REPRODUCIBILITY OF MEASUREMENTS OF PRE-CONTACT LENS TEAR FILM KINETICS UNDER NORMAL AND ADVERSE ENVIRONMENTAL CONDITIONS

M. Guillon, Kishan Patel, Ruchi Gupta, Trisha Patel, C. Maissa
{"title":"REPRODUCIBILITY OF MEASUREMENTS OF PRE-CONTACT LENS TEAR FILM KINETICS UNDER NORMAL AND ADVERSE ENVIRONMENTAL CONDITIONS","authors":"M. Guillon, Kishan Patel, Ruchi Gupta, Trisha Patel, C. Maissa","doi":"10.22374/jclrs.v5i1.41","DOIUrl":null,"url":null,"abstract":"Objectives: To evaluate the reproducibility of tear film kinetics (TFK) measurements during the full interblink period in habitual wearers of delefilcon A daily disposable contact lenses under different environmentalconditions.Methods: Two independent studies were performed, one involving 90 eyes measurements in 49 subjects and the second involving 58 eyes measurements in 32 subjects, after 3 hours of conventional wear in normal environmental conditions (NEC) and an additional 3 hours of computer use under adverse environmental conditions (AEC), defined as 20% relative humidity (RH). Digital videos were obtained by non-invasive Tearscope illumination, followed by a parallel-group post-hoc comparative analysis by masked investigators of the videos obtained during the two studies. Parameters analyzed included non-invasive break-up time (NIBUT); dehydration speed (DS) between the initial break and the spontaneous blink, and minimum protected area (MPA) of the lens surface by the tear film.Results: After 3 hours of wear in normal environmental conditions, the overall population (n=148) had a mean NIBUT of 7.1 ± 7.0 sec, a mean DS of 0.28 ± 0.66 mm2/sec, and a mean MPA of 93.4 ± 16.6%. After an additional 3 hours in AEC, mean NIBUT was 8.4 ± 9.8 mm2/sec, mean DS was 0.26 ± 0.75 mm2/sec, and MPA was 95.2 ± 14.0%. The TFK characteristics in the two studies were similar for each environmental condition: after 3 hours of conventional wear, the mean [95% CI] differences between the two studies were −0.9 [−3.2, +1.4] sec for NIBUT, 0.00 [−0.22, +0.22] mm2/s for DS, and 2.0 [−3.5, +7.4] % for MPA; after an additional 3 hours of wear in 20% RH, the mean [95% CI] differences between the two studies were −1.3 [−4.5, +1.9] sec for NIBUT, −0.03 [−0.28, +0.22] mm2/s for DS and −0.3 [−4.9, +4.3] % for MPA. Conclusions: This analysis showed that the measurement of pre-contact lens TFK carried out in two differ-ent studies involving habitual wearers of delefilcon A having worn their contact lenses for an initial 3 hours under NEC and a further 3 hours under low (20%) hygrometry (AEC) produced similar on-eye wettability, including a long NIBUT, slow DS following the initial break, and wide MPA at the next blink. The results establish the reproducibility of the measurement of pre-contact lens TFK using the Tearscope; by quantifying the measurement variability, the data makes it possible to carry out precise sample size calculations in future studies involving pre-contact lens TFK measurements to quantify on-eye wettability under both normal and adverse environmental low (20% RH) hygrometric conditions.","PeriodicalId":73690,"journal":{"name":"Journal of contact lens research & science","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of contact lens research & science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22374/jclrs.v5i1.41","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate the reproducibility of tear film kinetics (TFK) measurements during the full interblink