Evaluation of Friction and Surface Characteristics of Two Types of Self-Ligating Bracket Gate: An In Vitro Study

IF 0.6 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
A. Ibrahim, H. Kanbar, D. Obaid
{"title":"Evaluation of Friction and Surface Characteristics of Two Types of Self-Ligating Bracket Gate: An In Vitro Study","authors":"A. Ibrahim, H. Kanbar, D. Obaid","doi":"10.4103/denthyp.denthyp_34_22","DOIUrl":null,"url":null,"abstract":"Introduction: Frictional forces generation during orthodontic treatment with fixed appliances impedes appropriate tooth movement; hence, research is ongoing to explore “frictionless” techniques. This in vitro study compares Damon Q and Pactive self-ligating metallic brackets in terms of friction and surface characteristics of the bracket gates when using CuNiTi archwires during leveling and alignment stage and examines the effects of aging conditions on frictional force generation. Methods: A total of 108 metallic self-ligating brackets (Damon Q and Pactive) were investigated for frictional resistance with round 0.014″ and rectangular 0.014″∗0.025″ CuNiTi archwires post exposure to water storage and acidic attack aging conditions. The bracket gate surface characteristics were evaluated using scanning electron microscope (SEM). Results: There was no statistically significant difference (P > 0.05) in friction generation between the two bracket systems when coupled with 0.014″ CuNiTi archwire, but the Pactive brackets yielded significantly higher frictional forces (P < 0.05) when coupled with 0.014″∗0.025″ archwire. The SEM findings revealed nonsignificant differences (P > 0.05) between the surface characteristics of the bracket gates. Conclusions: Damon Q brackets generate low frictional forces, suggesting better performance than Pactive brackets during the first phase of orthodontic treatment. A modified scoring system was developed for an objective description of bracket surface characteristics.","PeriodicalId":43354,"journal":{"name":"Dental Hypotheses","volume":"13 1","pages":"27 - 35"},"PeriodicalIF":0.6000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Hypotheses","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/denthyp.denthyp_34_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Frictional forces generation during orthodontic treatment with fixed appliances impedes appropriate tooth movement; hence, research is ongoing to explore “frictionless” techniques. This in vitro study compares Damon Q and Pactive self-ligating metallic brackets in terms of friction and surface characteristics of the bracket gates when using CuNiTi archwires during leveling and alignment stage and examines the effects of aging conditions on frictional force generation. Methods: A total of 108 metallic self-ligating brackets (Damon Q and Pactive) were investigated for frictional resistance with round 0.014″ and rectangular 0.014″∗0.025″ CuNiTi archwires post exposure to water storage and acidic attack aging conditions. The bracket gate surface characteristics were evaluated using scanning electron microscope (SEM). Results: There was no statistically significant difference (P > 0.05) in friction generation between the two bracket systems when coupled with 0.014″ CuNiTi archwire, but the Pactive brackets yielded significantly higher frictional forces (P < 0.05) when coupled with 0.014″∗0.025″ archwire. The SEM findings revealed nonsignificant differences (P > 0.05) between the surface characteristics of the bracket gates. Conclusions: Damon Q brackets generate low frictional forces, suggesting better performance than Pactive brackets during the first phase of orthodontic treatment. A modified scoring system was developed for an objective description of bracket surface characteristics.
两种自结扎支架门的摩擦和表面特性的体外研究
引言:固定矫治器正畸治疗过程中产生的摩擦力阻碍了牙齿的适当运动;因此,探索“无摩擦”技术的研究正在进行中。本体外研究比较了Damon Q和Pacive自锁金属托槽在调平和对齐阶段使用CuNiTi弓丝时托槽门的摩擦和表面特性,并考察了老化条件对摩擦力产生的影响。方法:采用圆形0.014〃和矩形0.014〃*0.025〃CuNiTi弓丝,对108个金属自锁托槽(Damon Q和Pactive)在蓄水和酸性侵蚀老化条件下的摩擦阻力进行了研究。使用扫描电子显微镜(SEM)评估支架栅极的表面特性。结果:差异无统计学意义(P > 0.05),但Pacive托槽产生的摩擦力明显更高(P  0.05)之间。结论:在正畸治疗的第一阶段,Damon Q托槽产生的摩擦力较低,表明其性能优于Pacive托槽。为了客观描述托槽表面特征,开发了一种改进的评分系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Dental Hypotheses
Dental Hypotheses DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.00
自引率
0.00%
发文量
16
审稿时长
21 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信