The current state of energy efficiency and light quality of led products

IF 0.1 Q4 INSTRUMENTS & INSTRUMENTATION
P. Neyezhmakov, Oleksandr Pitiakov, S. Shpak, Svitlana Kyslytsia, G. Kozhushko
{"title":"The current state of energy efficiency and light quality of led products","authors":"P. Neyezhmakov, Oleksandr Pitiakov, S. Shpak, Svitlana Kyslytsia, G. Kozhushko","doi":"10.24027/2306-7039.1.2022.258690","DOIUrl":null,"url":null,"abstract":"The article presents the results of the energy efficiency study and light quality of LED illuminators (lamps) for general lighting, in particular colorimetric parameters, light flux modulation and photobiological safety. It is shown that two-base LED lamps with G13 base and luminaires for outdoor lighting have achieved energy efficiency class A++. LED lamps with E27 base and indoor lighting fixtures with light diffusers have a light output 25–35% lower and correspond to energy efficiency classes A+, A, B. Correlated color temperature (FTA) of indoor lighting fixtures is mainly in the range of 3000–4500 K, and the total color rendering index Ra – in the range of 71–86 units. The deviation of chromaticity from nominal values can reach 7+ degrees of McAdam ellipses (7+ standard deviations of SDCM comparison color). The angular non-uniformity of color in luminaires with diffuse light diffusers does not exceed 3 SDCM, and for luminaires without light diffusers and with lens optics - can exceed 7+ SDCM. \nIt is shown that LED luminaires for indoor lighting have a mainly safe level of flicker and visibility of the stroboscopic effect. In the frequency range up to 80 Hz, the flicker level, which is observed with a probability of 50% lower than incandescent lamps with a power of 60 watts. In the frequency range up to 3000 Hz, the modulation depth corresponds to a level that does not create adverse biological effects. \nLED lamps and illuminators for general lighting entering the lighting market do not exceed the parameters of the insignificant risk danger group of blue light RG1. Lamps and illuminators using diffuse light diffusers belong to the general group RG0 (no risk). \nConclusions are made on energy efficiency and light quality of LED lamps.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2022-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ukrainian Metrological Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24027/2306-7039.1.2022.258690","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

The article presents the results of the energy efficiency study and light quality of LED illuminators (lamps) for general lighting, in particular colorimetric parameters, light flux modulation and photobiological safety. It is shown that two-base LED lamps with G13 base and luminaires for outdoor lighting have achieved energy efficiency class A++. LED lamps with E27 base and indoor lighting fixtures with light diffusers have a light output 25–35% lower and correspond to energy efficiency classes A+, A, B. Correlated color temperature (FTA) of indoor lighting fixtures is mainly in the range of 3000–4500 K, and the total color rendering index Ra – in the range of 71–86 units. The deviation of chromaticity from nominal values can reach 7+ degrees of McAdam ellipses (7+ standard deviations of SDCM comparison color). The angular non-uniformity of color in luminaires with diffuse light diffusers does not exceed 3 SDCM, and for luminaires without light diffusers and with lens optics - can exceed 7+ SDCM. It is shown that LED luminaires for indoor lighting have a mainly safe level of flicker and visibility of the stroboscopic effect. In the frequency range up to 80 Hz, the flicker level, which is observed with a probability of 50% lower than incandescent lamps with a power of 60 watts. In the frequency range up to 3000 Hz, the modulation depth corresponds to a level that does not create adverse biological effects. LED lamps and illuminators for general lighting entering the lighting market do not exceed the parameters of the insignificant risk danger group of blue light RG1. Lamps and illuminators using diffuse light diffusers belong to the general group RG0 (no risk). Conclusions are made on energy efficiency and light quality of LED lamps.
led产品的能效和光质量现状
本文介绍了普通照明用LED照明器(灯)的能效研究结果和光质量,特别是色度参数、光通量调制和光生物安全。结果表明,G13底座的两个底座LED灯和户外照明灯具已达到A++级能效。带有E27底座的LED灯和带有光漫射器的室内照明灯具的光输出降低了25-35%,对应于a+、a、B级能效。室内照明设备的相关色温(FTA)主要在3000-4500K范围内,总显色指数Ra在71~86个单位范围内。色度与标称值的偏差可以达到McAdam椭圆的7+度(SDCM比较色的7+标准偏差)。具有漫射光漫射器的灯具的颜色角度不均匀性不超过3 SDCM,而对于没有漫射器和透镜光学器件的灯具,颜色角度不一致性可以超过7+SDCM。研究表明,室内照明用LED灯具具有主要安全的闪烁水平和频闪效应的可视性。在高达80Hz的频率范围内,观察到的闪烁水平比功率为60瓦的白炽灯低50%的概率。在高达3000Hz的频率范围内,调制深度对应于不会产生不利生物影响的水平。进入照明市场的普通照明用LED灯和照明器不超过蓝光RG1的不显著风险危险组的参数。使用漫射光漫射器的灯具和照明器属于一般类别RG0(无风险)。对LED灯的能效和光照质量进行了总结。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ukrainian Metrological Journal
Ukrainian Metrological Journal INSTRUMENTS & INSTRUMENTATION-
自引率
0.00%
发文量
21
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信