{"title":"Detection of Selenium and Nickel Metal Ion in Water Using Mn3O4-Cn-Modified Electrode","authors":"N. John, K. E. Abraham","doi":"10.1155/2021/6650542","DOIUrl":null,"url":null,"abstract":"The present study reports the design of the Mn3O4-Cn electrode and its use for simultaneous detection of selenium and nickel in water. The designed electrode can be used as a convenient electrochemical device for on-site testing of Se (IV) and Ni (II) levels in affected regions. The best responses are obtained with 0.1 M phosphate buffer saline (PBS) and 5 mM Fe (CN)6 as supporting electrolyte. The scan rate and the number of cyclic repetitions have a great effect on peak shape and intensity. It is seen from our study that peak intensity is directly proportional to Se (IV) and Ni (II) concentrations in the range of 5 to 250 µg/L (correlation coefficients 0.952 and 0.984) when the optimized parameters are used. The detection limit of 0.533 µg/L Se (IV) and 0.718 µg/L for Ni (VI) with a response time of 18 s for 5–250 µg/L concentration is obtained, respectively. Enhanced analytical results for different water samples establish that the proposed method is appropriate for Se (IV) and Ni (II) detection. FESEM images confirm the Mn3O4-Cn nanocomposite formation on the electrode.","PeriodicalId":13933,"journal":{"name":"International journal of electrochemistry","volume":"2021 1","pages":"1-9"},"PeriodicalIF":2.3000,"publicationDate":"2021-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of electrochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2021/6650542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 2
Abstract
The present study reports the design of the Mn3O4-Cn electrode and its use for simultaneous detection of selenium and nickel in water. The designed electrode can be used as a convenient electrochemical device for on-site testing of Se (IV) and Ni (II) levels in affected regions. The best responses are obtained with 0.1 M phosphate buffer saline (PBS) and 5 mM Fe (CN)6 as supporting electrolyte. The scan rate and the number of cyclic repetitions have a great effect on peak shape and intensity. It is seen from our study that peak intensity is directly proportional to Se (IV) and Ni (II) concentrations in the range of 5 to 250 µg/L (correlation coefficients 0.952 and 0.984) when the optimized parameters are used. The detection limit of 0.533 µg/L Se (IV) and 0.718 µg/L for Ni (VI) with a response time of 18 s for 5–250 µg/L concentration is obtained, respectively. Enhanced analytical results for different water samples establish that the proposed method is appropriate for Se (IV) and Ni (II) detection. FESEM images confirm the Mn3O4-Cn nanocomposite formation on the electrode.