The efficacy of augmentative anti-rotational plating plus decortication and autogenic bone grafting for aseptic nonunion after intramedullary nailing of femoral shaft fracture

Yonggang Li, Hanbing Xing, X. Qi, Mingxing Liu, Zhiyong Wang, Xiguang Sang
{"title":"The efficacy of augmentative anti-rotational plating plus decortication and autogenic bone grafting for aseptic nonunion after intramedullary nailing of femoral shaft fracture","authors":"Yonggang Li, Hanbing Xing, X. Qi, Mingxing Liu, Zhiyong Wang, Xiguang Sang","doi":"10.1097/EC9.0000000000000022","DOIUrl":null,"url":null,"abstract":"Abstract Background: Femoral interlocking intramedullary (IM) nailing fixation is an effective method for the treatment of femoral shaft fractures. Aseptic nonunion of femoral shaft fracture after IM nailing is uncommon. Currently, the treatment for aseptic femoral shaft nonunion is controversial. The aim of this study was to investigate the clinical effect of augmentative antirotational plating plus decortication and autogenic bone grafting for aseptic femoral shaft nonunion after IM nailing failure. Methods: A retrospective study was conducted on 25 cases of aseptic femoral shaft fracture nonunion treated with IM nailing from January 2015 to August 2019. All patients were treated by leaving the nail in situ, debridement of nonunion sites, decortication, autogenous iliac bone grafting, and augmentative antirotational plating fixation. The time to fracture union and complications were recorded. Results: All patients were followed up for 12–18 months. The union rate after revision surgery was 100%. The average union time was 5.5 months (range, 4-10). Subjective pain symptoms had disappeared in all patients. There were no incision infections or internal fixator fatigue fractures. Average scores of the physical function and bodily pain components of the SF-36 were 95.5 (range, 91-98) and 94.1 (range, 90-97), respectively. No other obvious complications occurred postoperatively. Conclusion: Augmentative antirotational plating plus decortication and autogenic bone grafting is an excellent choice for treating femoral shaft fracture nonunion after IM nailing; this approach has an overall high union rate and few complications.","PeriodicalId":72895,"journal":{"name":"Emergency and critical care medicine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Emergency and critical care medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/EC9.0000000000000022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background: Femoral interlocking intramedullary (IM) nailing fixation is an effective method for the treatment of femoral shaft fractures. Aseptic nonunion of femoral shaft fracture after IM nailing is uncommon. Currently, the treatment for aseptic femoral shaft nonunion is controversial. The aim of this study was to investigate the clinical effect of augmentative antirotational plating plus decortication and autogenic bone grafting for aseptic femoral shaft nonunion after IM nailing failure. Methods: A retrospective study was conducted on 25 cases of aseptic femoral shaft fracture nonunion treated with IM nailing from January 2015 to August 2019. All patients were treated by leaving the nail in situ, debridement of nonunion sites, decortication, autogenous iliac bone grafting, and augmentative antirotational plating fixation. The time to fracture union and complications were recorded. Results: All patients were followed up for 12–18 months. The union rate after revision surgery was 100%. The average union time was 5.5 months (range, 4-10). Subjective pain symptoms had disappeared in all patients. There were no incision infections or internal fixator fatigue fractures. Average scores of the physical function and bodily pain components of the SF-36 were 95.5 (range, 91-98) and 94.1 (range, 90-97), respectively. No other obvious complications occurred postoperatively. Conclusion: Augmentative antirotational plating plus decortication and autogenic bone grafting is an excellent choice for treating femoral shaft fracture nonunion after IM nailing; this approach has an overall high union rate and few complications.
增强型抗旋转钢板加自体骨移植治疗股骨干骨折髓内钉术后无菌性骨不连的疗效
摘要背景:股骨交锁髓内钉内固定是治疗股骨干骨折的有效方法。IM钉内固定后股骨干骨折无菌性骨不连不常见。目前,无菌性股骨干骨不连的治疗方法存在争议。本研究的目的是探讨增强型抗旋转钢板加去骨和自体骨移植治疗IM钉失败后无菌性股骨干骨不连的临床效果。方法:回顾性分析2015年1月至2019年8月应用IM钉治疗无菌性股骨干骨折不连25例的临床资料。所有患者均采用原位留钉、骨不连部位清创、去骨、自体髂骨移植和增强型抗旋转钢板内固定治疗。记录骨折愈合时间及并发症。结果:所有患者随访12-18年 月。翻修手术后的愈合率为100%。平均愈合时间为5.5 月(范围4-10)。所有患者的主观疼痛症状均消失。没有切口感染或内固定器疲劳性骨折。SF-36的身体功能和身体疼痛成分的平均得分分别为95.5(范围91-98)和94.1(范围90-97)。术后无其他明显并发症发生。结论:增强型抗旋转钢板加自体骨移植是治疗IM钉内固定后股骨干骨折不愈合的良好选择;这种方法总体上具有较高的愈合率和较少的并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信