Ultra performance liquid chromatographic method for simultaneous quantification of plerixafor and related substances in an injection formulation

G. Venkata Narasimha Rao, B. Ravi, M. Sunil Kumar, P. Manoj, R. Venkata Nadh
{"title":"Ultra performance liquid chromatographic method for simultaneous quantification of plerixafor and related substances in an injection formulation","authors":"G. Venkata Narasimha Rao, B. Ravi, M. Sunil Kumar, P. Manoj, R. Venkata Nadh","doi":"10.1080/23312009.2016.1275955","DOIUrl":null,"url":null,"abstract":"Abstract Plerixafor (PLX) injections are administered to patients with cancers of lymphocytes (non-Hodgkin’s lymphoma) and plasma cells (multiple myeloma). The main objective of the current study was to develop a short reverse phase chromatographic method for the simultaneous quantification of PLX and its impurities, in an injection formulation, to reduce the time required for these quality tests. Furthermore, the present work describes the role of nonalkyl branched nonquaternary ion pair reagent in improving the peak shape and reducing column equilibration time. The separation of PLX and its related substances is pH dependent (optimum pH = 2.50) and was achieved on an octadecylsilyl (C18) column. The method was validated for its intended purpose in accordance with the current regulatory guidelines for validation. The proposed method can be applied for quality control, release, and stability analyses of active pharmaceutical ingredient, PLX, as well as finished products, PLX injections.","PeriodicalId":10640,"journal":{"name":"Cogent Chemistry","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/23312009.2016.1275955","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cogent Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/23312009.2016.1275955","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Abstract Plerixafor (PLX) injections are administered to patients with cancers of lymphocytes (non-Hodgkin’s lymphoma) and plasma cells (multiple myeloma). The main objective of the current study was to develop a short reverse phase chromatographic method for the simultaneous quantification of PLX and its impurities, in an injection formulation, to reduce the time required for these quality tests. Furthermore, the present work describes the role of nonalkyl branched nonquaternary ion pair reagent in improving the peak shape and reducing column equilibration time. The separation of PLX and its related substances is pH dependent (optimum pH = 2.50) and was achieved on an octadecylsilyl (C18) column. The method was validated for its intended purpose in accordance with the current regulatory guidelines for validation. The proposed method can be applied for quality control, release, and stability analyses of active pharmaceutical ingredient, PLX, as well as finished products, PLX injections.
超高效液相色谱法同时定量注射制剂中多立沙及相关物质
摘要Plerixafor(PLX)注射液用于淋巴细胞癌(非霍奇金淋巴瘤)和浆细胞癌(多发性骨髓瘤)患者。本研究的主要目的是开发一种短的反相色谱法,用于同时定量注射制剂中的PLX及其杂质,以减少这些质量测试所需的时间。此外,本工作描述了非烷基支链非季离子对试剂在改善峰形状和缩短柱平衡时间方面的作用。PLX及其相关物质的分离依赖于pH(最适pH=2.50),并在十八烷基甲硅烷基(C18)柱上实现。根据现行的验证监管指南,对该方法进行了预期用途的验证。所提出的方法可用于活性药物成分PLX以及成品PLX注射液的质量控制、释放和稳定性分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Cogent Chemistry
Cogent Chemistry CHEMISTRY, MULTIDISCIPLINARY-
自引率
0.00%
发文量
0
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信