A Novel Technique to Perform Microvascular Anastomosis Revisions without Clamps

Amro A Harb, Maxwell Levi, Y. Akelina, R. K. Kadiyala, J. Ascherman
{"title":"A Novel Technique to Perform Microvascular Anastomosis Revisions without Clamps","authors":"Amro A Harb, Maxwell Levi, Y. Akelina, R. K. Kadiyala, J. Ascherman","doi":"10.1055/s-0038-1669451","DOIUrl":null,"url":null,"abstract":"Abstract Background For surgeons learning microsurgery, uneven spacing between sutures while performing microvascular arterial anastomoses is one of the most common technical errors made that can lead to leakage. Based on the previous surgical experience and training of these surgeons, the first option chosen to prevent bleeding is to place a vascular clamp proximal to the anastomosis and an additional suture at the site of the leak. Because this technique may have technical and thrombosis concerns, our study proposes an alternative technique of performing post-anastomotic revisions without the use of clamps. Methods Our technique involves placing a cotton-tipped applicator under the artery and lifting it to partially occlude flow within the vessel as an additional suture is placed at the leakage site to complete the revision. One-hundred eighty-four microvascular anastomoses were performed on the femoral arteries of 92 Sprague-Dawley rats, and of the 184 anastomoses, 147 had a leak and required a post-anastomotic revision. All revisions were completed using our technique, and no clamps were used during any of the revisions. Results Of the 147 post-anastomotic revisions completed using our technique, 141 (95.9%) were patent 2 hours post-revision. The mean operating time for the revisions was 5:03 minutes (range, 1:44–6:30 minutes). Conclusion Our technique of partially occluding an artery with a cotton-tipped applicator while performing a post-anastomotic revision is a safe and effective alternative to using vascular clamps. Our technique may also reduce technical errors and have a low risk of causing thrombosis when completing post-anastomotic revisions.","PeriodicalId":34024,"journal":{"name":"Journal of Reconstructive Microsurgery Open","volume":"3 1","pages":"e58 - e61"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/s-0038-1669451","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Reconstructive Microsurgery Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0038-1669451","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Abstract Background For surgeons learning microsurgery, uneven spacing between sutures while performing microvascular arterial anastomoses is one of the most common technical errors made that can lead to leakage. Based on the previous surgical experience and training of these surgeons, the first option chosen to prevent bleeding is to place a vascular clamp proximal to the anastomosis and an additional suture at the site of the leak. Because this technique may have technical and thrombosis concerns, our study proposes an alternative technique of performing post-anastomotic revisions without the use of clamps. Methods Our technique involves placing a cotton-tipped applicator under the artery and lifting it to partially occlude flow within the vessel as an additional suture is placed at the leakage site to complete the revision. One-hundred eighty-four microvascular anastomoses were performed on the femoral arteries of 92 Sprague-Dawley rats, and of the 184 anastomoses, 147 had a leak and required a post-anastomotic revision. All revisions were completed using our technique, and no clamps were used during any of the revisions. Results Of the 147 post-anastomotic revisions completed using our technique, 141 (95.9%) were patent 2 hours post-revision. The mean operating time for the revisions was 5:03 minutes (range, 1:44–6:30 minutes). Conclusion Our technique of partially occluding an artery with a cotton-tipped applicator while performing a post-anastomotic revision is a safe and effective alternative to using vascular clamps. Our technique may also reduce technical errors and have a low risk of causing thrombosis when completing post-anastomotic revisions.
一种无需夹钳进行微血管吻合修复的新技术
摘要背景 对于学习显微外科的外科医生来说,在进行微血管-动脉吻合时,缝线之间的不均匀间距是最常见的技术错误之一,可能导致渗漏。根据这些外科医生以前的手术经验和培训,预防出血的第一个选择是在吻合口附近放置血管夹,并在渗漏部位额外缝合。由于这项技术可能涉及技术和血栓形成问题,我们的研究提出了一种不使用夹子进行吻合后翻修的替代技术。方法 我们的技术包括在动脉下放置一个棉头敷贴器,并将其提起,以部分阻断血管内的流动,同时在渗漏部位放置一条额外的缝合线以完成翻修。对92只Sprague-Dawley大鼠的股动脉进行了184次微血管吻合,在184次吻合中,147次发生渗漏,需要进行吻合后翻修。所有修订都是使用我们的技术完成的,在任何修订过程中都没有使用夹具。后果 在使用我们的技术完成的147例吻合后翻修中,141例(95.9%)在翻修后2小时内获得专利。修订的平均操作时间为5:03分钟(范围为1:44-6:30分钟)。结论 我们的技术是在进行吻合口后翻修时使用棉头涂抹器部分闭塞动脉,这是使用血管夹的一种安全有效的替代方法。我们的技术还可以减少技术错误,并且在完成吻合口后翻修时导致血栓形成的风险很低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
6
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信