Control performance of sloped rolling-type isolators designed with stepwise variable parameters

IF 2.1 3区 工程技术 Q2 ENGINEERING, CIVIL
Shiang‐Jung Wang, Yi-Lin Sung
{"title":"Control performance of sloped rolling-type isolators designed with stepwise variable parameters","authors":"Shiang‐Jung Wang, Yi-Lin Sung","doi":"10.12989/SSS.2021.27.6.1011","DOIUrl":null,"url":null,"abstract":"With the same horizontal acceleration control performance, the horizontal displacement control performances of sloped rolling-type seismic isolators passively provided with stepwise variable parameters, as well as constant ones, are numerically investigated in this study. The first design possesses a smaller sloping angle with larger damping force at smaller horizontal isolation displacement and a larger sloping angle with smaller damping force at larger horizontal isolation displacement. In other words, this design has stepwise increased sloping angles and stepwise decreased damping force with increasing horizontal isolation displacement. The second design has an opposite design philosophy to the first one, i.e., it has stepwise decreased sloping angles and stepwise increased damping force with increasing horizontal isolation displacement. A series of numerical results present that for sloped rolling-type seismic isolators designed with a constant sloping angle and damping force, in general, the larger the damping force (in other words, the smaller the sloping angle), the smaller and the larger the horizontal maximum and residual displacement responses presented, respectively. The first and second designs with stepwise variable parameters each have its advantage for suppressing horizontal isolation displacement under far-field and pulse-like near-fault ground motions because of their larger energy dissipation capabilities designed at different stages. When the horizontal isolation displacement responses at the end of ground motions are still within the first slope rolling range with a larger sloping angle of the second design, as expected, adopting the second design can exhibit a better re-centering performance than adopting the first design. To have acceptable displacement control performances and without scarifying acceleration control performances under diverse seismic demands, compared with adopting the designs with constant parameters and the first design, adopting the second design could be an alternative solution and better choice.","PeriodicalId":51155,"journal":{"name":"Smart Structures and Systems","volume":"27 1","pages":"1011"},"PeriodicalIF":2.1000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Smart Structures and Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.12989/SSS.2021.27.6.1011","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 2

Abstract

With the same horizontal acceleration control performance, the horizontal displacement control performances of sloped rolling-type seismic isolators passively provided with stepwise variable parameters, as well as constant ones, are numerically investigated in this study. The first design possesses a smaller sloping angle with larger damping force at smaller horizontal isolation displacement and a larger sloping angle with smaller damping force at larger horizontal isolation displacement. In other words, this design has stepwise increased sloping angles and stepwise decreased damping force with increasing horizontal isolation displacement. The second design has an opposite design philosophy to the first one, i.e., it has stepwise decreased sloping angles and stepwise increased damping force with increasing horizontal isolation displacement. A series of numerical results present that for sloped rolling-type seismic isolators designed with a constant sloping angle and damping force, in general, the larger the damping force (in other words, the smaller the sloping angle), the smaller and the larger the horizontal maximum and residual displacement responses presented, respectively. The first and second designs with stepwise variable parameters each have its advantage for suppressing horizontal isolation displacement under far-field and pulse-like near-fault ground motions because of their larger energy dissipation capabilities designed at different stages. When the horizontal isolation displacement responses at the end of ground motions are still within the first slope rolling range with a larger sloping angle of the second design, as expected, adopting the second design can exhibit a better re-centering performance than adopting the first design. To have acceptable displacement control performances and without scarifying acceleration control performances under diverse seismic demands, compared with adopting the designs with constant parameters and the first design, adopting the second design could be an alternative solution and better choice.
逐步变参数斜辊式隔振器的控制性能
在水平加速度控制性能相同的情况下,对被动提供逐步变参数和固定参数的倾斜滚动式隔震器的水平位移控制性能进行了数值研究。第一种设计在较小的水平隔震位移下具有较小的斜角和较大的阻尼力,在较大的水平隔震位移下具有较大的斜角和较小的阻尼力。也就是说,随着水平隔震位移的增大,该设计的倾斜角度逐步增大,阻尼力逐步减小。第二种设计与第一种设计理念相反,即随着水平隔震位移的增大,坡角逐步减小,阻尼力逐步增大。一系列数值计算结果表明,在坡角和阻尼力不变的情况下,一般情况下,阻尼力越大(即坡角越小),其水平最大位移响应越小,剩余位移响应越大。由于在不同阶段设计了更大的能量耗散能力,第一种和第二种逐步变参数设计在抑制远场和脉冲式近断层地震动下的水平隔离位移方面各有优势。当地震动末端水平隔震位移响应仍在第一坡滚动范围内,且第二种设计的倾斜角度较大时,采用第二种设计可以比采用第一种设计表现出更好的再定心性能。为了在不影响不同地震要求下的位移控制性能和加速度控制性能,与采用不变参数设计和第一种设计相比,采用第二种设计可能是一种替代方案和更好的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Smart Structures and Systems
Smart Structures and Systems 工程技术-工程:机械
CiteScore
6.50
自引率
8.60%
发文量
0
审稿时长
9 months
期刊介绍: An International Journal of Mechatronics, Sensors, Monitoring, Control, Diagnosis, and Management airns at providing a major publication channel for researchers in the general area of smart structures and systems. Typical subjects considered by the journal include: Sensors/Actuators(Materials/devices/ informatics/networking) Structural Health Monitoring and Control Diagnosis/Prognosis Life Cycle Engineering(planning/design/ maintenance/renewal) and related areas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信