Persistent Intraocular Pressure Elevation after Silicon Oil Removal in Patients with Post-Pars Plana Vitrectomy

Muhannad Ghazi AnNasseh, S. Rattan, Didar Sddeq Anwar
{"title":"Persistent Intraocular Pressure Elevation after Silicon Oil Removal in Patients with Post-Pars Plana Vitrectomy","authors":"Muhannad Ghazi AnNasseh, S. Rattan, Didar Sddeq Anwar","doi":"10.47723/kcmj.v19i1.898","DOIUrl":null,"url":null,"abstract":"Background: It is well-known that silicon oil (SO) injection into the vitreous cavity after pars plana vitrectomy is usually associated with high intraocular pressure.\nObjectives: To determine the influence of silicon oil (SO) removal on IOP level after pars plana vitrectomy for spontaneous rhegmatogenous retinal detachment (RRD)\nSubjects and Methods: A prospective study was conducted at Ibn Al-Haitham eye teaching hospital, Baghdad- Iraq. Intraocular pressure (IOP) was measured pre and post SO removal in patients who have underwent retinal detachment surgery with SO injection of 1000 centistokes (cSt) viscosity. Baseline IOP was measured for all the patient before the SO removal. Follow-up was performed at 1, 4, and 8 weeks after SO removal. IOP was measured by Goldman applanation tonometer. Patients with IOP > 21 mm Hg at 8 weeks post-operatively with or without anti-glaucoma mediations were considered as persistent IOP elevation after SO removal.\nResult: Sixty eyes of 60 patients were included. Twenty eyes had persistent IOP elevation after SO removal on first week postoperative. It decreased to 14 eyes on 4th week after SO removal and further decreased to 12 eyes on 8th week af-ter SO removal. The percentage of persistent IOP elevation following SO remov-al was about 20%  on 8th week of SO removal. \nConclusion: Persistent IOP elevation sometimes happens after SO removal. Therefore, removing SO does not simply treat the elevated IOP happened during SO injection. Patients after SO removal should be followed up for IOP for several weeks and should be treated medically or surgically as required.","PeriodicalId":34748,"journal":{"name":"mjlh klyh Tb lkndy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"mjlh klyh Tb lkndy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47723/kcmj.v19i1.898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: It is well-known that silicon oil (SO) injection into the vitreous cavity after pars plana vitrectomy is usually associated with high intraocular pressure. Objectives: To determine the influence of silicon oil (SO) removal on IOP level after pars plana vitrectomy for spontaneous rhegmatogenous retinal detachment (RRD) Subjects and Methods: A prospective study was conducted at Ibn Al-Haitham eye teaching hospital, Baghdad- Iraq. Intraocular pressure (IOP) was measured pre and post SO removal in patients who have underwent retinal detachment surgery with SO injection of 1000 centistokes (cSt) viscosity. Baseline IOP was measured for all the patient before the SO removal. Follow-up was performed at 1, 4, and 8 weeks after SO removal. IOP was measured by Goldman applanation tonometer. Patients with IOP > 21 mm Hg at 8 weeks post-operatively with or without anti-glaucoma mediations were considered as persistent IOP elevation after SO removal. Result: Sixty eyes of 60 patients were included. Twenty eyes had persistent IOP elevation after SO removal on first week postoperative. It decreased to 14 eyes on 4th week after SO removal and further decreased to 12 eyes on 8th week af-ter SO removal. The percentage of persistent IOP elevation following SO remov-al was about 20%  on 8th week of SO removal.  Conclusion: Persistent IOP elevation sometimes happens after SO removal. Therefore, removing SO does not simply treat the elevated IOP happened during SO injection. Patients after SO removal should be followed up for IOP for several weeks and should be treated medically or surgically as required.
玻璃体切割术后硅油去除术后持续眼压升高
背景:玻璃体切割术后玻璃体腔内注射硅油通常伴有高眼压。目的:探讨硅油(SO)去除对自发性孔源性视网膜脱离(RRD)玻璃体切割术后IOP水平的影响。研究对象和方法:在伊拉克巴格达Ibn Al-Haitham眼科教学医院进行前瞻性研究。在接受视网膜脱离手术的患者中,用1000厘斯托克(cSt)粘度的SO注射,测量去除SO前后的眼压(IOP)。在取下SO之前测量所有患者的基线IOP。随访时间分别为1周、4周和8周。眼压用Goldman眼压计测量。术后8周,有或没有使用抗青光眼药物的患者IOP值为21 mm Hg,被认为是SO去除后的持续性IOP升高。结果:纳入60例患者60只眼。术后第1周摘除SO后,20只眼的IOP持续升高。术后第4周降至14眼,第8周降至12眼。SO去除后第8周持续IOP升高的百分比约为20%。结论:在SO移除后,有时会出现持续的IOP升高。因此,去除SO并不能简单地治疗注射SO时发生的IOP升高。摘除SO后的患者应随访数周,并根据需要进行药物或手术治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
34
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信