reducing the ammonia content of 92.35%, BOD5 64.03%, COD 63.97%, TSS 67.03%, oil and fat 64.64%, total coliform 76.84%. , and detergent at 76.25%. But the efficiency of the WWTI of RSD Mangusada was not good enough in reducing the TDS content of -3.92%. \n ","PeriodicalId":32544,"journal":{"name":"Jurnal Ilmiah Teknik Sipil","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Ilmiah Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24843/jits.2021.v25.i01.p04","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The Mangusada Regional General Hospital (RSD) as a provider of health facilities certainly produces liquid waste in every operational activity. Wastewater in the Wastewater Treatment Installation (WWTI) RSD Mangusada contains Biological Oxygen Demand (BOD5), Chemical Oxygen Demand (COD), Total Suspended Solid (TSS), ammonia, total coliform, Total Dissolved Solid (TDS), detergent, oil and fat. This study aims to evaluate the performance of the WWTI as well as to determine the content in the wastewater after being treated by the IPAL RSD Mangusada according to the reference quality standards of the Governor of Bali Regulation No.16/2016 and Regulation of the Minister of Environment and Forestry of the Republic of Indonesia Number: P.68/Menlhk/Setjen/Kum.1/8/2016. The wastewater treatment system at RSD Mangusada uses a biological system. The data used in the analysis are secondary data, namely the Bed Occupation Rate (BOR) data in June 2020, the total number of beds, the average discharge of outlets in June 2020 and parameters of the quality and quantity of wastewater in the inlet and outlet of WWTI from January 2020 to July 2020. Based on the results of testing the quality and quantity of wastewater at the WWTI of RSD Mangusada outlet, the content of waste water in the outlet of WWTI is in accordance with the regulatory standards for the reference quality standards. In addition, the effectiveness of the efficiency of the WWTI at RSD Mangusada succeeded in reducing the ammonia content of 92.35%, BOD5 64.03%, COD 63.97%, TSS 67.03%, oil and fat 64.64%, total coliform 76.84%. , and detergent at 76.25%. But the efficiency of the WWTI of RSD Mangusada was not good enough in reducing the TDS content of -3.92%.  
评估污水处理厂的性能
曼古萨达地区总医院作为保健设施的提供者,在每一项业务活动中肯定会产生液体废物。Mangusada污水处理装置(WWTI) RSD废水中含有生物需氧量(BOD5)、化学需氧量(COD)、总悬浮固体(TSS)、氨、总大肠菌群、总溶解固体(TDS)、洗涤剂、油和脂肪。本研究旨在根据第16/2016号巴厘总督条例和印度尼西亚共和国环境和林业部长条例的参考质量标准,评估污水处理系统的性能,并确定IPAL RSD Mangusada处理后的废水中的含量,编号:P.68/Menlhk/Setjen/Kum.1/8/2016。RSD Mangusada的废水处理系统使用生物系统。分析中使用的数据为二次数据,即2020年6月的床占率(BOR)数据、2020年6月的总床位数、2020年6月的出口平均排放量以及2020年1月至2020年7月的污水进出口水质和水量参数。根据RSD Mangusada出口污水处理厂污水水质和废水量的检测结果,污水处理厂出口废水含量符合参考质量标准的监管标准。此外,污水处理剂在Mangusada RSD的效率效果为氨含量降低92.35%,BOD5降低64.03%,COD降低63.97%,TSS降低67.03%,油脂降低64.64%,总大肠菌群降低76.84%。,洗涤剂为76.25%。但RSD Mangusada的WWTI效率不够好,TDS含量降低了-3.92%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
14
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书