{"title":"Effects of pulse-like ground motions parameters on inter-story drift spectra of multi-story buildings","authors":"B. Ghanbari, A. Akhaveissy","doi":"10.1504/IJSTRUCTE.2017.081671","DOIUrl":null,"url":null,"abstract":"This article attempts to study the effect of various pulse-like ground motion parameters and local site conditions on the linear response of different multi-story buildings with special shear and flexural behaviour. The multi-story buildings are modelled using a combination of a shear and flexural beams with representative lateral stiffness ratios. A total of 61 near-fault pulse-like ground motions are selected for this study. The effects of peak ground velocity (PGV), PGV/PGA, rupture distance, Arias intensity, earthquake magnitude and local site conditions on maximum inter-story drift spectra (MIDS) and distribution of the inter-story drift ratio (IDR) along the height of the multi-story buildings are evaluated. It was observed that both the fundamental period of the structure and the lateral stiffness ratio can significantly change maximum inter-story drift demands in buildings subjected to pulse-like ground motions. The near-fault pulse-like ground motions are more dangerous for multi-story buildings with flexural behaviour than those with shear behaviour. The effects of peak ground velocity (PGV) and Arias intensity (I) on inter-story drift spectra is more obvious than others parameters.","PeriodicalId":38785,"journal":{"name":"International Journal of Structural Engineering","volume":"8 1","pages":"60"},"PeriodicalIF":0.7000,"publicationDate":"2017-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1504/IJSTRUCTE.2017.081671","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Structural Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJSTRUCTE.2017.081671","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 2
Abstract
This article attempts to study the effect of various pulse-like ground motion parameters and local site conditions on the linear response of different multi-story buildings with special shear and flexural behaviour. The multi-story buildings are modelled using a combination of a shear and flexural beams with representative lateral stiffness ratios. A total of 61 near-fault pulse-like ground motions are selected for this study. The effects of peak ground velocity (PGV), PGV/PGA, rupture distance, Arias intensity, earthquake magnitude and local site conditions on maximum inter-story drift spectra (MIDS) and distribution of the inter-story drift ratio (IDR) along the height of the multi-story buildings are evaluated. It was observed that both the fundamental period of the structure and the lateral stiffness ratio can significantly change maximum inter-story drift demands in buildings subjected to pulse-like ground motions. The near-fault pulse-like ground motions are more dangerous for multi-story buildings with flexural behaviour than those with shear behaviour. The effects of peak ground velocity (PGV) and Arias intensity (I) on inter-story drift spectra is more obvious than others parameters.