{"title":"Transcatheter closure of Patent ductus arteriosus at Shahid Gangalal National Heart Centre, Kathmandu, Nepal","authors":"C. Adhikari, R. Malla, U. Shakya, M. Shrestha, B. Rauniyar, Deepak Limbu, Poonam Sharma, M. Gautam, Shilpa Aryal, Achhita Kc","doi":"10.3126/JAIM.V6I1.18310","DOIUrl":null,"url":null,"abstract":"Background and Aims: In the current era, transcatheter closure of patent ductus arteriosus (PDA) using either coils or device is a well-established procedure. The aim of this study was to assess safety of transcatheter closure of PDA at Shahid Gangalal national heart Centre, Kathmandu, Nepal.Methods: It was a single centre, retrospective study conducted between March 2007 to March 2017. Cardiac catheterization laboratory records of all consecutive patients who underwent PDA device closure were included. A lateral view Aortic angiogram was performed to determine the morphology and size of the duct. Device type and size was selected as per the aortogram. A second aortic angiogram was performed 5 min after device deployment to determine the success of the closure. Echocardiography was done next day of the procedure to assess success of the closure.Result: During the study period 126 patients were attempted for transcatheter closure of PDA. Six patient were thought to have unfavorable size or shape, and transcatheter occlusion was not attempted. In one patients attempt was made to close the duct with cook coil which embolized to pulmonary artery. One hundred and nineteen patient PDA was successfully closed. Among the 119 patients 89 were female and 30 were male. The PDA was closed by Amplatzer duct occluder in 99 patients, Life tech PDA occluder in 14 patients, Hyperion PDA occluder in two patients, Post-infarct Muscular VSD Occluder in four patients.Conclusions: Transcatheter closure of PDA can be done safely with high success rate.","PeriodicalId":75443,"journal":{"name":"Advances in internal medicine","volume":"6 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3126/JAIM.V6I1.18310","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in internal medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/JAIM.V6I1.18310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Background and Aims: In the current era, transcatheter closure of patent ductus arteriosus (PDA) using either coils or device is a well-established procedure. The aim of this study was to assess safety of transcatheter closure of PDA at Shahid Gangalal national heart Centre, Kathmandu, Nepal.Methods: It was a single centre, retrospective study conducted between March 2007 to March 2017. Cardiac catheterization laboratory records of all consecutive patients who underwent PDA device closure were included. A lateral view Aortic angiogram was performed to determine the morphology and size of the duct. Device type and size was selected as per the aortogram. A second aortic angiogram was performed 5 min after device deployment to determine the success of the closure. Echocardiography was done next day of the procedure to assess success of the closure.Result: During the study period 126 patients were attempted for transcatheter closure of PDA. Six patient were thought to have unfavorable size or shape, and transcatheter occlusion was not attempted. In one patients attempt was made to close the duct with cook coil which embolized to pulmonary artery. One hundred and nineteen patient PDA was successfully closed. Among the 119 patients 89 were female and 30 were male. The PDA was closed by Amplatzer duct occluder in 99 patients, Life tech PDA occluder in 14 patients, Hyperion PDA occluder in two patients, Post-infarct Muscular VSD Occluder in four patients.Conclusions: Transcatheter closure of PDA can be done safely with high success rate.
尼泊尔加德满都Shahid Gangalal国家心脏中心动脉导管未闭的经导管闭合术
背景和目的:在当今时代,使用线圈或装置经导管封堵动脉导管未闭(PDA)是一种公认的方法。本研究旨在评估尼泊尔加德满都Shahid Gangalal国家心脏中心经导管封堵PDA的安全性。方法:这是一项在2007年3月至2017年3月期间进行的单中心回顾性研究。包括所有连续接受PDA封堵器的患者的心导管插入术实验室记录。进行侧视图主动脉造影以确定导管的形态和大小。根据主动脉图选择器械类型和尺寸。在装置部署后5分钟进行第二次主动脉造影,以确定闭合的成功。术后第二天进行超声心动图检查,以评估闭合的成功率。结果:在研究期间,126名患者尝试经导管封堵PDA。6名患者被认为大小或形状不合适,未尝试经导管封堵。在一名患者中,尝试用栓塞在肺动脉上的线圈封闭导管。119名患者PDA成功闭合。119例患者中女性89例,男性30例。99例患者使用Amplatzer导管封堵器闭合PDA,14例患者使用Life tech PDA封堵器,2例患者使用Hyperion PDA封堵剂,4例患者使用梗死后肌肉室间隔缺损封堵器。结论:PDA经导管封堵术安全、成功率高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书