{"title":"Design of an Ultrasonic Transducer Encapsulation for High-Temperature Applications","authors":"Mina Torabi Milani, Jenna Del Fatti, Kimberley Orna, Yixin Zhang, A. Sinclair","doi":"10.32548/2023.me-04314","DOIUrl":null,"url":null,"abstract":"A novel approach to designing the encapsulation for a high-temperature ultrasonic transducer to be capable of continuous operation over a temperature range of 25 to 650 °C is proposed. The transducer’s active element is a heavily damped lithium niobate disc of 3 MHz resonance frequency, operating in pulse-echo mode. The initial encapsulation design is developed based on the geometrical, thermal, mechanical, electrical, and ultrasonic requirements. Two finite element modeling systems are developed to analyze the thermal-induced stresses in the transducer at low and high temperatures as well as its ultrasonic performance. The simulation results are used to optimize the design before manufacturing a transducer prototype. The prototype is tested at room and elevated temperatures to verify performance.","PeriodicalId":49876,"journal":{"name":"Materials Evaluation","volume":" ","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials Evaluation","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.32548/2023.me-04314","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0
Abstract
A novel approach to designing the encapsulation for a high-temperature ultrasonic transducer to be capable of continuous operation over a temperature range of 25 to 650 °C is proposed. The transducer’s active element is a heavily damped lithium niobate disc of 3 MHz resonance frequency, operating in pulse-echo mode. The initial encapsulation design is developed based on the geometrical, thermal, mechanical, electrical, and ultrasonic requirements. Two finite element modeling systems are developed to analyze the thermal-induced stresses in the transducer at low and high temperatures as well as its ultrasonic performance. The simulation results are used to optimize the design before manufacturing a transducer prototype. The prototype is tested at room and elevated temperatures to verify performance.
期刊介绍:
Materials Evaluation publishes articles, news and features intended to increase the NDT practitioner’s knowledge of the science and technology involved in the field, bringing informative articles to the NDT public while highlighting the ongoing efforts of ASNT to fulfill its mission. M.E. is a peer-reviewed journal, relying on technicians and researchers to help grow and educate its members by providing relevant, cutting-edge and exclusive content containing technical details and discussions. The only periodical of its kind, M.E. is circulated to members and nonmember paid subscribers. The magazine is truly international in scope, with readers in over 90 nations. The journal’s history and archive reaches back to the earliest formative days of the Society.