{"title":"Laboratory assessment of a head impact sensor for youth soccer ball heading impacts using an anthropomorphic test device.","authors":"Declan A Patton, Colin M Huber, Ethan C Douglas, Thomas Seacrist, Kristy B Arbogast","doi":"10.1177/17543371211063124","DOIUrl":null,"url":null,"abstract":"<p><p>Recent advances in technology have enabled the development of instrumented equipment, which estimate the head impact kinematics of athletes in vivo. One such headband-mounted impact sensor is the SIM-G (Triax Technologies, Norwalk, CT, USA), which has been previously used to investigate the biomechanics of soccer heading by human subjects. Previous studies have evaluated the accuracy of the SIM-G for pure rotation and pendulum, impulse hammer and drop rig impacts. The current study used a soccer ball heading model to evaluate the accuracy of the SIM-G. A soccer ball was projected at the head of an anthropomorphic test device (ATD) representing a 10-year-old to replicate the heading maneuver at various impact sites, angles and speeds previously identified in youth soccer. Linear regression revealed that the SIM-G sensor overestimated the peak angular velocity and linear acceleration recorded by the ATD headform by approximately 44% and 105%, respectively. Tests in which the ball directly contacted the SIM-G sensor resulted in the largest peak linear accelerations. Glancing impacts were significantly associated with a decrease in percentage error of the SIM-G sensor peak angular velocity data relative to the ATD reference data. While it may not demonstrate accuracy in estimating the magnitudes of head impacts, the SIM-G remains a useful tool to provide estimates of head impact exposure for soccer players.</p>","PeriodicalId":20674,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology","volume":" ","pages":"36-43"},"PeriodicalIF":1.2000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12971084/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/17543371211063124","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/12/14 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Recent advances in technology have enabled the development of instrumented equipment, which estimate the head impact kinematics of athletes in vivo. One such headband-mounted impact sensor is the SIM-G (Triax Technologies, Norwalk, CT, USA), which has been previously used to investigate the biomechanics of soccer heading by human subjects. Previous studies have evaluated the accuracy of the SIM-G for pure rotation and pendulum, impulse hammer and drop rig impacts. The current study used a soccer ball heading model to evaluate the accuracy of the SIM-G. A soccer ball was projected at the head of an anthropomorphic test device (ATD) representing a 10-year-old to replicate the heading maneuver at various impact sites, angles and speeds previously identified in youth soccer. Linear regression revealed that the SIM-G sensor overestimated the peak angular velocity and linear acceleration recorded by the ATD headform by approximately 44% and 105%, respectively. Tests in which the ball directly contacted the SIM-G sensor resulted in the largest peak linear accelerations. Glancing impacts were significantly associated with a decrease in percentage error of the SIM-G sensor peak angular velocity data relative to the ATD reference data. While it may not demonstrate accuracy in estimating the magnitudes of head impacts, the SIM-G remains a useful tool to provide estimates of head impact exposure for soccer players.

使用拟人化测试设备对青少年足球头部撞击传感器的实验室评估
最近的技术进步使仪器设备的发展成为可能,这些设备可以估计运动员在体内的头部撞击运动学。SIM-G (Triax Technologies, Norwalk, CT, USA)就是这样一种头带式冲击传感器,它曾被用于研究人类足球头球的生物力学。之前的研究已经评估了SIM-G在纯旋转和摆锤、脉冲锤和跌落钻机冲击下的精度。本研究采用足球头球模型来评价SIM-G的准确性。一个足球被投射到一个拟人化测试装置(ATD)的头部,代表一个10岁的孩子,在不同的撞击地点、角度和速度下复制以前在青少年足球中发现的头球动作。线性回归表明,SIM-G传感器对ATD顶盖记录的峰值角速度和线性加速度分别高估了约44%和105%。在球直接接触SIM-G传感器的测试中,产生了最大的峰值线性加速度。掠射撞击与SIM-G传感器峰值角速度数据相对于ATD参考数据的百分比误差降低显著相关。虽然SIM-G在估计头部撞击的程度方面可能不准确,但它仍然是一个有用的工具,可以为足球运动员提供头部撞击暴露的估计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
20.00%
发文量
51
审稿时长
>12 weeks
期刊介绍: The Journal of Sports Engineering and Technology covers the development of novel sports apparel, footwear, and equipment; and the materials, instrumentation, and processes that make advances in sports possible.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书