HPB P35 Fluorescence guided resection of Liver Tumours: Same day administration of indocyanine green with SPY- Colour Segmented Fluorescence imaging to identify tumours intra-operatively

IF 9.4 1区 医学 Q1 SURGERY
R. Karmarkar, A.J. Benjafield, S. Aroori
{"title":"HPB P35 Fluorescence guided resection of Liver Tumours: Same day administration of indocyanine green with SPY- Colour Segmented Fluorescence imaging to identify tumours intra-operatively","authors":"R. Karmarkar, A.J. Benjafield, S. Aroori","doi":"10.1093/bjs/znac404.130","DOIUrl":null,"url":null,"abstract":"\n \n \n Indocyanine green (ICG) fluorescence imaging is a real-time navigation tool that has shown promising liver surgery results. Several regimes have been described regarding optimum timing and dose of ICG administration. Visually different fluorescent enhancement patterns correlate with different pathologies to aid the identification of lesions intra-operatively. This study aims to present our experience with using the Colour Segmented Fluorescence (CSF) model and same-day administration of low dose ICG in the resection of liver tumours.\n \n \n \n We present a single surgeon (SA) experience using indocyanine green fluorescence image-guided surgery (I-FIGS) at University Hospitals Plymouth, UK. I-FIGS was used between November 2020 and March 2022 in 15 patients with suspected liver tumours. ICG was administered intravenously at a dose of 0.02 to 0.03 mg/kg IV 2–3 hours prior to liver surgery. Using the SPY CSF mode, the image is scaled to NIRF fluorescence intensity to identify the liver tumours and their margins intra-operatively.\n \n \n \n A total of fifteen patients (eight males) with a median age of 71 years (36–86) underwent I-FIGS during the study period. Of these, 67% underwent laparoscopic liver surgery, 78% underwent non-anatomical resections, and 33% underwent re-do liver surgery. The average size of the tumour was 40.6 mm, and median number of tumours was one. All lesions were visible in CSF mode, and all had a signet ring appearance. The histology of the tumours confirmed a well to moderately differentiated colorectal metastasis in 13 (86%) patients and hepatoma in two patients. R0 resection was achieved in 11 (76%) of patients. In two patients with R1 resection, the tumour was right on the right hepatic vein, and R0 would not have been possible. The resection margins were clear in two other patients but <1mm. The overall false positive rate in our experience with I-FIGS was 3%.\n \n \n \n In our limited experience, low-dose ICG administered at least 2–3 hours prior to surgery can accurately identify liver tumours and their margins in CSF mode. Superficially located lesions are easily identifiable under CSF mode, and CSF mode helped us identify the lesions and mark the resection margin. The use of ICG is an important advancement in liver surgery, and further research is needed to optimise image interpretation and correlate with clinical resection outcomes.\n","PeriodicalId":136,"journal":{"name":"British Journal of Surgery","volume":" ","pages":""},"PeriodicalIF":9.4000,"publicationDate":"2022-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/bjs/znac404.130","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Indocyanine green (ICG) fluorescence imaging is a real-time navigation tool that has shown promising liver surgery results. Several regimes have been described regarding optimum timing and dose of ICG administration. Visually different fluorescent enhancement patterns correlate with different pathologies to aid the identification of lesions intra-operatively. This study aims to present our experience with using the Colour Segmented Fluorescence (CSF) model and same-day administration of low dose ICG in the resection of liver tumours. We present a single surgeon (SA) experience using indocyanine green fluorescence image-guided surgery (I-FIGS) at University Hospitals Plymouth, UK. I-FIGS was used between November 2020 and March 2022 in 15 patients with suspected liver tumours. ICG was administered intravenously at a dose of 0.02 to 0.03 mg/kg IV 2–3 hours prior to liver surgery. Using the SPY CSF mode, the image is scaled to NIRF fluorescence intensity to identify the liver tumours and their margins intra-operatively. A total of fifteen patients (eight males) with a median age of 71 years (36–86) underwent I-FIGS during the study period. Of these, 67% underwent laparoscopic liver surgery, 78% underwent non-anatomical resections, and 33% underwent re-do liver surgery. The average size of the tumour was 40.6 mm, and median number of tumours was one. All lesions were visible in CSF mode, and all had a signet ring appearance. The histology of the tumours confirmed a well to moderately differentiated colorectal metastasis in 13 (86%) patients and hepatoma in two patients. R0 resection was achieved in 11 (76%) of patients. In two patients with R1 resection, the tumour was right on the right hepatic vein, and R0 would not have been possible. The resection margins were clear in two other patients but <1mm. The overall false positive rate in our experience with I-FIGS was 3%. In our limited experience, low-dose ICG administered at least 2–3 hours prior to surgery can accurately identify liver tumours and their margins in CSF mode. Superficially located lesions are easily identifiable under CSF mode, and CSF mode helped us identify the lesions and mark the resection margin. The use of ICG is an important advancement in liver surgery, and further research is needed to optimise image interpretation and correlate with clinical resection outcomes.
