Comparative analysis of risks which are accompanied by the use of typical and boundary gases concentrations for the diagnostics of high voltage transformers
{"title":"Comparative analysis of risks which are accompanied by the use of typical and boundary gases concentrations for the diagnostics of high voltage transformers","authors":"O. Shutenko, O. Proskurnia, V. Abramov","doi":"10.6001/ENERGETIKA.V64I3.3806","DOIUrl":null,"url":null,"abstract":"The aim of the scientific research provided in the article is to increase the operational reliability of high-voltage power transformers by reducing the possible risks when diagnosing high-voltage equipment based on the analysis of gases dissolved in oil. We described the method for determining the boundary (typical) gas concentrations by the integral function method, which is recommended by some existing standards, and the author’s method for determining the boundary concentrations of gases ensuring a minimum of possible economic damage in case of taking erroneous decisions. The analysis of boundary concentrations of gases obtained by the method of integral functions and the method of minimum risk showed that boundary values differ significantly for the same data, depending on the method of determination. To determine the reliability of decision-making we used a comparative analysis of risk values that may arise while making a diagnosis of high-voltage transformers based on the analysis of gases dissolved in oil, the boundary values of gas concentrations obtained by the integral function method and the minimum risk method, as well as the boundary values of gas concentrations regulated by known international and national standards were used. The study has revealed that the use of typical values of gas concentrations obtained by integrated distribution functions is accompanied by one of the highest risk values. The lowest risk value is provided by the boundary concentrations obtained by the minimum risk method. The method proposed for determining the boundary values of gas concentrations, taking into account the influence of the most relevant factors, allows significantly lower the values of possible risks and consequently can increase the operational reliability of high-voltage transformers, especially those that are used outside the normative service life.","PeriodicalId":35639,"journal":{"name":"Energetika","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energetika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6001/ENERGETIKA.V64I3.3806","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Earth and Planetary Sciences","Score":null,"Total":0}
引用次数: 1
Abstract
The aim of the scientific research provided in the article is to increase the operational reliability of high-voltage power transformers by reducing the possible risks when diagnosing high-voltage equipment based on the analysis of gases dissolved in oil. We described the method for determining the boundary (typical) gas concentrations by the integral function method, which is recommended by some existing standards, and the author’s method for determining the boundary concentrations of gases ensuring a minimum of possible economic damage in case of taking erroneous decisions. The analysis of boundary concentrations of gases obtained by the method of integral functions and the method of minimum risk showed that boundary values differ significantly for the same data, depending on the method of determination. To determine the reliability of decision-making we used a comparative analysis of risk values that may arise while making a diagnosis of high-voltage transformers based on the analysis of gases dissolved in oil, the boundary values of gas concentrations obtained by the integral function method and the minimum risk method, as well as the boundary values of gas concentrations regulated by known international and national standards were used. The study has revealed that the use of typical values of gas concentrations obtained by integrated distribution functions is accompanied by one of the highest risk values. The lowest risk value is provided by the boundary concentrations obtained by the minimum risk method. The method proposed for determining the boundary values of gas concentrations, taking into account the influence of the most relevant factors, allows significantly lower the values of possible risks and consequently can increase the operational reliability of high-voltage transformers, especially those that are used outside the normative service life.
EnergetikaEnergy-Energy Engineering and Power Technology
CiteScore
2.10
自引率
0.00%
发文量
0
期刊介绍:
The journal publishes original scientific, review and problem papers in the following fields: power engineering economics, modelling of energy systems, their management and optimization, target systems, environmental impacts of power engineering objects, nuclear energetics, its safety, radioactive waste disposal, renewable power sources, power engineering metrology, thermal physics, aerohydrodynamics, plasma technologies, combustion processes, hydrogen energetics, material studies and technologies, hydrology, hydroenergetics. All papers are reviewed. Information is presented on the defended theses, various conferences, reviews, etc.