Normalisation values for the resonant frequency of the middle ear in rats

IF 0.2 Q4 OTORHINOLARYNGOLOGY
Şule Mıdık, B. Culhaoğlu, S. Erbek, Seyra Erbek
{"title":"Normalisation values for the resonant frequency of the middle ear in rats","authors":"Şule Mıdık, B. Culhaoğlu, S. Erbek, Seyra Erbek","doi":"10.32448/ENTUPDATES.508087","DOIUrl":null,"url":null,"abstract":"p { margin-bottom: 0.08in; direction: ltr; color: rgb(0, 0, 0); }p.western { font-family: \"Cambria\", serif; font-size: 12pt; }p.cjk { font-family: \"MS Mincho\", \"MS 明朝\", monospace; font-size: 12pt; }p.ctl { font-family: \"Cambria\", serif; font-size: 12pt; } Objective : In earlier studies, the resonant frequency (RF) of the middle ear has been investigated in a number of different animals. However, no study has so far specifically addressed the measurement of RF in rats. With this in mind, in our study, multifrequency tympanometry (MFT) was performed on rats and RF value measurements were taken. The aim was to ascertain the normal values for rats used in our university experiments and to provide guidance for further research to be undertaken in this area. Materials and Methods: For the study, 16 male and 16 female adult Sprague Downey rats (32 animals, 64 ears) aged 10 months old and in healthy condition were used. MFT at 226Hz frequency and above was performed on all the rats after they had been anaesthetised. In the first instance tympanograms were recorded using the 226Hz probe tone, following which MFT measurements were performed. RF values for the middle ear were determined in the range 200-2000Hz. Results: For male rats, the mean RF value was 426.56 (± 193.01 Hz), whilst for female rats the mean was 496.88 (± 132.55) Hz. When the values obtained for the male and female rats were compared, no statistically significant difference was observed between the two groups (p=0.061). Accordingly, the mean RF value for the rats as a whole (obtained for 64 ears) was calculated to be 461.7 (± 168.02) Hz. Conclusion: In this research, RF values for the middle ear of rats has been demonstrated to be measurable. However, further research is needed into the relationship between RF and the characteristics of the middle ear in rats.","PeriodicalId":41744,"journal":{"name":"ENT Updates","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2018-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ENT Updates","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32448/ENTUPDATES.508087","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

p { margin-bottom: 0.08in; direction: ltr; color: rgb(0, 0, 0); }p.western { font-family: "Cambria", serif; font-size: 12pt; }p.cjk { font-family: "MS Mincho", "MS 明朝", monospace; font-size: 12pt; }p.ctl { font-family: "Cambria", serif; font-size: 12pt; } Objective : In earlier studies, the resonant frequency (RF) of the middle ear has been investigated in a number of different animals. However, no study has so far specifically addressed the measurement of RF in rats. With this in mind, in our study, multifrequency tympanometry (MFT) was performed on rats and RF value measurements were taken. The aim was to ascertain the normal values for rats used in our university experiments and to provide guidance for further research to be undertaken in this area. Materials and Methods: For the study, 16 male and 16 female adult Sprague Downey rats (32 animals, 64 ears) aged 10 months old and in healthy condition were used. MFT at 226Hz frequency and above was performed on all the rats after they had been anaesthetised. In the first instance tympanograms were recorded using the 226Hz probe tone, following which MFT measurements were performed. RF values for the middle ear were determined in the range 200-2000Hz. Results: For male rats, the mean RF value was 426.56 (± 193.01 Hz), whilst for female rats the mean was 496.88 (± 132.55) Hz. When the values obtained for the male and female rats were compared, no statistically significant difference was observed between the two groups (p=0.061). Accordingly, the mean RF value for the rats as a whole (obtained for 64 ears) was calculated to be 461.7 (± 168.02) Hz. Conclusion: In this research, RF values for the middle ear of rats has been demonstrated to be measurable. However, further research is needed into the relationship between RF and the characteristics of the middle ear in rats.
大鼠中耳共振频率的归一化值
P {margin-bottom: 0.08in;方向:ltr;颜色:rgb(0,0,0);} p。西部{font-family: "Cambria", serif;字体大小:12 pt;} p。cjk {font-family: "MS Mincho", "MS ming ", font-family:宋体;字体大小:12 pt;} p。ctl {font-family: "Cambria", serif;字体大小:12 pt;目的:在早期的研究中,已经对许多不同动物的中耳共振频率(RF)进行了研究。然而,到目前为止,还没有研究专门针对大鼠射频的测量。考虑到这一点,在我们的研究中,对大鼠进行了多频鼓室测量(MFT)并测量了射频值。目的是确定我们大学实验中使用的大鼠的正常值,并为在该领域进行的进一步研究提供指导。材料与方法:选用健康的10月龄成年大鼠,雄性16只,雌性16只,32只,64耳。所有大鼠麻醉后均在226Hz及以上频率下进行MFT。在第一个实例中,使用226Hz探头音记录鼓室图,随后进行MFT测量。中耳的射频值在200-2000Hz范围内确定。结果:雄性大鼠平均射频值为426.56(±193.01 Hz),雌性大鼠平均射频值为496.88(±132.55)Hz。对比雌雄大鼠所得值,两组间差异无统计学意义(p=0.061)。据此,计算出整个大鼠(64耳)的平均射频值为461.7(±168.02)Hz。结论:在本研究中,大鼠中耳的射频值被证明是可测量的。然而,射频与大鼠中耳特征之间的关系有待进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ENT Updates
ENT Updates OTORHINOLARYNGOLOGY-
自引率
0.00%
发文量
0
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信