Effect of Link Beam Length of the Eccentric Bracing System on Seismic Rehabilitation of Weak Reinforced Concrete Frames

IF 0.6 Q4 ENGINEERING, CIVIL
Touraj Niknam, H. Saberi, V. Saberi, Abbas Sadeghi, E. N. Farsangi
{"title":"Effect of Link Beam Length of the Eccentric Bracing System on Seismic Rehabilitation of Weak Reinforced Concrete Frames","authors":"Touraj Niknam, H. Saberi, V. Saberi, Abbas Sadeghi, E. N. Farsangi","doi":"10.2478/ceer-2022-0009","DOIUrl":null,"url":null,"abstract":"Abstract In this study, A reinforced concrete (RC) reference specimen with compressive strength of 250 kg/cm2 and the weak RC specimen for seismic rehabilitation with compressive strength of 150 kg/cm2 were examined in two types of structures with 6 and 12-stories. The link beam lengths of 50, 80, and 100 cm have been used in 6 and 12-stories prototypes under the effect of 7 earthquake records. The nonlinear dynamic analyses are performed. Then, The behavior of the link beam depends on its length. For short link beam lengths, shear behavior is serious, then for medium lengths, shear-flexural behavior is important, and finally, long lengths will have flexural behavior for the beam. In eccentrically braced frames, the details of the link beam and the fit of the other members must be done in such a way as to ensure its proper ductility. According to the obtained results, the performance of short link beams is much better than long link beams, and short link beams provide more energy dissipation and, at the same time, more ductility. Therefore, in the design of the link beam, mainly the shear of the link beam is considered as a ductile component. The axial force in the link beam, which is due to the application of lateral load to the structure, reduces both the bending capacity and the inelastic deformation capacity of the link beam, so it can be explained that in steel eccentric braces, the link beam is symmetrical between the two main components of the brace and it can affect the strength of the structure against lateral loads.","PeriodicalId":54121,"journal":{"name":"Civil and Environmental Engineering Reports","volume":"32 1","pages":"152 - 175"},"PeriodicalIF":0.6000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Civil and Environmental Engineering Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/ceer-2022-0009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract In this study, A reinforced concrete (RC) reference specimen with compressive strength of 250 kg/cm2 and the weak RC specimen for seismic rehabilitation with compressive strength of 150 kg/cm2 were examined in two types of structures with 6 and 12-stories. The link beam lengths of 50, 80, and 100 cm have been used in 6 and 12-stories prototypes under the effect of 7 earthquake records. The nonlinear dynamic analyses are performed. Then, The behavior of the link beam depends on its length. For short link beam lengths, shear behavior is serious, then for medium lengths, shear-flexural behavior is important, and finally, long lengths will have flexural behavior for the beam. In eccentrically braced frames, the details of the link beam and the fit of the other members must be done in such a way as to ensure its proper ductility. According to the obtained results, the performance of short link beams is much better than long link beams, and short link beams provide more energy dissipation and, at the same time, more ductility. Therefore, in the design of the link beam, mainly the shear of the link beam is considered as a ductile component. The axial force in the link beam, which is due to the application of lateral load to the structure, reduces both the bending capacity and the inelastic deformation capacity of the link beam, so it can be explained that in steel eccentric braces, the link beam is symmetrical between the two main components of the brace and it can affect the strength of the structure against lateral loads.
偏心支撑体系连接梁长度对弱钢筋混凝土框架抗震加固的影响
摘要在本研究中,在6层和12层的两种结构中,对抗压强度为250 kg/cm2的钢筋混凝土(RC)参考试件和抗压强度为150 kg/cm2的用于抗震修复的弱RC试件进行了检测。在7次地震记录的影响下,6层和12层原型中使用了50、80和100厘米的连接梁长度。进行了非线性动力学分析。然后,连接梁的行为取决于其长度。对于短连接梁长度,剪切行为是严重的,然后对于中等长度,剪切-弯曲行为是重要的,最后,长长度的梁将具有弯曲行为。在偏心支撑框架中,连接梁的细节和其他构件的配合必须确保其适当的延性。根据所获得的结果,短连接梁的性能比长连接梁好得多,并且短连接梁提供了更多的能量耗散,同时提供了更高的延性。因此,在连接梁的设计中,主要将连接梁的剪力视为延性构件。由于向结构施加横向荷载,连接梁中的轴向力降低了连接梁的弯曲能力和非弹性变形能力,因此可以解释为,在钢偏心支撑中,连接梁在支撑的两个主要部件之间是对称的,它会影响结构抵抗横向荷载的强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
14.30%
发文量
40
审稿时长
52 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信