Perspectives on the use of electrostimulation with the device “VEB”® in the management of disorders related to COVID-19

IF 0.2
W. Zukow
{"title":"Perspectives on the use of electrostimulation with the device “VEB”® in the management of disorders related to COVID-19","authors":"W. Zukow","doi":"10.31219/osf.io/cd4mv","DOIUrl":null,"url":null,"abstract":"Background. One of the symptoms of COVID-19 is the so-called \"cytokine storm\". Its pathogenesis is that the initial release by lymphocytes and macrophages of proinflammatory cytokines in the classical immune response to SARS-CoV-2 is significantly enhanced and maintained due to excessive adrenergic stimulation of the immune cells. The proinflammatory adrenergic mechanism of the \"cytokine storm\" can be offset by the activation of the anti-inflammatory cholinergic mechanism by non-invasive stimulation of the vagus nerve. In 2015, a generator for electrotherapy and stimulation oh human nerve centers was created, called “VEB-1”®. Preliminary observation of volunteers revealed a modulating effect of a four-day course of electrical stimulation on the parameters of electroencephalogram, metabolism, as well as gas-discharge visualization (GDV). We hypothesized that changes in EEG parameters may be accompanied by a vagotonic shift of the sympatho-vagus balance, favorable for calming the “cytokine storm”. The main purpose of this study was to find out. In addition, concomitant changes in EEG, immunity, GDV, etc. due to the use of the devices \"VEB-1\"® and recently designed \"VEB-2\" had to be detected. Material and research methods. The object of observation were 18 volunteers: 11 women 33-62 y and 7 men 29-62 y (Mean±SD: 51±12 y) without clinical diagnose but with dysfunction of neuro-endocrine-immune complex and metabolism. In the morning registered HRV (“CardioLab+HRV”, “KhAI-Medica”, Kharkiv, UA), EEG (“NeuroCom Standard”, “KhAI-Medica”, Kharkiv, UA), kirlianogram by the method of GDV (“GDV Chamber”, “Biotechprogress”, SPb, RF), electroconductivity of skin in three pairs of points of acupuncture (“Medissa”), electrokinetic index of buccal epithelium (\"Biotest\", Kharkiv State University), as well as some parameters of immunity and metabolism. After the initial testing, an electrical stimulation session was performed with a “VEB-1”® or a “VEB-2” devices. The next morning after completing the four-day course, retesting was performed. Results. The effects of electrical stimulation can be divided into the following networks. Regarding EEG, this is a leveling of right-hand lateralization and normalizing decrease in the increased of the amplitude of the θ-rhythm and its spectral power density (SPD) at the loci F3, F7, F8, T3, T4, T6, P3, O1 and O2; further increase of SPD of δ-rhythm in loci F3, F4, T6, P3 and O1 as well as further decrease of SPD F4-α; reversion of the increased level of entropy in loci Fp1, F4, C3 and P3 to the lowered level. Regarding HRV, it is a vagotonic shift of sympatho-vagus balance due to a decrease in elevated levels of sympathetic tone markers and an increase in decreased levels of vagus tone markers, but without normalization. Neurotropic effects are accompanied by favorable changes in a number of immune parameters and a tendency to decrease the level of C-Reactive Protein. Regarding GDV, it is almost complete normalization of the initially increased GDI Area in the frontal projection and third Chakra Energy; normalizing decrease in the initially increased Energy of second and seventh Chakras; normalizing right-hand shift of more or less pronounced left-sided Asymmetry of first and third Chakra. These effects should be clearly interpreted as physiologically beneficial. The effects on these parameters are almost equally pronounced in people of both sexes when using both devices. Conclusion. Vagotonic and immunotropic effects of our device give us a reason to offer it for further research on the leveling of “cytokine storm” in patients with COVID-19.","PeriodicalId":43815,"journal":{"name":"Balneo Research Journal","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2020-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Balneo Research Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31219/osf.io/cd4mv","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Background. One of the symptoms of COVID-19 is the so-called "cytokine storm". Its pathogenesis is that the initial release by lymphocytes and macrophages of proinflammatory cytokines in the classical immune response to SARS-CoV-2 is significantly enhanced and maintained due to excessive adrenergic stimulation of the immune cells. The proinflammatory