The effect of the use of disinfectants during COVID-19 pandemic on the bacterial contamination of dental unit waterlines

IF 1.3 Q4 ENVIRONMENTAL SCIENCES
Neematollah Jaafarzadeh Haghighi Fard, S. Jorfi, M. Panahi Fard, Maneli Ardashir Zadeh
{"title":"The effect of the use of disinfectants during COVID-19 pandemic on the bacterial contamination of dental unit waterlines","authors":"Neematollah Jaafarzadeh Haghighi Fard, S. Jorfi, M. Panahi Fard, Maneli Ardashir Zadeh","doi":"10.34172/ehem.2022.26","DOIUrl":null,"url":null,"abstract":"Background: The emergence and spread of SARS-CoV-2 has increased environmental disinfectant usage to reduce the transmission of this virus. Ethanol 70%-90% and 5% sodium hypochlorite have the highest consumption for disinfection of various environmental surfaces during the COVID-19 pandemic. Dental unit waterlines (DUWLs) are more susceptible to microbial contamination due to their particular structure. This study aimed to investigate the effect of increasing the use of disinfectants during the COVID-19 pandemic on the bacterial contamination of DUWLs. Methods: During November (before the COVID-19 pandemic) and December (during the COVID-19 pandemic), a questionnaire was used to assess the frequency of disinfection of unit surfaces and other environmental surfaces and the type of disinfectants used. The water samples were collected from different parts of DUWLs. The gram staining method followed by the biochemical method was used to identify the desired bacteria. Results: The results showed that the frequency of disinfection of dental units increased 8 times in December compared to November. There is a significant inverse relationship between the frequency of disinfection of dental units surfaces and the bacterial contamination of DUWLs. Conclusion: The microbial load in different parts of the DUWLs was less than 200 CFU/mL. The American Dental Association (ADA) recommended and indicated the allowable microbial concentration and the appropriate quality and water used in these units.","PeriodicalId":51877,"journal":{"name":"Environmental Health Engineering and Management Journal","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2022-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Health Engineering and Management Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/ehem.2022.26","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The emergence and spread of SARS-CoV-2 has increased environmental disinfectant usage to reduce the transmission of this virus. Ethanol 70%-90% and 5% sodium hypochlorite have the highest consumption for disinfection of various environmental surfaces during the COVID-19 pandemic. Dental unit waterlines (DUWLs) are more susceptible to microbial contamination due to their particular structure. This study aimed to investigate the effect of increasing the use of disinfectants during the COVID-19 pandemic on the bacterial contamination of DUWLs. Methods: During November (before the COVID-19 pandemic) and December (during the COVID-19 pandemic), a questionnaire was used to assess the frequency of disinfection of unit surfaces and other environmental surfaces and the type of disinfectants used. The water samples were collected from different parts of DUWLs. The gram staining method followed by the biochemical method was used to identify the desired bacteria. Results: The results showed that the frequency of disinfection of dental units increased 8 times in December compared to November. There is a significant inverse relationship between the frequency of disinfection of dental units surfaces and the bacterial contamination of DUWLs. Conclusion: The microbial load in different parts of the DUWLs was less than 200 CFU/mL. The American Dental Association (ADA) recommended and indicated the allowable microbial concentration and the appropriate quality and water used in these units.
新冠肺炎大流行期间使用消毒剂对牙科设备水线细菌污染的影响
背景:严重急性呼吸系统综合征冠状病毒2型的出现和传播增加了环境消毒剂的使用,以减少这种病毒的传播。在新冠肺炎大流行期间,乙醇70%-90%和5%的次氯酸钠用于各种环境表面的消毒消耗量最高。牙科单元水线(DUWL)由于其特殊的结构而更容易受到微生物污染。本研究旨在调查新冠肺炎大流行期间增加消毒剂使用对DUWLs细菌污染的影响。方法:在11月(新冠肺炎大流行之前)和12月(新冠肺炎大流行期间),使用问卷调查来评估单元表面和其他环境表面的消毒频率以及使用的消毒剂类型。从DUWLs的不同部分采集了水样。采用革兰氏染色法和生化法对所需细菌进行鉴定。结果:结果显示,12月牙科病房的消毒频率比11月增加了8倍。牙科单元表面的消毒频率与DUWL的细菌污染之间存在显著的反比关系。结论:DUWLs不同部位的微生物载量均小于200 CFU/mL。美国牙科协会(ADA)建议并指出了允许的微生物浓度以及这些装置中使用的适当质量和水。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.40
自引率
37.50%
发文量
17
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信