A Comparison of Gamma Irradiation Response Models of Bovine Blood, Liver and Kidney Tissues at Radiofrequency

T. Sombo, E. Agba, T. Ige, T. Igbawua, T. S. Azande, E. R. Nyatso, I. S. Aondoakaa, T. J. Shivil
{"title":"A Comparison of Gamma Irradiation Response Models of Bovine Blood, Liver and Kidney Tissues at Radiofrequency","authors":"T. Sombo, E. Agba, T. Ige, T. Igbawua, T. S. Azande, E. R. Nyatso, I. S. Aondoakaa, T. J. Shivil","doi":"10.4236/ojbiphy.2018.83013","DOIUrl":null,"url":null,"abstract":"This study is aimed at identifying gamma irradiated response of bovine blood, liver and kidney tissues at radiofrequency. For this purpose, impedence meter (Booton 7200) working in conjunction with signal generators (Loadster, SG416013 and Harris G857993) and improvised parallel plate dielectric cells constructed in line with the method of Laogun et al., (2005) were used to obtain the dielectric spread parameter gamma radiation α, of blood, liver and kidney tissues exposed to gamma irradiation dose range of 1.0 - 85.0 Gy. The dielectric spread parameter α gives the extent of damage induced in an irradiated tissue. Results of this work revealed that at 0 - 50 MHz frequency range, Kidney tissues displayed higher sensitive, followed Liver tissues and lasted the bovine blood between 0 - 60 Gy but reversed for blood and liver at 85 Gy. At 0 - 100 kHz frequency range liver tissue is more venerable to radiation injuries between gamma irradiation dose range of 0 - 20 Gy while between 43 - 85 Gy the Kidney’s sensitivity is the highest followed by blood and liver tissues. This implies that the liver tissues are less liable to radiation injuries at radiofrequency. A comparison of the linear, exponential and polynomial models using Akaike Information Criteria (AIC) revealed that linear models were the most suitable models for describing the effect of gamma radiation on the dielectric dispersion properties of bovine tissues at low and high radiofrequencies. This implies that the response of the investigated tissues increases linearly with gamma irradiation dose.","PeriodicalId":59528,"journal":{"name":"生物物理学期刊(英文)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"生物物理学期刊(英文)","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.4236/ojbiphy.2018.83013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study is aimed at identifying gamma irradiated response of bovine blood, liver and kidney tissues at radiofrequency. For this purpose, impedence meter (Booton 7200) working in conjunction with signal generators (Loadster, SG416013 and Harris G857993) and improvised parallel plate dielectric cells constructed in line with the method of Laogun et al., (2005) were used to obtain the dielectric spread parameter gamma radiation α, of blood, liver and kidney tissues exposed to gamma irradiation dose range of 1.0 - 85.0 Gy. The dielectric spread parameter α gives the extent of damage induced in an irradiated tissue. Results of this work revealed that at 0 - 50 MHz frequency range, Kidney tissues displayed higher sensitive, followed Liver tissues and lasted the bovine blood between 0 - 60 Gy but reversed for blood and liver at 85 Gy. At 0 - 100 kHz frequency range liver tissue is more venerable to radiation injuries between gamma irradiation dose range of 0 - 20 Gy while between 43 - 85 Gy the Kidney’s sensitivity is the highest followed by blood and liver tissues. This implies that the liver tissues are less liable to radiation injuries at radiofrequency. A comparison of the linear, exponential and polynomial models using Akaike Information Criteria (AIC) revealed that linear models were the most suitable models for describing the effect of gamma radiation on the dielectric dispersion properties of bovine tissues at low and high radiofrequencies. This implies that the response of the investigated tissues increases linearly with gamma irradiation dose.
牛血液、肝脏和肾脏组织射频辐射响应模型的比较
本研究旨在鉴定牛血液、肝脏和肾脏组织在射频下的伽玛辐射反应。为此,使用阻抗计(Booton 7200)与信号发生器(Loadster, SG416013和Harris G857993)以及按照Laogun等人(2005)的方法构建的简易平行平板介电细胞一起工作,获得了1.0 - 85.0 Gy γ辐射剂量范围下血液、肝脏和肾脏组织的介电扩散参数γ辐射α。介电扩散参数α给出了在辐照组织中引起的损伤程度。结果表明,在0 ~ 50 MHz频率范围内,肾脏组织表现出更高的敏感性,其次是肝脏组织,在0 ~ 60 Gy范围内持续,而在85 Gy范围内血液和肝脏则相反。在0 - 100千赫频率范围内,肝组织更容易受到辐射损伤,辐照剂量范围为0 - 20戈瑞,而在43 - 85戈瑞之间,肾脏的敏感性最高,其次是血液和肝脏组织。这意味着肝组织不太容易受到射频辐射损伤。利用赤池信息准则(Akaike Information Criteria, AIC)对线性模型、指数模型和多项式模型进行了比较,结果表明线性模型最适合描述伽马辐射对牛组织在低、高频下介电色散特性的影响。这意味着所研究组织的反应随辐照剂量线性增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
128
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信