{"title":"Detection and quantification of bolt loosening using RGB-D camera and Mask R-CNN","authors":"Junyeon Chung, H. Sohn","doi":"10.12989/SSS.2021.27.5.783","DOIUrl":null,"url":null,"abstract":"Bolt loosening is one of the most common types of damage for bolt-connected plates. Existing vision techniques detect bolt loosening based on the measurement of bolt rotation or the exposure of bolt threads. However, these techniques examine bolt tightness only in a qualitative manner, or require a reference measurement at the initially tightened state of the bolt for quantitative estimation. In this study, the exposed shank length of a bolt is quantitatively measured using an RGB-depth camera and a mask-region-based convolutional neural network but without requiring any measurement from the initial state of the bolt. The performance of the proposed technique is validated by conducting lab-scale experiments, in which the angle and distance of the camera are varied with respect to a target inspection area. The proposed technique successfully detects bolt loosening at exposed shank length over 3 mm with a resolution of 1 mm and 97% accuracy at different camera angles (40°–90°) and distances (up to 65 cm).","PeriodicalId":51155,"journal":{"name":"Smart Structures and Systems","volume":"27 1","pages":"783"},"PeriodicalIF":2.1000,"publicationDate":"2021-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Smart Structures and Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.12989/SSS.2021.27.5.783","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 2
Abstract
Bolt loosening is one of the most common types of damage for bolt-connected plates. Existing vision techniques detect bolt loosening based on the measurement of bolt rotation or the exposure of bolt threads. However, these techniques examine bolt tightness only in a qualitative manner, or require a reference measurement at the initially tightened state of the bolt for quantitative estimation. In this study, the exposed shank length of a bolt is quantitatively measured using an RGB-depth camera and a mask-region-based convolutional neural network but without requiring any measurement from the initial state of the bolt. The performance of the proposed technique is validated by conducting lab-scale experiments, in which the angle and distance of the camera are varied with respect to a target inspection area. The proposed technique successfully detects bolt loosening at exposed shank length over 3 mm with a resolution of 1 mm and 97% accuracy at different camera angles (40°–90°) and distances (up to 65 cm).
期刊介绍:
An International Journal of Mechatronics, Sensors, Monitoring, Control, Diagnosis, and Management airns at providing a major publication channel for researchers in the general area of smart structures and systems. Typical subjects considered by the journal include:
Sensors/Actuators(Materials/devices/ informatics/networking)
Structural Health Monitoring and Control
Diagnosis/Prognosis
Life Cycle Engineering(planning/design/ maintenance/renewal)
and related areas.