Daniela Naranjo López, María Alejandra González Jiménez, Sebastián Buitrago Toro, Jonathan Gallego Londoño
{"title":"Inclination measurement device for hospital beds’ in ICU","authors":"Daniela Naranjo López, María Alejandra González Jiménez, Sebastián Buitrago Toro, Jonathan Gallego Londoño","doi":"10.14483/22484728.14408","DOIUrl":null,"url":null,"abstract":"Ventilator-associated pneumonia is acquired by many patients connected to an artificial airway, causing their death of a great percentage to those who are affected. A close relationship has been found between ventilator-associated pneumonia and hospital beds tilting angle which the patients rest on. The correct position has been established between 30° and 45° to reduce the likelihood of ventilator-associated pneumonia; so a tilt sensor linked to the hospital beds is a good method for measuring. The present article describes an electronic device which was developed able to create a link between an IMU sensor connected to a microcontroller and a Wi-Fi module that allows to display, in a real time graphical interface, located in the control center, the current position of hospital’s beds for being monitored by the nursing staff providing a record of the patients’ status in intensive care and emergency units. Device’s performance was checked by hysteresis and fixed position test along a previously defined time where errors in measurement of inclination remain within a suitable range.","PeriodicalId":34191,"journal":{"name":"Vision Electronica","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vision Electronica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14483/22484728.14408","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Ventilator-associated pneumonia is acquired by many patients connected to an artificial airway, causing their death of a great percentage to those who are affected. A close relationship has been found between ventilator-associated pneumonia and hospital beds tilting angle which the patients rest on. The correct position has been established between 30° and 45° to reduce the likelihood of ventilator-associated pneumonia; so a tilt sensor linked to the hospital beds is a good method for measuring. The present article describes an electronic device which was developed able to create a link between an IMU sensor connected to a microcontroller and a Wi-Fi module that allows to display, in a real time graphical interface, located in the control center, the current position of hospital’s beds for being monitored by the nursing staff providing a record of the patients’ status in intensive care and emergency units. Device’s performance was checked by hysteresis and fixed position test along a previously defined time where errors in measurement of inclination remain within a suitable range.