Evaluation of Roundness Condition The Wall Structure Of Silos Wheat Storage Capacity 4650 Tons

S. Sukamta, S. A. Widyanto
{"title":"Evaluation of Roundness Condition The Wall Structure Of Silos Wheat Storage Capacity 4650 Tons","authors":"S. Sukamta, S. A. Widyanto","doi":"10.14710/mkts.v27i2.37097","DOIUrl":null,"url":null,"abstract":"This paper discusses the evaluation of asymmetrical inflating pattern phenomenon on the silo wall due to loading. The wall structure used corrugated wall modules with bolted connections. The storage capacity of the observed silo is 4,650 tons of wheat grains with a diameter of 19 m and a height of 20.875 m. Numerical analysis was performed using the finite element method. The condition of the bolt connection is directly measured using a torque wrench. Measurement and analysis is carried out when the silo is full or empty. The measurement results show that the bolt tightening torque in the full capacity loading of grain is about 2 times than that of when empty. This indicates that the silo walls are subjected shear stress of bolts on the overlap area between wall modules. The asymmetrical inflating pattern of the silo wall during loading is caused by the variation of the bolt tightness torque at the connection between the wall modules. The calculation results show that the minimum bolt tightness torque to produce friction stress (in the overlap area between wall modules) which is equal to the grain pressure stress is 47.36 Nm.","PeriodicalId":31880,"journal":{"name":"Media Komunikasi Teknik Sipil","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Media Komunikasi Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14710/mkts.v27i2.37097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper discusses the evaluation of asymmetrical inflating pattern phenomenon on the silo wall due to loading. The wall structure used corrugated wall modules with bolted connections. The storage capacity of the observed silo is 4,650 tons of wheat grains with a diameter of 19 m and a height of 20.875 m. Numerical analysis was performed using the finite element method. The condition of the bolt connection is directly measured using a torque wrench. Measurement and analysis is carried out when the silo is full or empty. The measurement results show that the bolt tightening torque in the full capacity loading of grain is about 2 times than that of when empty. This indicates that the silo walls are subjected shear stress of bolts on the overlap area between wall modules. The asymmetrical inflating pattern of the silo wall during loading is caused by the variation of the bolt tightness torque at the connection between the wall modules. The calculation results show that the minimum bolt tightness torque to produce friction stress (in the overlap area between wall modules) which is equal to the grain pressure stress is 47.36 Nm.
库容4650吨小麦的筒仓壁结构圆度评价
本文讨论了筒仓壁因载荷引起的不对称胀形现象的评价。墙体结构采用螺栓连接的波纹壁模块。观测到的筒仓容量为4650吨小麦,筒仓直径19 m,高度20.875 m。采用有限元法进行了数值分析。用力矩扳手直接测量螺栓连接状况。在筒仓满或空时进行测量和分析。测量结果表明,谷物满负荷加载时螺栓拧紧力矩约为空载时螺栓拧紧力矩的2倍。说明筒仓壁在筒仓模组重叠区域受到螺栓的剪应力作用。加载过程中筒仓壁的不对称胀形是由筒仓壁模块连接处螺栓紧力矩的变化引起的。计算结果表明,产生与晶粒压应力相等的摩擦应力(壁模间重叠区域)的最小螺栓紧力矩为47.36 Nm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书