period in habitual wearers of delefilcon A daily disposable contact lenses under different environmentalconditions.Methods: Two independent studies were performed, one involving 90 eyes measurements in 49 subjects and the second involving 58 eyes measurements in 32 subjects, after 3 hours of conventional wear in normal environmental conditions (NEC) and an additional 3 hours of computer use under adverse environmental conditions (AEC), defined as 20% relative humidity (RH). Digital videos were obtained by non-invasive Tearscope illumination, followed by a parallel-group post-hoc comparative analysis by masked investigators of the videos obtained during the two studies. Parameters analyzed included non-invasive break-up time (NIBUT); dehydration speed (DS) between the initial break and the spontaneous blink, and minimum protected area (MPA) of the lens surface by the tear film.Results: After 3 hours of wear in normal environmental conditions, the overall population (n=148) had a mean NIBUT of 7.1 ± 7.0 sec, a mean DS of 0.28 ± 0.66 mm2/sec, and a mean MPA of 93.4 ± 16.6%. After an additional 3 hours in AEC, mean NIBUT was 8.4 ± 9.8 mm2/sec, mean DS was 0.26 ± 0.75 mm2/sec, and MPA was 95.2 ± 14.0%. The TFK characteristics in the two studies were similar for each environmental condition: after 3 hours of conventional wear, the mean [95% CI] differences between the two studies were −0.9 [−3.2, +1.4] sec for NIBUT, 0.00 [−0.22, +0.22] mm2/s for DS, and 2.0 [−3.5, +7.4] % for MPA; after an additional 3 hours of wear in 20% RH, the mean [95% CI] differences between the two studies were −1.3 [−4.5, +1.9] sec for NIBUT, −0.03 [−0.28, +0.22] mm2/s for DS and −0.3 [−4.9, +4.3] % for MPA. Conclusions: This analysis showed that the measurement of pre-contact lens TFK carried out in two differ-ent studies involving habitual wearers of delefilcon A having worn their contact lenses for an initial 3 hours under NEC and a further 3 hours under low (20%) hygrometry (AEC) produced similar on-eye wettability, including a long NIBUT, slow DS following the initial break, and wide MPA at the next blink. The results establish the reproducibility of the measurement of pre-contact lens TFK using the Tearscope; by quantifying the measurement variability, the data makes it possible to carry out precise sample size calculations in future studies involving pre-contact lens TFK measurements to quantify on-eye wettability under both normal and adverse environmental low (20% RH) hygrometric conditions.
正常和不良环境条件下隐形眼镜前泪膜动力学测量的再现性
目的:评估不同环境条件下戴delefilcon A日常一次性隐形眼镜的习惯性佩戴者在整个连接期间泪膜动力学(TFK)测量的可重复性。方法:进行了两项独立研究,一项涉及49名受试者的90只眼睛测量,另一项涉及32名受试人的58只眼睛测量。在正常环境条件下(NEC)常规佩戴3小时后,以及在不利环境条件(AEC)下(定义为20%相对湿度(RH))额外使用计算机3小时后。数字视频是通过非侵入性Tearscope照明获得的,然后由蒙面调查人员对两项研究期间获得的视频进行平行组事后比较分析。分析的参数包括无创破裂时间(NIBUT);初始破裂和自发眨眼之间的脱水速度(DS)以及泪膜对晶状体表面的最小保护面积(MPA)。结果:在正常环境条件下磨损3小时后,总体(n=148)的平均NIBUT为7.1±7.0秒,平均DS为0.28±0.66 mm2/sec,平均MPA为93.4±16.6%,MPA为95.2±14.0%。两项研究中的TFK特性在每种环境条件下都是相似的:常规磨损3小时后,两项研究之间的平均[95%CI]差异为:NIBUT为-0.9[−3.2,+1.4]秒,DS为0.00[−0.22,+0.22]mm2/s,MPA为2.0[−3.5,+7.4]%;在20%相对湿度下再磨损3小时后,两项研究之间的平均[95%CI]差异为:NIBUT为−1.3[−4.5,+1.9]秒,DS为−0.03[−0.28,+0.22]mm2/s,MPA为−0.3[−4.9,+4.3]%。结论:该分析表明,在两项不同的研究中进行的隐形眼镜前TFK的测量,涉及delefilcon A的习惯性佩戴者,他们在NEC下佩戴隐形眼镜最初3小时,在低(20%)湿度(AEC)下再佩戴3小时,产生了类似的眼睛润湿性,包括长NIBUT、,并且在下一眨眼时出现宽MPA。该结果建立了使用Tearscope测量前隐形眼镜TFK的再现性;通过量化测量可变性,该数据使得在未来的研究中进行精确的样本量计算成为可能,这些研究涉及隐形眼镜前TFK测量,以量化正常和不利环境低(20%RH)湿度条件下的眼睛润湿性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信