Comparison of Transcorneal and Transpalpebral Ultrasonographic Measurements of the Eye in Iranian Mix Breed Dog

Q4 Veterinary
R. Vali, M. Razeghi
{"title":"Comparison of Transcorneal and Transpalpebral Ultrasonographic Measurements of the Eye in Iranian Mix Breed Dog","authors":"R. Vali, M. Razeghi","doi":"10.22034/IVSA.2019.154146.1165","DOIUrl":null,"url":null,"abstract":"Objective-The aim of this research was to compare transcorneal and transpalpebral ultrasonography study of the dimensions (ecobiometry) and the ultrasonographic aspect of Iranian mix breed dogs.Design- Experimental studyAnimals- . Ten adult male dogsProcedure- Ten adult male dogs with the mean age 4±1.39 years and the mean weight of 16.7±3.6 kg were selected and distributed in two equal groups. Transcorneal and transpalpebral ultrasonographic scanning of left and right eyes of dogs were performed using with a 12 MHZ transducer. The transducer was placed in a longitudinal position (sagittal plane) until optimal B-scan images, were obtained.Results- Means and standard deviations of the intraocular structures of both transcorneal and transpalpebral were as, Anterior chamber depth (2.99±0.242, 2.78±0.285 mm), Lens thickness (6.62±0.364,7.02±0.612 mm), Vitreous chamber depth (8.81±0.354, 8.79±0.552 mm) and Axial globe length (19.60±0.452,19.50±0.592 mm) respectively. No significant differences were observed when comparing left and right eyes of dogs in both methods within the same group and comparing between two groups (p>0.05).Conclusion and Clinical Relevance- Results of this study can be used as a template in diagnosis of ocular disease and facilitates the use of transpalpebral ultrasonography in the evaluation of ocular structures in ocular disease specially painful conditions.","PeriodicalId":14554,"journal":{"name":"Iranian Journal of Veterinary Surgery","volume":"14 1","pages":"91-96"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Veterinary Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22034/IVSA.2019.154146.1165","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Veterinary","Score":null,"Total":0}
引用次数: 0

Abstract

Objective-The aim of this research was to compare transcorneal and transpalpebral ultrasonography study of the dimensions (ecobiometry) and the ultrasonographic aspect of Iranian mix breed dogs.Design- Experimental studyAnimals- . Ten adult male dogsProcedure- Ten adult male dogs with the mean age 4±1.39 years and the mean weight of 16.7±3.6 kg were selected and distributed in two equal groups. Transcorneal and transpalpebral ultrasonographic scanning of left and right eyes of dogs were performed using with a 12 MHZ transducer. The transducer was placed in a longitudinal position (sagittal plane) until optimal B-scan images, were obtained.Results- Means and standard deviations of the intraocular structures of both transcorneal and transpalpebral were as, Anterior chamber depth (2.99±0.242, 2.78±0.285 mm), Lens thickness (6.62±0.364,7.02±0.612 mm), Vitreous chamber depth (8.81±0.354, 8.79±0.552 mm) and Axial globe length (19.60±0.452,19.50±0.592 mm) respectively. No significant differences were observed when comparing left and right eyes of dogs in both methods within the same group and comparing between two groups (p>0.05).Conclusion and Clinical Relevance- Results of this study can be used as a template in diagnosis of ocular disease and facilitates the use of transpalpebral ultrasonography in the evaluation of ocular structures in ocular disease specially painful conditions.
伊朗混血犬经角膜和经眼睑超声检查的比较
目的:比较伊朗混交种犬经角膜和经睑超声对其外形(生物计量学)和超声方面的研究。设计-实验研究-动物-。方法:选取平均年龄(4±1.39)岁、平均体重(16.7±3.6)kg的成年雄性犬10只,随机分为两组。采用12 MHZ换能器对犬左右眼进行经角膜和经眼睑超声扫描。换能器放置在纵向位置(矢状面),直到获得最佳的b扫描图像。结果:经角膜和经眼睑的眼内结构的均值和标准差分别为:前房深度(2.99±0.242,2.78±0.285 mm)、晶状体厚度(6.62±0.364,7.02±0.612 mm)、玻璃体深度(8.81±0.354,8.79±0.552 mm)和眼轴长度(19.60±0.452,19.50±0.592 mm)。两种方法在同一组内、两组间左、右眼比较,差异均无统计学意义(p < 0.05)。结论及临床意义-本研究结果可作为眼部疾病诊断的模板,促进经睑超声在眼部疾病特别是疼痛情况下对眼部结构的评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
审稿时长
30 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信