Assessment of Central Vault Changes induced By Cyclopentolate In Myopic Patients Implanted with the Implantable Phakic Contact Lens®

IF 0.1 Q4 OPHTHALMOLOGY
Amr E. Elbakry, M. Attia, Hoda El Shiwy, A. Hassanein, M. Sidky
{"title":"Assessment of Central Vault Changes induced By Cyclopentolate In Myopic Patients Implanted with the Implantable Phakic Contact Lens®","authors":"Amr E. Elbakry, M. Attia, Hoda El Shiwy, A. Hassanein, M. Sidky","doi":"10.4103/ejos.ejos_107_22","DOIUrl":null,"url":null,"abstract":"Background A safe alternative to excimer laser in fixing high myopia is the implantable phakic contact lens (IPCL). Cycloplegics have been found to produce vault changes in the implantable collamer lens but not tested yet for the IPCL. Purpose To analyze central vault changes linked with instillation of cyclopentolate in myopic IPCL implanted patients and its association with anterior chamber depth (ACD), pupillary diameter, and white-to-white (WTW) diameter. Patients and methods This prospective study assessed the left eyes of 37 patients. Patients were followed up for 3 months postoperatively. The basic outcome measures were the safety and efficacy indices, while the main outcome was the vault measurements before and after cyclopentolate. Results Twenty (54.1%) females and 17 (45.9%) males, with a mean age of 24±4 years (18–32) were recruited. The safety index was 1.08±0.07 and the efficacy index was 0.99±0.1. There was a significant increase in central vault ‘V(C)’ after cyclopentolate [83.7±86.7 μm (−48 to 303); P<0.001). A good positive correlation existed between V(C) and ACD (r=0.7, P<0.001), and a fair correlation with pupil diameter (r=0.4, P=0.014), WTW (r=0.39, P=0.017), and the original vault ‘V(B)’ (r=0.34, P=004) was demonstrated. Conclusion Cyclopentolate induces an increase in central vault in most IPCL implanted myopic eyes, which is typically associated with ACD, pupillary diameter, WTW, and the original vault. Care should be advised to avoid angle narrowing.","PeriodicalId":31572,"journal":{"name":"Journal of the Egyptian Ophthalmological Society","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Egyptian Ophthalmological Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ejos.ejos_107_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background A safe alternative to excimer laser in fixing high myopia is the implantable phakic contact lens (IPCL). Cycloplegics have been found to produce vault changes in the implantable collamer lens but not tested yet for the IPCL. Purpose To analyze central vault changes linked with instillation of cyclopentolate in myopic IPCL implanted patients and its association with anterior chamber depth (ACD), pupillary diameter, and white-to-white (WTW) diameter. Patients and methods This prospective study assessed the left eyes of 37 patients. Patients were followed up for 3 months postoperatively. The basic outcome measures were the safety and efficacy indices, while the main outcome was the vault measurements before and after cyclopentolate. Results Twenty (54.1%) females and 17 (45.9%) males, with a mean age of 24±4 years (18–32) were recruited. The safety index was 1.08±0.07 and the efficacy index was 0.99±0.1. There was a significant increase in central vault ‘V(C)’ after cyclopentolate [83.7±86.7 μm (−48 to 303); P<0.001). A good positive correlation existed between V(C) and ACD (r=0.7, P<0.001), and a fair correlation with pupil diameter (r=0.4, P=0.014), WTW (r=0.39, P=0.017), and the original vault ‘V(B)’ (r=0.34, P=004) was demonstrated. Conclusion Cyclopentolate induces an increase in central vault in most IPCL implanted myopic eyes, which is typically associated with ACD, pupillary diameter, WTW, and the original vault. Care should be advised to avoid angle narrowing.
环戊酸盐对植入植入性隐形眼镜的近视患者中央拱顶变化的评价
背景植入式隐形眼镜是准分子激光治疗高度近视的一种安全的替代方法。已发现睫状体麻痹患者可在植入式结晶体中产生穹窿变化,但尚未对IPCL进行测试。目的分析环戊酸酯在近视IPCL植入术中灌注引起的中央穹窿变化及其与前房深度(ACD)、瞳孔直径和白到白直径(WTW)的关系。本前瞻性研究评估了37例患者的左眼。术后随访3个月。基本指标为安全性和有效性指标,主要指标为环戊酸酯治疗前后的拱顶测量。结果女性20例(54.1%),男性17例(45.9%),年龄18 ~ 32岁,平均24±4岁。安全性指数为1.08±0.07,有效性指数为0.99±0.1。环戊酸盐[83.7±86.7 μm(−48 ~ 303)]后,中央拱顶' V(C) '显著增加;P < 0.001)。V(C)与ACD呈良好的正相关(r=0.7, P<0.001),与瞳孔直径(r=0.4, P=0.014)、WTW (r=0.39, P=0.017)、原始拱顶' V(B) ' (r=0.34, P=004)呈良好的正相关。结论环戊酸盐可引起大多数IPCL植入性近视眼中央穹窿的增加,这种增加与ACD、瞳孔直径、WTW和原始穹窿有关。应注意避免角度变窄。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
8
审稿时长
19 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信