Accelerometers-Embedded Lycra Sleeves to Test Wear Compliance and Upper-Limb Activity in People with Stroke: A Feasibility Study

IF 0.4 Q4 ORTHOPEDICS
Praveen Kumar, Jason Leake, S. Brodie, Jennifer Molton, Rosie O'Reilly, A. Pearce, Jade Steele, P. Caleb-Solly
{"title":"Accelerometers-Embedded Lycra Sleeves to Test Wear Compliance and Upper-Limb Activity in People with Stroke: A Feasibility Study","authors":"Praveen Kumar, Jason Leake, S. Brodie, Jennifer Molton, Rosie O'Reilly, A. Pearce, Jade Steele, P. Caleb-Solly","doi":"10.1097/JPO.0000000000000406","DOIUrl":null,"url":null,"abstract":"ABSTRACT Introduction To establish a possible effect of Lycra sleeves, accurate recording of wear time is critical. The aim of this study was to test whether an accelerometer-embedded Lycra sleeve can measure wear compliance and record upper-limb (UL) movements/activity in people with stroke. Methods Seven adults with stroke resulting in unilateral UL weakness were approached for participation in this study as a convenience sample, and five participants were recruited. Participants wore accelerometer-embedded Lycra sleeve on their affected arm for 8 to 10 hrs/d for 14 days and were prescribed four simple UL exercises. They completed a diary to record daily sleeve wear time and exercise times. Upper-limb function, shoulder muscle strength, range of movement, and pain were assessed at days 1 and 14. Results Seven participants were approached, and five participants (72 ± 10 years) were recruited. The mean time since stroke was 20 months. Using an acceleration movement threshold of 0.01 g (g = acceleration of gravity) and the constructed algorithm, the sleeve donning and doffing time was identified. The mean accelerometer and diary-recorded wear time were 11.64 hrs/d (SD, 2.64) and 11.27 hrs/d (SD, 2.03), respectively. Individual spikes above threshold indicated UL activity but could not distinguish participant-recorded exercises from daily UL use. Arm function showed improvement in three of five participants. Conclusions Accelerometers provide a practical method to record wear time of a Lycra sleeve, overcoming the necessity for patients to keep diaries, which can often be unreliable. A more sensitive accelerometer that can detect the direction of the acceleration and movement should be considered in future studies. Clinical Relevance Accelerometers provide accurate data on Lycra sleeve wear time and may help with monitoring adherence.","PeriodicalId":53702,"journal":{"name":"Journal of Prosthetics and Orthotics","volume":"35 1","pages":"122 - 128"},"PeriodicalIF":0.4000,"publicationDate":"2021-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetics and Orthotics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/JPO.0000000000000406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

ABSTRACT Introduction To establish a possible effect of Lycra sleeves, accurate recording of wear time is critical. The aim of this study was to test whether an accelerometer-embedded Lycra sleeve can measure wear compliance and record upper-limb (UL) movements/activity in people with stroke. Methods Seven adults with stroke resulting in unilateral UL weakness were approached for participation in this study as a convenience sample, and five participants were recruited. Participants wore accelerometer-embedded Lycra sleeve on their affected arm for 8 to 10 hrs/d for 14 days and were prescribed four simple UL exercises. They completed a diary to record daily sleeve wear time and exercise times. Upper-limb function, shoulder muscle strength, range of movement, and pain were assessed at days 1 and 14. Results Seven participants were approached, and five participants (72 ± 10 years) were recruited. The mean time since stroke was 20 months. Using an acceleration movement threshold of 0.01 g (g = acceleration of gravity) and the constructed algorithm, the sleeve donning and doffing time was identified. The mean accelerometer and diary-recorded wear time were 11.64 hrs/d (SD, 2.64) and 11.27 hrs/d (SD, 2.03), respectively. Individual spikes above threshold indicated UL activity but could not distinguish participant-recorded exercises from daily UL use. Arm function showed improvement in three of five participants. Conclusions Accelerometers provide a practical method to record wear time of a Lycra sleeve, overcoming the necessity for patients to keep diaries, which can often be unreliable. A more sensitive accelerometer that can detect the direction of the acceleration and movement should be considered in future studies. Clinical Relevance Accelerometers provide accurate data on Lycra sleeve wear time and may help with monitoring adherence.
加速计-嵌入莱卡袖测试中风患者的穿戴依从性和上肢活动:可行性研究
为了确定莱卡袖的可能效果,准确记录穿着时间至关重要。本研究的目的是测试一个内置加速计的莱卡套筒是否可以测量中风患者的佩戴依从性并记录上肢运动/活动。方法选取7例成人卒中单侧UL无力患者作为方便样本,共招募5例。参与者在他们受影响的手臂上穿着嵌入了加速计的莱卡套筒,每天8到10小时,持续14天,并规定了四种简单的UL练习。他们完成了一份日记,记录每天穿袖子的时间和锻炼的时间。在第1天和第14天评估上肢功能、肩部肌肉力量、活动范围和疼痛。结果共接触7例受试者,共招募5例(72±10岁)。中风后的平均时间是20个月。采用加速度运动阈值为0.01 g (g =重力加速度)和构造的算法,确定了套筒的穿落时间。加速度计和日记记录的平均磨损时间分别为11.64小时/天(SD值为2.64)和11.27小时/天(SD值为2.03)。个别峰值高于阈值表明UL活动,但不能区分参与者记录的锻炼和日常UL使用。五名参与者中有三人的手臂功能有所改善。结论加速度计提供了一种实用的方法来记录莱卡套袖的穿着时间,克服了患者需要记录日记的缺点。在未来的研究中应该考虑一种更灵敏的加速度计,可以检测加速度和运动的方向。临床相关性加速度计提供莱卡套筒佩戴时间的准确数据,并可能有助于监测依从性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetics and Orthotics
Journal of Prosthetics and Orthotics Medicine-Rehabilitation
CiteScore
1.30
自引率
16.70%
发文量
59
期刊介绍: Published quarterly by the AAOP, JPO: Journal of Prosthetics and Orthotics provides information on new devices, fitting and fabrication techniques, and patient management experiences. The focus is on prosthetics and orthotics, with timely reports from related fields such as orthopaedic research, occupational therapy, physical therapy, orthopaedic surgery, amputation surgery, physical medicine, biomedical engineering, psychology, ethics, and gait analysis. Each issue contains research-based articles reviewed and approved by a highly qualified editorial board and an Academy self-study quiz offering two PCE''s.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信