Study on the correlation between HER-2 expression status and multimode ultrasonic characteristics in ER-negative breast cancer

Q4 Medicine
Tianci Wei, Lei Zhang, Jinjin Liu, Jia Kang
{"title":"Study on the correlation between HER-2 expression status and multimode ultrasonic characteristics in ER-negative breast cancer","authors":"Tianci Wei, Lei Zhang, Jinjin Liu, Jia Kang","doi":"10.3760/CMA.J.ISSN.1004-4477.2019.11.010","DOIUrl":null,"url":null,"abstract":"Objective \nTo explore the correlation between the expression status of human epidermal growth factor receptor 2 (HER-2) and the characteristics of conventional ultrasound, shear wave elastography(SWE) and contrast enhanced ultrasound(CEUS) images in breast cancer patients with negative expression of estrogen receptor (ER). \n \n \nMethods \nIn this study, 117 patients with 117 lesions were selected from the Second Hospital of Harbin Medical University Hospital, who had definite pathology and ER negative expression, including 62 patients with positive HER-2 (group Ⅰ) and 55 patients with negative HER-2(group Ⅱ). Conventional ultrasound images and SWE were collected preoperatively, and CEUS images were collected in 62 patients to analyze the correlation between the expression of HER-2 and the ultrasonic characteristics of the three ultrasonic modes. \n \n \nResults \n①Conventional ultrasound: the groupⅠwas characterized by irregular shape, unclear boundary, mainly with spicule edges, microcalcification, axillary lymph node metastasis and higher histological grading. The groupⅡhad no such characteristics (all P<0.05). ②SWE: the Emax, Emean and Eratio of group Ⅰ were higher than group Ⅱ(all P<0.05). ③CEUS: the peak time of group Ⅰ was earlier than group Ⅱ, the slope of ascending branch and the area under the curve were larger, and the characteristics of perforating vessels were easier to be observed, while perfusion defects were more likely to occur in groupⅡ(all P<0.05). \n \n \nConclusions \nIn the case of ER negative expression, there are obvious differences in multimodal sonograms of different breast cancer HER-2 expression conditions. The analysis of the above sonograms will play an important guiding role in the selection of clinical treatment plans. \n \n \nKey words: \nUltrasonography; Breast neoplasms; Shear wave elastography; Contrast-enhanced ultrasound; Human epidermal growth factor receptor 2","PeriodicalId":10224,"journal":{"name":"中华超声影像学杂志","volume":"28 1","pages":"976-980"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华超声影像学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1004-4477.2019.11.010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective To explore the correlation between the expression status of human epidermal growth factor receptor 2 (HER-2) and the characteristics of conventional ultrasound, shear wave elastography(SWE) and contrast enhanced ultrasound(CEUS) images in breast cancer patients with negative expression of estrogen receptor (ER). Methods In this study, 117 patients with 117 lesions were selected from the Second Hospital of Harbin Medical University Hospital, who had definite pathology and ER negative expression, including 62 patients with positive HER-2 (group Ⅰ) and 55 patients with negative HER-2(group Ⅱ). Conventional ultrasound images and SWE were collected preoperatively, and CEUS images were collected in 62 patients to analyze the correlation between the expression of HER-2 and the ultrasonic characteristics of the three ultrasonic modes. Results ①Conventional ultrasound: the groupⅠwas characterized by irregular shape, unclear boundary, mainly with spicule edges, microcalcification, axillary lymph node metastasis and higher histological grading. The groupⅡhad no such characteristics (all P<0.05). ②SWE: the Emax, Emean and Eratio of group Ⅰ were higher than group Ⅱ(all P<0.05). ③CEUS: the peak time of group Ⅰ was earlier than group Ⅱ, the slope of ascending branch and the area under the curve were larger, and the characteristics of perforating vessels were easier to be observed, while perfusion defects were more likely to occur in groupⅡ(all P<0.05). Conclusions In the case of ER negative expression, there are obvious differences in multimodal sonograms of different breast cancer HER-2 expression conditions. The analysis of the above sonograms will play an important guiding role in the selection of clinical treatment plans. Key words: Ultrasonography; Breast neoplasms; Shear wave elastography; Contrast-enhanced ultrasound; Human epidermal growth factor receptor 2
er阴性乳腺癌HER-2表达状况与多模超声特征的相关性研究
目的探讨人表皮生长因子受体2 (HER-2)表达状况与雌激素受体(ER)阴性乳腺癌患者常规超声、剪切波弹性成像(SWE)及超声造影(CEUS)影像特征的相关性。方法选取哈尔滨医科大学附属第二医院病理明确、ER阴性表达的117例患者117个病灶,其中HER-2阳性62例(Ⅰ组),HER-2阴性55例(Ⅱ组),术前收集常规超声图像及SWE。收集62例患者超声造影图像,分析HER-2表达与三种超声模式超声特征的相关性。结果①常规超声:Ⅰ组形态不规则,边界不清,以针状边缘为主,微钙化,腋窝淋巴结转移,组织学分级较高。Ⅱ组无上述特征(均P<0.05)。②SWE:Ⅰ组Emax、Emean、Eratio均高于Ⅱ组(均P<0.05)。③超声造影:Ⅰ组峰值时间比Ⅱ组早,上升支斜率和曲线下面积更大,更容易观察到穿通血管的特征,Ⅱ组更容易出现灌注缺损(均P<0.05)。结论在ER阴性表达的情况下,不同乳腺癌HER-2表达情况的多模态超声图有明显差异。以上超声图的分析将对临床治疗方案的选择起到重要的指导作用。关键词:超声检查;乳腺肿瘤;横波弹性学;对比度增强超声;人表皮生长因子受体2
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
中华超声影像学杂志
中华超声影像学杂志 Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
0.80
自引率
0.00%
发文量
9126
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信