M. Toossi, M. Khosroabadi, Mohammad Mehrpouyan, H. R. Moghaddam
{"title":"Assessment of Maximum Entrance Skin Dose of Patients Undergoing Cardiac Interventional Procedures and Its Correlation with Other Dosimetric Parameters","authors":"M. Toossi, M. Khosroabadi, Mohammad Mehrpouyan, H. R. Moghaddam","doi":"10.22038/IJMP.2019.33109.1403","DOIUrl":null,"url":null,"abstract":"Introduction: In recent years, the number of complex coronary angiography (CA) is increasing rapidly. These procedures have a significant contribution to medical exposure to the general population. Exposure of patients to high doses of x-rays could cause deterministic effects on the skin. Therefore, the assessment of radiation doses of patients is of great importance. This study aimed to assess maximum entrance skin dose (MESD) of patients who underwent interventional cardiology procedures. Moreover, it was attempted to determine the correlation between MESD and other relevant dosimetric parameters. Material and Methods: The MESDs of 32 patients who underwent CA procedures were measured by an array of thermoluminescence dosimeters (TLDs). In this study, a Perspex tray consisting of 5 rows and 6 columns was used to hold the TLDs. Its long axis was perpendicular to the long axis of the table, and the top edges of the tray were approximately equal to the patient’s shoulders. Results: The results revealed a linear relationship between dose area product (DAP) values and MESDs (R2=0.89; P=0.00). In addition, there was a significant association between MESD and fluoroscopy time (R2=0.89). Moreover, a weak correlation was observed between MESD and the number of frames per second (R2=0.23). Conclusion: According to the results, the recorded DAP values and fluoroscopy time can be used to estimate the MESDs of patients undergoing coronary fluoroscopy procedures.","PeriodicalId":14613,"journal":{"name":"Iranian Journal of Medical Physics","volume":"17 1","pages":"235-246"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/IJMP.2019.33109.1403","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: In recent years, the number of complex coronary angiography (CA) is increasing rapidly. These procedures have a significant contribution to medical exposure to the general population. Exposure of patients to high doses of x-rays could cause deterministic effects on the skin. Therefore, the assessment of radiation doses of patients is of great importance. This study aimed to assess maximum entrance skin dose (MESD) of patients who underwent interventional cardiology procedures. Moreover, it was attempted to determine the correlation between MESD and other relevant dosimetric parameters. Material and Methods: The MESDs of 32 patients who underwent CA procedures were measured by an array of thermoluminescence dosimeters (TLDs). In this study, a Perspex tray consisting of 5 rows and 6 columns was used to hold the TLDs. Its long axis was perpendicular to the long axis of the table, and the top edges of the tray were approximately equal to the patient’s shoulders. Results: The results revealed a linear relationship between dose area product (DAP) values and MESDs (R2=0.89; P=0.00). In addition, there was a significant association between MESD and fluoroscopy time (R2=0.89). Moreover, a weak correlation was observed between MESD and the number of frames per second (R2=0.23). Conclusion: According to the results, the recorded DAP values and fluoroscopy time can be used to estimate the MESDs of patients undergoing coronary fluoroscopy procedures.
期刊介绍:
Iranian Journal of Medical Physics (IJMP) is the official scientific bimonthly publication of the Iranian Association of Medical Physicists. IJMP is an international and multidisciplinary journal, peer review, free of charge publication and open access. This journal devoted to publish Original Papers, Review Articles, Short Communications, Technical Notes, Editorial and Letters to the Editor in the field of “Medical Physics” involving both basic and clinical research. Submissions of manuscript from all countries are welcome and will be reviewed by at least two expert reviewers.