{"title":"Correction for the deviation of power system frequency in the measurement of power by digital techniques","authors":"E. Volodarskyi, A. Voloshko","doi":"10.33955/2307-2180(3)2019.27-32","DOIUrl":null,"url":null,"abstract":"The saturation of power supply systems with nonlinear and powerful sources both from sources and consumers of electricity has led to the fact that signals in the network become non-stationary, nonlinear, and with significant frequency fluctuations. The purpose of the work is to reduce the methodological error of determining the parameters of the mode of electricity consumption due to the frequency deviation in the electrical network. The article proposes methods based on the determination of the frequency deviation value and the introduction of correction coefficients (for example, the calculation of active power and voltage in the electric network). The proposed methods are applied to both sinusoidal and non-sinusoidal signal forms. The results show that these methods have high accuracy, even with signals containing harmonics, and for a frequency deviating from the nominal value.","PeriodicalId":52864,"journal":{"name":"Metrologiia ta priladi","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrologiia ta priladi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33955/2307-2180(3)2019.27-32","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The saturation of power supply systems with nonlinear and powerful sources both from sources and consumers of electricity has led to the fact that signals in the network become non-stationary, nonlinear, and with significant frequency fluctuations. The purpose of the work is to reduce the methodological error of determining the parameters of the mode of electricity consumption due to the frequency deviation in the electrical network. The article proposes methods based on the determination of the frequency deviation value and the introduction of correction coefficients (for example, the calculation of active power and voltage in the electric network). The proposed methods are applied to both sinusoidal and non-sinusoidal signal forms. The results show that these methods have high accuracy, even with signals containing harmonics, and for a frequency deviating from the nominal value.
用数字技术校正功率测量中电力系统频率的偏差
具有来自电力来源和用户的非线性和强大电源的供电系统的饱和导致网络中的信号变得非平稳、非线性,并且具有显著的频率波动。这项工作的目的是减少由于电网中的频率偏差而导致的确定用电模式参数的方法误差。文章提出了基于确定频率偏差值和引入校正系数的方法(例如,计算电网中的有功功率和电压)。所提出的方法适用于正弦和非正弦信号形式。结果表明,即使信号含有谐波,并且频率偏离标称值,这些方法也具有高精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
5 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信