{"title":"Numerical investigations on post-fire bond behaviour of reinforcement in concrete","authors":"Arunita Das, J. Bošnjak, Akanshu Sharma","doi":"10.21809/RILEMTECHLETT.2019.88","DOIUrl":null,"url":null,"abstract":"Reinforced concrete (RC) structures may be subjected to accidental fire loads during their service life. In such a case, it is essential to have appropriate methods for the estimation of post-fire performance. One of the vital aspects for the performance of RC structures is adequate steel-to-concrete bond. The bond behaviour under ambient conditions is very well established. However, an appropriate model for the assessment of the post-fire bond capacity is still lacking. In order to provide more insight into the bond performance after fire, a 3D FE numerical study using a thermo-mechanical model with temperature dependent microplane model for concrete is performed. The effects of concrete cover, confinement through stirrups, fire duration and exposure type on post-fire bond performance are investigated using beam-end specimen. The results show a strong degradation of post-fire bond capacity, which is primarily attributed to the irreversible damage of concrete cover resulting from heating and cooling.","PeriodicalId":36420,"journal":{"name":"RILEM Technical Letters","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RILEM Technical Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21809/RILEMTECHLETT.2019.88","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 4
Abstract
Reinforced concrete (RC) structures may be subjected to accidental fire loads during their service life. In such a case, it is essential to have appropriate methods for the estimation of post-fire performance. One of the vital aspects for the performance of RC structures is adequate steel-to-concrete bond. The bond behaviour under ambient conditions is very well established. However, an appropriate model for the assessment of the post-fire bond capacity is still lacking. In order to provide more insight into the bond performance after fire, a 3D FE numerical study using a thermo-mechanical model with temperature dependent microplane model for concrete is performed. The effects of concrete cover, confinement through stirrups, fire duration and exposure type on post-fire bond performance are investigated using beam-end specimen. The results show a strong degradation of post-fire bond capacity, which is primarily attributed to the irreversible damage of concrete cover resulting from heating and cooling.