HPB P35荧光引导下的肝癌切除术:当天给药吲哚青绿与SPY-彩色分段荧光成像在术中识别肿瘤
吲哚菁绿(ICG)荧光成像是一种实时导航工具,在肝脏手术中显示出良好的效果。关于ICG给药的最佳时间和剂量,已经描述了几种方案。视觉上不同的荧光增强模式与不同的病理相关联,以帮助识别术中病变。本研究旨在介绍我们使用彩色分割荧光(CSF)模型和当日给药低剂量ICG在肝肿瘤切除术中的经验。我们介绍了一位外科医生(SA)在英国普利茅斯大学医院使用吲哚菁绿色荧光图像引导手术(I-FIGS)的经验。I-FIGS在2020年11月至2022年3月期间用于15名疑似肝肿瘤患者。ICG在肝手术前2-3小时以0.02 ~ 0.03 mg/kg的剂量静脉滴注。使用SPY CSF模式,图像被缩放到NIRF荧光强度,以识别肝肿瘤及其术中边缘。在研究期间,共有15例患者(8名男性)接受了I-FIGS检查,平均年龄为71岁(36-86岁)。其中67%接受了腹腔镜肝脏手术,78%接受了非解剖性切除,33%再次接受了肝脏手术。肿瘤平均大小40.6 mm,中位肿瘤数1个。所有病灶在脑脊液模式下均可见,且均呈印戒状。肿瘤组织学证实13例(86%)患者有中度分化的结直肠转移,2例患者有肝癌。11例(76%)患者实现R0切除。在两例R1切除的患者中,肿瘤正好在右肝静脉上,而R0是不可能的。另外2例患者切除边缘清晰,但<1mm。在我们的I-FIGS经验中,总体假阳性率为3%。根据我们有限的经验,在手术前至少2-3小时进行低剂量ICG可以准确识别脑脊液模式下的肝脏肿瘤及其边缘。在脑脊液模式下,浅表位置的病变容易被识别,脑脊液模式帮助我们识别病变并标记切除边缘。ICG的使用是肝脏手术的重要进步,需要进一步研究以优化图像解释并与临床切除结果相关联。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
12.70
自引率
7.30%
发文量
1102
审稿时长
1.5 months
期刊介绍: The British Journal of Surgery (BJS), incorporating the European Journal of Surgery, stands as Europe's leading peer-reviewed surgical journal. It serves as an invaluable platform for presenting high-quality clinical and laboratory-based research across a wide range of surgical topics. In addition to providing a comprehensive coverage of traditional surgical practices, BJS also showcases emerging areas in the field, such as minimally invasive therapy and interventional radiology. While the journal appeals to general surgeons, it also holds relevance for specialty surgeons and professionals working in closely related fields. By presenting cutting-edge research and advancements, BJS aims to revolutionize the way surgical knowledge is shared and contribute to the ongoing progress of the surgical community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书