Impact of 6MV and 10MV flattened and flattening filter free beam in whole brain radiotherapy – A treatment planning study.

Q3 Health Professions
Tamilarsu Suresh, Saminathan Madeswaran
{"title":"Impact of 6MV and 10MV flattened and flattening filter free beam in whole brain radiotherapy – A treatment planning study.","authors":"Tamilarsu Suresh, Saminathan Madeswaran","doi":"10.22038/IJMP.2020.46947.1740","DOIUrl":null,"url":null,"abstract":"Introduction: To study the impact of 6MV and 10MV flattened beam (FB) and flattening filter free beam (FFF) in whole brain radiotherapy (WBRT) by using volumetric arc therapy (VMAT).Materials and Methods: Twenty whole brain radiotherapy patients were selected randomly and the dose prescription was 30Gy, which is delivered in 10 fractions. Planning target volume (PTV) and organ at risk (OAR’S) were contoured. The four VMAT plans, like 6MV FB, 6MV FFF, 10MV FB and 10MV FFF were generated for each patient in Eclipse Treatment Planning system. PTV coverage, OAR’s doses and delivery monitoring units (MU) were noted.Results: The 6MV FB and FFF beam plan were statistically significant (p","PeriodicalId":14613,"journal":{"name":"Iranian Journal of Medical Physics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/IJMP.2020.46947.1740","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: To study the impact of 6MV and 10MV flattened beam (FB) and flattening filter free beam (FFF) in whole brain radiotherapy (WBRT) by using volumetric arc therapy (VMAT).Materials and Methods: Twenty whole brain radiotherapy patients were selected randomly and the dose prescription was 30Gy, which is delivered in 10 fractions. Planning target volume (PTV) and organ at risk (OAR’S) were contoured. The four VMAT plans, like 6MV FB, 6MV FFF, 10MV FB and 10MV FFF were generated for each patient in Eclipse Treatment Planning system. PTV coverage, OAR’s doses and delivery monitoring units (MU) were noted.Results: The 6MV FB and FFF beam plan were statistically significant (p
6MV和10MV扁平化和扁平化无滤波器光束在全脑放射治疗中的影响——一项治疗计划研究。
前言:研究6MV、10MV平坦束(FB)和平坦无滤波束(FFF)在体积弧治疗(VMAT)全脑放疗(WBRT)中的影响。材料与方法:随机选取全脑放疗患者20例,剂量处方为30Gy,分10次给药。绘制计划靶体积(PTV)和危险器官(OAR)。在Eclipse治疗计划系统中为每位患者生成6MV FB、6MV FFF、10MV FB和10MV FFF四个VMAT计划。注意到PTV的覆盖率、OAR的剂量和交付监测单位。结果:6MV FB和FFF波束计划差异有统计学意义(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Iranian Journal of Medical Physics
Iranian Journal of Medical Physics Health Professions-Radiological and Ultrasound Technology
CiteScore
1.00
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊介绍: Iranian Journal of Medical Physics (IJMP) is the official scientific bimonthly publication of the Iranian Association of Medical Physicists. IJMP is an international and multidisciplinary journal, peer review, free of charge publication and open access. This journal devoted to publish Original Papers, Review Articles, Short Communications, Technical Notes, Editorial and Letters to the Editor in the field of “Medical Physics” involving both basic and clinical research. Submissions of manuscript from all countries are welcome and will be reviewed by at least two expert reviewers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信