Visual Performance of a Polynomial Extended Depth of Focus Intraocular Lens

P. Stodulka, M. Slovák
{"title":"Visual Performance of a Polynomial Extended Depth of Focus Intraocular Lens","authors":"P. Stodulka, M. Slovák","doi":"10.4236/ojoph.2021.113017","DOIUrl":null,"url":null,"abstract":"Purpose: To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediate vision while keeping the quality of distance vision equal to a monofocal lens. Methods: 18 patients (11 female, 7 male, mean age of 69.4 years) with bilateral cataract and regular corneal astigmatism ≤ 1.0 D underwent bilateral cataract surgery with ISOPURE implantation. Patients were followed for up to 6 months. Measured parameters were uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity at 80 cm and 66 cm (DCI80VA, DCI66VA) subjective refraction, defocus curve, tolerance of cylinder induction, and contrast sensitivity. The data from all implanted eyes (all-eyes) and a subset only including the first eye implanted for each patient were analysed. Results: The mean manifest refraction spherical equivalent (MRSE) decreased from 1.05 D pre-operatively to ?0.15 D at the 4 - 6 month assessment, with 80.6% of eyes within ±0.50 D of emmetropia. At the final follow-up, mean (SD) monocular CDVA was ?0.06 (0.04) logMAR, DCI80VA was 0.18 (0.08) logMAR and DCI66VA was 0.27 (0.13) logMAR. Despite a cylinder induction of ?0.50 D, uncorrected distance visual acuity of 0.02 logMAR was still achieved. Conclusion: The ISOPURE intraocular lens provides excellent distance corrected visual acuity for far and intermediate distances along with high contrast sensitivity and good tolerance of residual refractive cylinder.","PeriodicalId":60672,"journal":{"name":"眼科学期刊(英文)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"眼科学期刊(英文)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4236/ojoph.2021.113017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Purpose: To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediate vision while keeping the quality of distance vision equal to a monofocal lens. Methods: 18 patients (11 female, 7 male, mean age of 69.4 years) with bilateral cataract and regular corneal astigmatism ≤ 1.0 D underwent bilateral cataract surgery with ISOPURE implantation. Patients were followed for up to 6 months. Measured parameters were uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity at 80 cm and 66 cm (DCI80VA, DCI66VA) subjective refraction, defocus curve, tolerance of cylinder induction, and contrast sensitivity. The data from all implanted eyes (all-eyes) and a subset only including the first eye implanted for each patient were analysed. Results: The mean manifest refraction spherical equivalent (MRSE) decreased from 1.05 D pre-operatively to ?0.15 D at the 4 - 6 month assessment, with 80.6% of eyes within ±0.50 D of emmetropia. At the final follow-up, mean (SD) monocular CDVA was ?0.06 (0.04) logMAR, DCI80VA was 0.18 (0.08) logMAR and DCI66VA was 0.27 (0.13) logMAR. Despite a cylinder induction of ?0.50 D, uncorrected distance visual acuity of 0.02 logMAR was still achieved. Conclusion: The ISOPURE intraocular lens provides excellent distance corrected visual acuity for far and intermediate distances along with high contrast sensitivity and good tolerance of residual refractive cylinder.
多项式扩展聚焦深度人工晶状体的视觉性能
目的:临床评估一种新的扩展焦深人工晶状体(ISOPURE,PhysIOL),该晶状体基于独特的多项式概念进行光学设计修改,以提高中间视力,同时保持与单焦点晶状体相同的远视质量。方法:对18例(女11例,男7例,平均年龄69.4岁)双侧白内障、规则性角膜散光≤1.0D的患者行ISOPURE植入术。对患者进行了长达6个月的随访。测量的参数为未矫正(UDVA)和矫正远距视力(CDVA)、未矫正(UIVA)和80厘米和66厘米远距矫正中等视力(DCI80VA,DCI66VA)的主观屈光度、散焦曲线、圆柱体诱导耐受性和对比敏感度。分析了每个患者的所有植入眼睛(所有眼睛)和仅包括第一只植入眼睛的子集的数据。结果:平均显着折射球当量(MRSE)从术前的1.05D降至?在4-6个月的评估中为0.15 D,其中80.6%的眼睛在正视眼±0.50 D范围内。在最后的随访中,单眼CDVA的平均值(SD)为?0.06(0.04)logMAR,DCI80VA为0.18(0.08)logMAR,DCI66VA为0.27(0.13)logMAR。尽管气缸感应?0.50 D,裸眼远视力仍达到0.02 logMAR。结论:ISOPURE人工晶状体具有良好的远距和中距矫正视力,同时具有较高的对比敏感度和对残余屈光不正的良好耐受性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
232
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书