{"title":"Implementasi Sistem Monitoring Kualitas Air Berbasis Intellegent Sensor Ph Dan Temperatur Pada Wtp Pnj","authors":"Reza Istoni","doi":"10.30998/faktorexacta.v11i2.2342","DOIUrl":null,"url":null,"abstract":"Water quality is an important parameter of a WTP. Water quality is one measure that the bottled water products are worth consuming and meeting the prevailing standards. Thus research on water quality monitoring is absolutely necessary at this time. Especially in the current pollution level conditions where it is high. WTP PNJ is a ready to drink drinking water treatment industry that has functioned as a leading center in training, teaching and research place. The equipment used to detect and monitor water quality uses a device called Intellegent self-made sensor and is used to detect pH levels and temperature levels in water. As for the monitoring software used LabVIEW. Intelligent sensors in real time have been successful and proven capable of detecting and monitoring water quality at WTP sources in PNJ based on pH and temperature, then sending data and monitored in real time by LabVIEW software. Detected pH is at an average of 4 for a WTP water source, and its temperature is at an average of 28 0 C. while for drinkable water it is measured on average pH of 7 and its temperature is 24 0 C. Based on the results of this monitoring can be used as a reference in the management of WTP PNJ.","PeriodicalId":53004,"journal":{"name":"Faktor Exacta","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Faktor Exacta","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30998/faktorexacta.v11i2.2342","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Water quality is an important parameter of a WTP. Water quality is one measure that the bottled water products are worth consuming and meeting the prevailing standards. Thus research on water quality monitoring is absolutely necessary at this time. Especially in the current pollution level conditions where it is high. WTP PNJ is a ready to drink drinking water treatment industry that has functioned as a leading center in training, teaching and research place. The equipment used to detect and monitor water quality uses a device called Intellegent self-made sensor and is used to detect pH levels and temperature levels in water. As for the monitoring software used LabVIEW. Intelligent sensors in real time have been successful and proven capable of detecting and monitoring water quality at WTP sources in PNJ based on pH and temperature, then sending data and monitored in real time by LabVIEW software. Detected pH is at an average of 4 for a WTP water source, and its temperature is at an average of 28 0 C. while for drinkable water it is measured on average pH of 7 and its temperature is 24 0 C. Based on the results of this monitoring can be used as a reference in the management of WTP PNJ.