K. Sim, B. Park, Byunjun Kim, Y. Han, N. Y. Han, Min Ju Kim, D. Sung, Sang-Hyun Park, Kwang-Sig Lee, Yongwon Cho
{"title":"Body Navigation-loaded Ultrasound Acquisition Technology: a Pilot Comparison With Conventional Ultrasound","authors":"K. Sim, B. Park, Byunjun Kim, Y. Han, N. Y. Han, Min Ju Kim, D. Sung, Sang-Hyun Park, Kwang-Sig Lee, Yongwon Cho","doi":"10.21203/rs.3.rs-781540/v1","DOIUrl":null,"url":null,"abstract":"\n Background: To investigate the usefulness of body navigation-loaded ultrasound including a real time transducer location and the inspection site compared with conventional ultrasound images.Methods: Under the approval of institutional review board, we prospectively enrolled total 29 healthy adult volunteers. One gastrointestinal radiologist performed abdominal ultrasound simultaneously using Ultrasound Navigation Image Convergence System developed by researchers. Subsequently, an equivalent conventional ultrasound image set was prepared. Three radiologists independently evaluated the two ultrasound image sets regarding the recognition of the target organ (2-points), the transducer location (2-points), and the transducer orientation (1-point). At intervals of two-weeks, conventional ultrasound images were analyzed first, and body navigation-loaded images were later analyzed. The score differences between the first and second evaluations were compared using the Wilcoxon signed rank test. Inter-rater agreement of three reviewers was obtained by the Fleiss’ Kappa test.Results: A total of 1402 navigation-loaded ultrasound images were obtained. Ultrasound operator carefully selected a total of 203 images for analysis. In all three reviewers, the interpretation score of each evaluation was significantly increased in the second analysis using the body navigation-loaded ultrasound image (in reviewer A, from 4.07±1.56 to 4.79±0.69 points; in reviewer B, from 3.83±1.59 to 4.49±0.88 points; in reviewer C, from 3.43±1.60 to 4.19±1.01 points; P<.0001). The inter-rater agreement of each evaluation also increased significantly in the second analysis using the body navigation-loaded ultrasound image (P<.0001).Conclusion: The body navigation-loaded ultrasound imaging system allows other medical staffs to easily and accurately interpret ultrasound images.","PeriodicalId":50273,"journal":{"name":"Iranian Journal of Radiology","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2021-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21203/rs.3.rs-781540/v1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background: To investigate the usefulness of body navigation-loaded ultrasound including a real time transducer location and the inspection site compared with conventional ultrasound images.Methods: Under the approval of institutional review board, we prospectively enrolled total 29 healthy adult volunteers. One gastrointestinal radiologist performed abdominal ultrasound simultaneously using Ultrasound Navigation Image Convergence System developed by researchers. Subsequently, an equivalent conventional ultrasound image set was prepared. Three radiologists independently evaluated the two ultrasound image sets regarding the recognition of the target organ (2-points), the transducer location (2-points), and the transducer orientation (1-point). At intervals of two-weeks, conventional ultrasound images were analyzed first, and body navigation-loaded images were later analyzed. The score differences between the first and second evaluations were compared using the Wilcoxon signed rank test. Inter-rater agreement of three reviewers was obtained by the Fleiss’ Kappa test.Results: A total of 1402 navigation-loaded ultrasound images were obtained. Ultrasound operator carefully selected a total of 203 images for analysis. In all three reviewers, the interpretation score of each evaluation was significantly increased in the second analysis using the body navigation-loaded ultrasound image (in reviewer A, from 4.07±1.56 to 4.79±0.69 points; in reviewer B, from 3.83±1.59 to 4.49±0.88 points; in reviewer C, from 3.43±1.60 to 4.19±1.01 points; P<.0001). The inter-rater agreement of each evaluation also increased significantly in the second analysis using the body navigation-loaded ultrasound image (P<.0001).Conclusion: The body navigation-loaded ultrasound imaging system allows other medical staffs to easily and accurately interpret ultrasound images.
期刊介绍:
The Iranian Journal of Radiology is the official journal of Tehran University of Medical Sciences and the Iranian Society of Radiology. It is a scientific forum dedicated primarily to the topics relevant to radiology and allied sciences of the developing countries, which have been neglected or have received little attention in the Western medical literature.
This journal particularly welcomes manuscripts which deal with radiology and imaging from geographic regions wherein problems regarding economic, social, ethnic and cultural parameters affecting prevalence and course of the illness are taken into consideration.
The Iranian Journal of Radiology has been launched in order to interchange information in the field of radiology and other related scientific spheres. In accordance with the objective of developing the scientific ability of the radiological population and other related scientific fields, this journal publishes research articles, evidence-based review articles, and case reports focused on regional tropics.
Iranian Journal of Radiology operates in agreement with the below principles in compliance with continuous quality improvement:
1-Increasing the satisfaction of the readers, authors, staff, and co-workers.
2-Improving the scientific content and appearance of the journal.
3-Advancing the scientific validity of the journal both nationally and internationally.
Such basics are accomplished only by aggregative effort and reciprocity of the radiological population and related sciences, authorities, and staff of the journal.