Strengthening of reinforced concrete structures by composite materials taking into consideration the carbonization of concrete

V. Rimshin, P. Truntov
{"title":"Strengthening of reinforced concrete structures by composite materials taking into consideration the carbonization of concrete","authors":"V. Rimshin, P. Truntov","doi":"10.22363/1815-5235-2023-19-2-178-185","DOIUrl":null,"url":null,"abstract":"One of the main causes for deterioration of reinforced concrete structures in modern construction is corrosion of reinforcement. Corrosion leads to decrease of adhesion between reinforcement and concrete, formation of cracks and destruction of the protective layer of concrete. All this reduces the load-bearing capacity of reinforced concrete structures. The structures of sludge reservoirs exposed to carbon dioxide were used as an object of the study. The characteristic defects and damages revealed by visual inspection were described. The verification calculation of the considered construction depending on the pH of the medium was performed on the basis of the results of technical inspection and study. The degree of carbon dioxide impact on the considered structures was determined by the phenolphthalein test method, which is based on the color change of acid-base indicator solution on the surface of concrete and reinforced concrete depending on the pH value of its medium. The phenolphthalein test revealed that pH of the medium is less than 8 for the depth more than the thickness of the concrete protective layer. A verification calculation of the considered structure was performed on the basis of the technical inspection results and the conducted research. According to the calculation results, a variant of beam reconstruction and strengthening using external reinforcement based on carbon fibers FibARM 230/150 was proposed. The reconstruction was carried out with account of the carbonized concrete layer.","PeriodicalId":32610,"journal":{"name":"Structural Mechanics of Engineering Constructions and Buildings","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Mechanics of Engineering Constructions and Buildings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22363/1815-5235-2023-19-2-178-185","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

One of the main causes for deterioration of reinforced concrete structures in modern construction is corrosion of reinforcement. Corrosion leads to decrease of adhesion between reinforcement and concrete, formation of cracks and destruction of the protective layer of concrete. All this reduces the load-bearing capacity of reinforced concrete structures. The structures of sludge reservoirs exposed to carbon dioxide were used as an object of the study. The characteristic defects and damages revealed by visual inspection were described. The verification calculation of the considered construction depending on the pH of the medium was performed on the basis of the results of technical inspection and study. The degree of carbon dioxide impact on the considered structures was determined by the phenolphthalein test method, which is based on the color change of acid-base indicator solution on the surface of concrete and reinforced concrete depending on the pH value of its medium. The phenolphthalein test revealed that pH of the medium is less than 8 for the depth more than the thickness of the concrete protective layer. A verification calculation of the considered structure was performed on the basis of the technical inspection results and the conducted research. According to the calculation results, a variant of beam reconstruction and strengthening using external reinforcement based on carbon fibers FibARM 230/150 was proposed. The reconstruction was carried out with account of the carbonized concrete layer.
考虑混凝土碳化的复合材料加固钢筋混凝土结构
钢筋锈蚀是现代建筑中钢筋混凝土结构劣化的主要原因之一。腐蚀导致钢筋与混凝土之间的附着力降低,形成裂缝,破坏混凝土的保护层。所有这些都降低了钢筋混凝土结构的承载能力。以暴露于二氧化碳的污泥库结构为研究对象。介绍了外观检查发现的特征性缺陷和损伤。根据技术检查和研究的结果,根据介质的pH值对所考虑的结构进行了验证计算。二氧化碳对所考虑结构的影响程度通过酚酞试验方法确定,该方法基于混凝土和钢筋混凝土表面酸碱指示剂溶液的颜色变化,取决于其介质的pH值。酚酞试验表明,介质的pH值小于8,深度大于混凝土保护层的厚度。根据技术检查结果和所进行的研究,对所考虑的结构进行了验证计算。根据计算结果,提出了一种基于碳纤维FibARM230/150的梁体外加固改造方案。重建是在考虑碳化混凝土层的情况下进行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
26
审稿时长
18 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信