Functional outcome of distal end radius fractures managed with variable-angle locking plates: A prospective study

Manikandan Kumarasamy, K. Kumar, A. Akashdeep, K. Uma Anand
{"title":"Functional outcome of distal end radius fractures managed with variable-angle locking plates: A prospective study","authors":"Manikandan Kumarasamy, K. Kumar, A. Akashdeep, K. Uma Anand","doi":"10.4103/jodp.jodp_7_22","DOIUrl":null,"url":null,"abstract":"Introduction: Management of distal end radius intraarticular fractures is difficult to manage and these fractures account for 10% of all fractures. Multiple treatment options ranging from conservative to internal fixation, of which volar plate fixation has emerged as an effective method of internal fixation in comparison with other fixed-angle locking plates as they ensure proper restoration of the articular surfaces and anatomical alignment. Materials and Methods: A hospital-based prospective study was conducted on 14 patients with distal end radius fractures admitted in our hospital from January 2019 to December 2019. Patients with distal end radius fractures treated with variable-angle locking plate were included and were followed-up minimum of 6 months. The results were analyzed based on radiological parameters and Mayo Wrist Score (MWS). Results: Of 14 patients, 11 were male patients and three were female patients. Seven patients had right-sided fracture whereas remaining seven patients had left-sided fractures. All 14 patients were treated with variable-angle locking plate. Among 14 patients, 12 patients achieved union by 12 weeks, only two patients achieved union by 24 weeks. Ten patients had excellent results while four patients had a good outcome based on MWS. All patients in our study had painless union without any complications. Conclusion: The use of variable-angle locking plates in distal end radius fractures helps to maintain perfect anatomical reduction, early mobilization, and better postoperative outcome.","PeriodicalId":34809,"journal":{"name":"Journal of Orthopaedic Diseases and Traumatology","volume":"5 1","pages":"132 - 137"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Diseases and Traumatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jodp.jodp_7_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Management of distal end radius intraarticular fractures is difficult to manage and these fractures account for 10% of all fractures. Multiple treatment options ranging from conservative to internal fixation, of which volar plate fixation has emerged as an effective method of internal fixation in comparison with other fixed-angle locking plates as they ensure proper restoration of the articular surfaces and anatomical alignment. Materials and Methods: A hospital-based prospective study was conducted on 14 patients with distal end radius fractures admitted in our hospital from January 2019 to December 2019. Patients with distal end radius fractures treated with variable-angle locking plate were included and were followed-up minimum of 6 months. The results were analyzed based on radiological parameters and Mayo Wrist Score (MWS). Results: Of 14 patients, 11 were male patients and three were female patients. Seven patients had right-sided fracture whereas remaining seven patients had left-sided fractures. All 14 patients were treated with variable-angle locking plate. Among 14 patients, 12 patients achieved union by 12 weeks, only two patients achieved union by 24 weeks. Ten patients had excellent results while four patients had a good outcome based on MWS. All patients in our study had painless union without any complications. Conclusion: The use of variable-angle locking plates in distal end radius fractures helps to maintain perfect anatomical reduction, early mobilization, and better postoperative outcome.
可变角度锁定钢板治疗桡骨远端骨折的功能结局:一项前瞻性研究
桡骨远端关节内骨折的治疗比较困难,这类骨折占所有骨折的10%。从保守到内固定有多种治疗选择,与其他固定角度锁定钢板相比,掌侧钢板固定已成为一种有效的内固定方法,因为它们可确保关节表面的适当恢复和解剖对齐。材料与方法:对2019年1月至2019年12月我院收治的14例桡骨远端骨折患者进行前瞻性研究。采用可变角度锁定钢板治疗桡骨远端骨折的患者纳入研究,随访至少6个月。根据放射学参数和梅奥手腕评分(MWS)对结果进行分析。结果:14例患者中,男性11例,女性3例。7例为右侧骨折,其余7例为左侧骨折。所有14例患者均采用可变角度锁定钢板治疗。14例患者中12例12周愈合,仅有2例24周愈合。10例患者预后良好,4例患者预后良好。本研究所有患者均无痛愈合,无并发症。结论:在桡骨远端骨折中使用可变角度锁定钢板有助于保持完美的解剖复位,早期活动,术后效果较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
26
审稿时长
17 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书