{"title":"Transcatheter pulmonary valvuloplasty with coronary balloon for critical pulmonary atresia with intact ventricular septum in a neonate","authors":"V. Desabandhu, S. Narayanan, Mohanan S Sajeer","doi":"10.4103/heartindia.heartindia_1_20","DOIUrl":null,"url":null,"abstract":"Pulmonary atresia with intact ventricular septum is a rare cause of cyanosis in a newborn. The prognosis and treatment of the condition depend on the pulmonary anatomy as well as the state of the right ventricle. We present a case where the patient presented with acute desaturation, and we had to do an emergency pulmonary valvotomy, using coronary wires and balloons, as a lifesaving procedure. The saturation improved on the table, and the patient could be discharged from hospital in a stable state. This particular case shows that opening an atretic pulmonary valve is a viable option and coronary wires and balloons can be used for the purpose.","PeriodicalId":32147,"journal":{"name":"Heart India","volume":"8 1","pages":"148 - 150"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart India","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/heartindia.heartindia_1_20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Pulmonary atresia with intact ventricular septum is a rare cause of cyanosis in a newborn. The prognosis and treatment of the condition depend on the pulmonary anatomy as well as the state of the right ventricle. We present a case where the patient presented with acute desaturation, and we had to do an emergency pulmonary valvotomy, using coronary wires and balloons, as a lifesaving procedure. The saturation improved on the table, and the patient could be discharged from hospital in a stable state. This particular case shows that opening an atretic pulmonary valve is a viable option and coronary wires and balloons can be used for the purpose.
经导管冠状动脉球囊肺动脉瓣成形术治疗新生儿完全性室间隔肺闭锁1例
肺闭锁与完整的室间隔是一个罕见的原因,在新生儿紫绀。病情的预后和治疗取决于肺解剖和右心室的状态。我们提出一个病例,病人表现出急性去饱和,我们不得不做一个紧急肺动脉瓣切开术,使用冠状动脉电线和气球,作为一个挽救生命的过程。手术台上饱和度提高,患者可以稳定出院。这个特殊的病例表明,打开肺动脉瓣是一个可行的选择,冠状动脉钢丝和球囊可用于此目的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
0
审稿时长
27 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信