Changes in corneal properties and its effect on intraocular pressure measurement following phacoemulsification with intraocular lens implantation with or without trabeculectomy
{"title":"Changes in corneal properties and its effect on intraocular pressure measurement following phacoemulsification with intraocular lens implantation with or without trabeculectomy","authors":"Ashim Dey, R. David, R. Asokan, R. George","doi":"10.35119/asjoo.v16i1.344","DOIUrl":null,"url":null,"abstract":"Purpose: To evaluate the changes incorneal biomechanical properties and their effect on pre and postoperative differences in IOP measurement by each tonometer \nDesign: Observational study. \nMethods: The study was done in subjects who underwent phacoemulsification with intraocular lens (IOL) implantation (phaco-IOL) and combined phacoemulsification with IOL implantation and trabeculectomy (phaco-trab). IOP was measured by a single trained examiner using rebound tonometer (RBT), Ocular Response Analyzer (ORA), Goldmann applanation tonometer (GAT), dynamic contour tonometer (DCT), and Tono-Pen. Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured using ORA, central corneal thickness (CCT) using ultrasonic pachymeter, and corneal curvature (CR) with manual keratometry. All measurements were done one week prior to surgery and after four weeks and six weeks of the two surgeries, respectively. Only the operated eye was included for analysis. \nResults: Twenty-nine eyes of 29 normal subjects who underwent phaco-IOL and 23 eyes of 23 glaucoma subjects who underwent phaco-trab were studied. Increase in CCT [10.2 ± 14.86 microns, p = 0.001], decrease in CH [0.82 ± 1.38 mmHg, p = 0.003] and CRF [0.97 ± 1.0 mmHg, p < 0.001] were found post-phaco-IOL, whereas post-phaco-trab decrease in CCT [16.61 ± 15.22 microns, p < 0.001], CRF [2.28 ± 1.93 mmHg, p < 0.001] with increase in CH [0.95 ± 1.89 mmHg, p = 0.03] were noted. Multiple linear regression analysis showed significant associations for change in CH and CRF with change in IOP and not with CCT and CR postoperatively. \nConclusion: Alterations in CH and CRF were associated with changes in IOP measured postoperatively by different tonometers. CH and CRF changes contribute to postoperative changes in measured IOP. \n ","PeriodicalId":39864,"journal":{"name":"Asian Journal of Ophthalmology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35119/asjoo.v16i1.344","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate the changes incorneal biomechanical properties and their effect on pre and postoperative differences in IOP measurement by each tonometer
Design: Observational study.
Methods: The study was done in subjects who underwent phacoemulsification with intraocular lens (IOL) implantation (phaco-IOL) and combined phacoemulsification with IOL implantation and trabeculectomy (phaco-trab). IOP was measured by a single trained examiner using rebound tonometer (RBT), Ocular Response Analyzer (ORA), Goldmann applanation tonometer (GAT), dynamic contour tonometer (DCT), and Tono-Pen. Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured using ORA, central corneal thickness (CCT) using ultrasonic pachymeter, and corneal curvature (CR) with manual keratometry. All measurements were done one week prior to surgery and after four weeks and six weeks of the two surgeries, respectively. Only the operated eye was included for analysis.
Results: Twenty-nine eyes of 29 normal subjects who underwent phaco-IOL and 23 eyes of 23 glaucoma subjects who underwent phaco-trab were studied. Increase in CCT [10.2 ± 14.86 microns, p = 0.001], decrease in CH [0.82 ± 1.38 mmHg, p = 0.003] and CRF [0.97 ± 1.0 mmHg, p < 0.001] were found post-phaco-IOL, whereas post-phaco-trab decrease in CCT [16.61 ± 15.22 microns, p < 0.001], CRF [2.28 ± 1.93 mmHg, p < 0.001] with increase in CH [0.95 ± 1.89 mmHg, p = 0.03] were noted. Multiple linear regression analysis showed significant associations for change in CH and CRF with change in IOP and not with CCT and CR postoperatively.
Conclusion: Alterations in CH and CRF were associated with changes in IOP measured postoperatively by different tonometers. CH and CRF changes contribute to postoperative changes in measured IOP.
目的:评价角膜生物力学特性的变化及其对各眼压计眼压测量术前和术后差异的影响。方法:采用超声乳化联合人工晶状体植入术(phao -IOL)和超声乳化联合人工晶状体植入术联合小梁切除术(phao -trab)进行研究。眼压由一名训练有素的检查人员使用反弹眼压仪(RBT)、眼反应分析仪(ORA)、Goldmann眼压仪(GAT)、动态轮廓眼压仪(DCT)和Tono-Pen测量。采用ORA法测定角膜迟滞(CH)和角膜阻力因子(CRF),超声测厚仪测定角膜中央厚度(CCT),手工测角法测定角膜曲率(CR)。所有测量分别在手术前一周、手术后4周和6周进行。只有手术后的眼睛被纳入分析。结果:对29例正常人行晶状体人工晶状体植入术的29只眼和23例青光眼行晶状体植入术的23只眼进行研究。phaco- iol后CCT升高[10.2±14.86 μ m, p = 0.001], CH降低[0.82±1.38 mmHg, p = 0.003], CRF降低[0.97±1.0 mmHg, p < 0.001],而phaco- iol后CCT降低[16.61±15.22 μ m, p < 0.001], CRF降低[2.28±1.93 mmHg, p < 0.001], CH升高[0.95±1.89 mmHg, p = 0.03]。多元线性回归分析显示,术后CH和CRF的变化与IOP的变化有显著相关性,而与CCT和CR无关。结论:术后不同眼压计测量的眼压变化与CH和CRF的改变有关。CH和CRF的改变有助于术后测量IOP的变化。
期刊介绍:
Asian Journal of OPHTHALMOLOGY is the official peer-reviewed journal of the South East Asia Glaucoma Interest Group (SEAGIG) and is indexed in EMBASE/Excerpta Medica. Asian Journal of OPHTHALMOLOGY is published quarterly (four [4] issues per year) by Scientific Communications International Limited. The journal is published on-line only and is distributed free of cost via the SEAGIG website.