{"title":"Acoustics in South African classrooms: Regulations versus reality","authors":"Coralie van Reenen, C. Plessis","doi":"10.1177/1351010X211036904","DOIUrl":null,"url":null,"abstract":"This research set out to broaden the pool of evidence regarding the acoustic conditions at schools in South Africa. A review of local and international literature, standards and design guidelines shows that the ideal classroom acoustic conditions of 35 dBA ambient and 0.7 s reverberation time are required to enable a suitable environment for teaching and learning. A review of local literature revealed a very small body of knowledge regarding actual acoustic conditions and monitoring of classroom acoustics and that these cases demonstrated ambient noise levels in classrooms (whether occupied or unoccupied) to be above the recommendations of the relevant South African National Standard (SANS 10103). The limited local research promted the need for this case study. The findings of a province-wide survey of urban schools showed that traffic noise is the main source of noise disturbance in schools. A case study of five schools showed that the average outdoor noise level at schools exposed to traffic throughout the day is 63.3 dBA and the average indoor noise level at these schools when classrooms are unoccupied is approximately 58 dBA, which is significantly higher than the requirement. The reverberation time in classrooms was between 0.6 and 1.75 s. It is concluded that the current acoustic conditions in South African urban schools is poor when evaluated against the South African National Standards. However, since this is based on only five case studies, a broader study is required to understand the general conditions and establish suitable mitigation measures.","PeriodicalId":51841,"journal":{"name":"BUILDING ACOUSTICS","volume":"29 1","pages":"157 - 178"},"PeriodicalIF":1.9000,"publicationDate":"2021-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BUILDING ACOUSTICS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1351010X211036904","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 2

Abstract

This research set out to broaden the pool of evidence regarding the acoustic conditions at schools in South Africa. A review of local and international literature, standards and design guidelines shows that the ideal classroom acoustic conditions of 35 dBA ambient and 0.7 s reverberation time are required to enable a suitable environment for teaching and learning. A review of local literature revealed a very small body of knowledge regarding actual acoustic conditions and monitoring of classroom acoustics and that these cases demonstrated ambient noise levels in classrooms (whether occupied or unoccupied) to be above the recommendations of the relevant South African National Standard (SANS 10103). The limited local research promted the need for this case study. The findings of a province-wide survey of urban schools showed that traffic noise is the main source of noise disturbance in schools. A case study of five schools showed that the average outdoor noise level at schools exposed to traffic throughout the day is 63.3 dBA and the average indoor noise level at these schools when classrooms are unoccupied is approximately 58 dBA, which is significantly higher than the requirement. The reverberation time in classrooms was between 0.6 and 1.75 s. It is concluded that the current acoustic conditions in South African urban schools is poor when evaluated against the South African National Standards. However, since this is based on only five case studies, a broader study is required to understand the general conditions and establish suitable mitigation measures.
南非课堂声学:法规与现实
这项研究旨在扩大南非学校声学条件的证据库。对当地和国际文献、标准和设计指南的审查表明,35 dBA环境和0.7 s的混响时间,以便为教学和学习提供合适的环境。对当地文献的审查显示,关于实际声学条件和教室声学监测的知识非常少,这些案例表明,教室(无论是有人还是无人)的环境噪声水平高于相关南非国家标准(SANS 10103)的建议。当地有限的研究促使人们有必要进行这一案例研究。全省城市学校调查结果表明,交通噪声是学校噪声干扰的主要来源。一项针对五所学校的案例研究表明,全天暴露在交通中的学校的平均室外噪音水平为63.3 dBA,当教室空置时,这些学校的平均室内噪音水平约为58 dBA,明显高于要求。教室里的混响时间在0.6到1.75之间 s.根据南非国家标准进行评估,得出的结论是,南非城市学校目前的声学条件较差。然而,由于这仅基于五个案例研究,因此需要进行更广泛的研究,以了解一般情况并制定适当的缓解措施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BUILDING ACOUSTICS
BUILDING ACOUSTICS ACOUSTICS-
CiteScore
4.10
自引率
11.80%
发文量
22
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信