Drug-coated balloons are not inferior to drug-coated stents in the treatment of acute myocardial infarction and shorten the duration of dual antiplatelet treatment

Jing Yang, Shuting Chang, Jing Liu, Guanzhao Zhang, Yue Wang, Baixue Zhang, Zifan Nie, Yuan Dong, Bo Li
{"title":"Drug-coated balloons are not inferior to drug-coated stents in the treatment of acute myocardial infarction and shorten the duration of dual antiplatelet treatment","authors":"Jing Yang, Shuting Chang, Jing Liu, Guanzhao Zhang, Yue Wang, Baixue Zhang, Zifan Nie, Yuan Dong, Bo Li","doi":"10.1097/EC9.0000000000000050","DOIUrl":null,"url":null,"abstract":"Abstract Background Drug-coated balloons (DCBs) are an up-and-coming tactic in treating in-stent restenosis and coronary artery small vessel disease, but their efficacy in treating acute myocardial infarction needs to be further explored. Methods A meta-analysis of 7 studies was conducted to make a comparison with the results of DCB and drug-eluting stent implantation after a median follow-up of 15 months. Results A total of 922 patients were included in this analysis in total, including 375 patients in the DCB group and 547 patients in the stent group. A total of 962 vascular diseases were manifested in the 2 groups. After 6 to 24 months of follow-up, there was no statistically significant difference with respect to major adverse cardiovascular events (odds ratio [OR]: 0.82; 95% confidence interval [CI]: 0.52–1.29; Z = 0.85; P = 0.39), cardiac death (OR: 0.92; 95% CI: 0.39–2.12; Z = 0.21; P = 0.84), target lesion revascularization (OR: 1.09; 95% CI: 0.53–2.25; Z = 0.24; P = 0.81), late lumen loss (MD: −0.05; 95% CI: −0.15 to 0.06; Z = 0.85; P = 0.40), or dual antiplatelet therapy (DAPT) (OR: 1.04; 95% CI: 0.53–2.05; Z = 0.11; P = 0.91) between the 2 groups. In the DCB group, persistent residual stenosis or C-F dissection occurrence necessitated that a total of 30 patients receive extra bailout implantations. The rate of bailout stenting was 11.8% (95% CI: 7.1–16). Moreover, the DCB group had a shorter DAPT duration compared with the stent group. Conclusion Drug-coated balloons with shorter DAPT durations may be as effective and safe as stent therapy in treating acute myocardial infarction.","PeriodicalId":72895,"journal":{"name":"Emergency and critical care medicine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Emergency and critical care medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/EC9.0000000000000050","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background Drug-coated balloons (DCBs) are an up-and-coming tactic in treating in-stent restenosis and coronary artery small vessel disease, but their efficacy in treating acute myocardial infarction needs to be further explored. Methods A meta-analysis of 7 studies was conducted to make a comparison with the results of DCB and drug-eluting stent implantation after a median follow-up of 15 months. Results A total of 922 patients were included in this analysis in total, including 375 patients in the DCB group and 547 patients in the stent group. A total of 962 vascular diseases were manifested in the 2 groups. After 6 to 24 months of follow-up, there was no statistically significant difference with respect to major adverse cardiovascular events (odds ratio [OR]: 0.82; 95% confidence interval [CI]: 0.52–1.29; Z = 0.85; P = 0.39), cardiac death (OR: 0.92; 95% CI: 0.39–2.12; Z = 0.21; P = 0.84), target lesion revascularization (OR: 1.09; 95% CI: 0.53–2.25; Z = 0.24; P = 0.81), late lumen loss (MD: −0.05; 95% CI: −0.15 to 0.06; Z = 0.85; P = 0.40), or dual antiplatelet therapy (DAPT) (OR: 1.04; 95% CI: 0.53–2.05; Z = 0.11; P = 0.91) between the 2 groups. In the DCB group, persistent residual stenosis or C-F dissection occurrence necessitated that a total of 30 patients receive extra bailout implantations. The rate of bailout stenting was 11.8% (95% CI: 7.1–16). Moreover, the DCB group had a shorter DAPT duration compared with the stent group. Conclusion Drug-coated balloons with shorter DAPT durations may be as effective and safe as stent therapy in treating acute myocardial infarction.
药物包被球囊治疗急性心肌梗死不逊于药物包被支架,缩短了双重抗血小板治疗的持续时间
背景药物包被球囊(Drug-coated balloons, DCBs)是治疗支架内再狭窄和冠状动脉小血管疾病的一种很有前途的策略,但其治疗急性心肌梗死的疗效有待进一步探讨。方法对7项研究进行meta分析,比较中位随访15个月后DCB与药物洗脱支架植入术的结果。结果共纳入922例患者,其中DCB组375例,支架组547例。两组共发生血管疾病962例。随访6 ~ 24个月后,两组主要心血管不良事件发生率无统计学差异(优势比[OR]: 0.82;95%置信区间[CI]: 0.52-1.29;Z = 0.85;P = 0.39),心源性死亡(OR: 0.92;95% ci: 0.39-2.12;Z = 0.21;P = 0.84),靶病变血运重建术(OR: 1.09;95% ci: 0.53-2.25;Z = 0.24;P = 0.81),晚期管腔损失(MD:−0.05;95% CI:−0.15 ~ 0.06;Z = 0.85;P = 0.40),或双重抗血小板治疗(DAPT) (or: 1.04;95% ci: 0.53-2.05;Z = 0.11;P = 0.91)。在DCB组中,由于持续残余狭窄或C-F夹层的发生,总共有30例患者需要接受额外的救助植入。救助支架置入率为11.8% (95% CI: 7.1-16)。DCB组DAPT持续时间较支架组短。结论DAPT持续时间较短的药物包被球囊治疗急性心肌梗死与支架治疗一样安全有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信