adrenergic mechanism of the "cytokine storm" can be offset by the activation of the anti-inflammatory cholinergic mechanism by non-invasive stimulation of the vagus nerve. In 2015, a generator for electrotherapy and stimulation oh human nerve centers was created, called “VEB-1”®. Preliminary observation of volunteers revealed a modulating effect of a four-day course of electrical stimulation on the parameters of electroencephalogram, metabolism, as well as gas-discharge visualization (GDV). We hypothesized that changes in EEG parameters may be accompanied by a vagotonic shift of the sympatho-vagus balance, favorable for calming the “cytokine storm”. The main purpose of this study was to find out. In addition, concomitant changes in EEG, immunity, GDV, etc. due to the use of the devices "VEB-1"® and recently designed "VEB-2" had to be detected. Material and research methods. The object of observation were 18 volunteers: 11 women 33-62 y and 7 men 29-62 y (Mean±SD: 51±12 y) without clinical diagnose but with dysfunction of neuro-endocrine-immune complex and metabolism. In the morning registered HRV (“CardioLab+HRV”, “KhAI-Medica”, Kharkiv, UA), EEG (“NeuroCom Standard”, “KhAI-Medica”, Kharkiv, UA), kirlianogram by the method of GDV (“GDV Chamber”, “Biotechprogress”, SPb, RF), electroconductivity of skin in three pairs of points of acupuncture (“Medissa”), electrokinetic index of buccal epithelium ("Biotest", Kharkiv State University), as well as some parameters of immunity and metabolism. After the initial testing, an electrical stimulation session was performed with a “VEB-1”® or a “VEB-2” devices. The next morning after completing the four-day course, retesting was performed. Results. The effects of electrical stimulation can be divided into the following networks. Regarding EEG, this is a leveling of right-hand lateralization and normalizing decrease in the increased of the amplitude of the θ-rhythm and its spectral power density (SPD) at the loci F3, F7, F8, T3, T4, T6, P3, O1 and O2; further increase of SPD of δ-rhythm in loci F3, F4, T6, P3 and O1 as well as further decrease of SPD F4-α; reversion of the increased level of entropy in loci Fp1, F4, C3 and P3 to the lowered level. Regarding HRV, it is a vagotonic shift of sympatho-vagus balance due to a decrease in elevated levels of sympathetic tone markers and an increase in decreased levels of vagus tone markers, but without normalization. Neurotropic effects are accompanied by favorable changes in a number of immune parameters and a tendency to decrease the level of C-Reactive Protein. Regarding GDV, it is almost complete normalization of the initially increased GDI Area in the frontal projection and third Chakra Energy; normalizing decrease in the initially increased Energy of second and seventh Chakras; normalizing right-hand shift of more or less pronounced left-sided Asymmetry of first and third Chakra. These effects should be clearly interpreted as physiologically beneficial. The effects on these parameters are almost equally pronounced in people of both sexes when using both devices. Conclusion. Vagotonic and immunotropic effects of our device give us a reason to offer it for further research on the leveling of “cytokine storm” in patients with COVID-19.
“VEB”®装置电刺激在COVID-19相关疾病管理中的应用前景
背景。COVID-19的症状之一是所谓的“细胞因子风暴”。其发病机制是典型的SARS-CoV-2免疫应答中淋巴细胞和巨噬细胞对促炎细胞因子的初始释放因免疫细胞肾上腺素能刺激过度而显著增强和维持。“细胞因子风暴”的促炎肾上腺素能机制可以通过非侵入性刺激迷走神经激活抗炎胆碱能机制来抵消。2015年,一种用于电疗和刺激人类神经中枢的发电机被创造出来,名为“VEB-1”®。对志愿者的初步观察显示,为期四天的电刺激对脑电图、代谢和气体放电可视化(GDV)参数有调节作用。我们假设脑电图参数的变化可能伴随着交感-迷走神经平衡的迷走张力转移,有利于平息“细胞因子风暴”。这项研究的主要目的是找出。此外,由于使用“VEB-1”®和最近设计的“VEB-2”设备,必须检测脑电图、免疫、GDV等的伴随变化。材料和研究方法。观察对象为18名志愿者,其中女性11名,年龄33-62岁,男性7名,年龄29-62岁(Mean±SD: 51±12),无临床诊断,但有神经内分泌免疫复合物及代谢功能障碍。上午注册HRV (CardioLab+HRV),“KhAI-Medica”,Kharkiv, UA),脑电图(“NeuroCom Standard”,“KhAI-Medica”,Kharkiv, UA), GDV法(“GDV Chamber”,“Biotechprogress”,SPb, RF),三对穴位皮肤电导率(“Medissa”),颊上皮电动力学指数(“Biotest”,哈尔科夫国立大学),以及免疫和代谢的一些参数。初始测试后,使用“VEB-1”®或“VEB-2”设备进行电刺激。在完成为期四天的课程后的第二天早上,进行了重新测试。结果。电刺激的作用可分为以下几个网络。脑电图方面,在F3、F7、F8、T3、T4、T6、P3、O1、O2位点,θ-节律幅值及其谱功率密度(SPD)的增加呈右侧偏侧水平化和归一化下降;F3、F4、T6、P3、O1位点δ-节律SPD进一步升高,F4-α SPD进一步降低;基因座Fp1、F4、C3和P3的熵值增加水平恢复到降低水平。关于HRV,它是交感神经-迷走神经平衡的迷走神经性转移,其原因是交感神经张力标记物水平升高而迷走神经张力标记物水平降低,但没有正常化。嗜神经效应伴随着一些免疫参数的有利变化和c反应蛋白水平降低的趋势。关于GDV,它几乎完全归一化最初增加的GDI面积在正面投射和第三脉轮能量;使最初增加的第二和第七脉轮能量的减少正常化;正常化左移或多或少明显的第一和第三脉轮不对称。这些影响应该被清楚地解释为生理上有益的。在使用两种设备时,对这些参数的影响在男女人群中几乎同样明显。结论。该装置的迷走神经张力和免疫增强作用为进一步研究COVID-19患者“细胞因子风暴”的水平提供了理由。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Balneo Research Journal
Balneo Research Journal REHABILITATION-
自引率
0.00%
发文量
0
审稿时长
3 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信