{"title":"Construction of New Coated Carbon Electrodes for Determination of Sildenafil Citrate Drug","authors":"Aveen K. Mohammed, A. Khaleel, Nawzad N. Ahmed","doi":"10.32894/kujss.2020.15.2.1","DOIUrl":null,"url":null,"abstract":"In this research, new coated carbon electrodes were constructed and used for the determination of Sildenafil citrate (SILC) drug. The electrodes were constructed by preparing ion-pair for (SILC) with phosphotungstic acid (PTA) or phosphomolybdic (PMA) acid using dibutyl phthalate (DBP) as a plasticizer. These electrodes showed good sensitivity towards SILC with linear range of (1.010 -7 -1.010 -2 ) M, correlation coefficient, (0.9990), the life time (120) days, optimum temperature range (23-65) o C and optimum pH range (2-5) for both electrodes, limit of detection (5.05510 -8 and 5.11610 -8 ) M, slope (57.29 and 59.10) mV/decadefor SILC-PTA and SILC-PMA electrodes respectively. These electrodes were successfully applied for determination of SILC in pure and pharmaceutical preparation form(tablets) with recovery of not less than 98%.","PeriodicalId":34247,"journal":{"name":"mjl@ jm`@ krkwk ldrst l`lmy@","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"mjl@ jm`@ krkwk ldrst l`lmy@","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32894/kujss.2020.15.2.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
In this research, new coated carbon electrodes were constructed and used for the determination of Sildenafil citrate (SILC) drug. The electrodes were constructed by preparing ion-pair for (SILC) with phosphotungstic acid (PTA) or phosphomolybdic (PMA) acid using dibutyl phthalate (DBP) as a plasticizer. These electrodes showed good sensitivity towards SILC with linear range of (1.010 -7 -1.010 -2 ) M, correlation coefficient, (0.9990), the life time (120) days, optimum temperature range (23-65) o C and optimum pH range (2-5) for both electrodes, limit of detection (5.05510 -8 and 5.11610 -8 ) M, slope (57.29 and 59.10) mV/decadefor SILC-PTA and SILC-PMA electrodes respectively. These electrodes were successfully applied for determination of SILC in pure and pharmaceutical preparation form(tablets) with recovery of not less than 98%.