Investigation of the effectiveness of ECOLAB ’Drape ArmourTM’ Radiation Protection in limiting eye-lens doses of healthcare personnel exposed to ionizing radiation during gastroenterology - interventional radiology procedures
Fucilli Fulvio IM, Giovanni Giuseppe Di, Mastrorocco Alessandro, Ninni Matteo, Loprete Piero, Crudis Isa De, Marano Massimiliano, Santomauro Antonio, Fucilli Fabio
{"title":"Investigation of the effectiveness of ECOLAB ’Drape ArmourTM’ Radiation Protection in limiting eye-lens doses of healthcare personnel exposed to ionizing radiation during gastroenterology - interventional radiology procedures","authors":"Fucilli Fulvio IM, Giovanni Giuseppe Di, Mastrorocco Alessandro, Ninni Matteo, Loprete Piero, Crudis Isa De, Marano Massimiliano, Santomauro Antonio, Fucilli Fabio","doi":"10.17352/2581-5407.000048","DOIUrl":null,"url":null,"abstract":"Objectives: To investigate the efficiency of the ECOLAB “Drape ArmourTM” device in limiting the eye-lens doses absorbed by healthcare personnel exposed to ionizing radiation, in a four-month trial during gastroenterology interventional radiology procedures. Methods: Eyelens doses measured with eye-lens dosimeters calibrated in terms of equivalent dose at 3 mm depth ( Hp(3) ) were collected and analyzed since 2016 along with the irradiation parameters (Dose Area Product - DAP). The eye-lens doses received during the four-month trial, have been compared with doses normally received, in the same conditions of irradiation, in the absence of the protection drape. Results: During the period of use of Drape ArmourTM, the average dose to the eye lens was estimated to be 0.73 mSv (St.dev = 0.40 mSv). The average dose to the eye lens, measured in the same four-month period, across different years from 2017 to 2021, was equal to 1.30 mSv (st. dev = 0.35 mSv). Conclusions: Results suggest the effectiveness of Drape ArmourTM in containing the doses to the eye lens. Keypoint: Limiting eye-lens doses to a maximum value of 20 mSv/year is a real challenge, especially in interventional radiologic facilities. The use of suitable radio-opaque drapes may help healthcare workers involved in such facilities. The aim of the work is to evaluate the efficiency of the ECOLAB “Drape ArmourTM” sterile mono-use drape.","PeriodicalId":73166,"journal":{"name":"Global journal of cancer therapy","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global journal of cancer therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17352/2581-5407.000048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: To investigate the efficiency of the ECOLAB “Drape ArmourTM” device in limiting the eye-lens doses absorbed by healthcare personnel exposed to ionizing radiation, in a four-month trial during gastroenterology interventional radiology procedures. Methods: Eyelens doses measured with eye-lens dosimeters calibrated in terms of equivalent dose at 3 mm depth ( Hp(3) ) were collected and analyzed since 2016 along with the irradiation parameters (Dose Area Product - DAP). The eye-lens doses received during the four-month trial, have been compared with doses normally received, in the same conditions of irradiation, in the absence of the protection drape. Results: During the period of use of Drape ArmourTM, the average dose to the eye lens was estimated to be 0.73 mSv (St.dev = 0.40 mSv). The average dose to the eye lens, measured in the same four-month period, across different years from 2017 to 2021, was equal to 1.30 mSv (st. dev = 0.35 mSv). Conclusions: Results suggest the effectiveness of Drape ArmourTM in containing the doses to the eye lens. Keypoint: Limiting eye-lens doses to a maximum value of 20 mSv/year is a real challenge, especially in interventional radiologic facilities. The use of suitable radio-opaque drapes may help healthcare workers involved in such facilities. The aim of the work is to evaluate the efficiency of the ECOLAB “Drape ArmourTM” sterile mono-use drape.