Assessment of Corrosion and Scale forming Potential of Groundwater Resources: Case Study of Dire Dawa City, Ethiopia

IF 0.3 Q4 MULTIDISCIPLINARY SCIENCES
Girmaye Haile Gebremikael, Aman Hussien Dawod
{"title":"Assessment of Corrosion and Scale forming Potential of Groundwater Resources: Case Study of Dire Dawa City, Ethiopia","authors":"Girmaye Haile Gebremikael, Aman Hussien Dawod","doi":"10.4314/mejs.v13i1.6","DOIUrl":null,"url":null,"abstract":"Almost 100% of the water supply of Dire Dawa City is from groundwater (including boreholes, dug wells, and springs). Recently, groundwater cause corrosion and scale problems to water distribution systems due to its content of dissolved ions that can cause public health and economic issues. The present paper investigates the corrosion and scale-forming potential of the groundwater in the city and visualizes it with mapping. Spectrophotometer, EDTA/Acid titration with calculation methods were used for water quality parameters analysis. GW Chart Calibration plot applied for the Piper diagram to categorizes the water types. Langelier saturation (LSI), Ryznar (RSI), aggressive (AI), Puckorius Scale (PSI), and Larson-Skold (LRI) indices were manipulated with Excel ® and visualized their spatial distribution using ArcGIS 10®. The mean values of LSI, RSI, PSI, AI, and LRI obtained were 0.29 ± 0.28, 6.4 ± 0.5, 5.10 ± 0.48, 12.20 ± 0.24, and 1.4±1.57 respectively. LSI and RSI results indicate moderate to low scale-forming tendency of groundwater in most parts except the northeastern part with corrosive groundwater. Based on the AI value, the groundwater ranges low corrosion in almost all zones except the edge of the northeast and northwest region. PSI indicated the water tends to form salt-scale at a medium rate. The LSI results showed that chloride and sulphate are unlikely to interfere with the formation of protecting film except in northwestern and northeastern regions where localized corrosion might occur. In conclusion, in almost all distribution system of the city is affected by calcium carbonate scale formation. The groundwater in the northwest and northeast resulted in localized corrosion because of relatively high contents of chlorides and sulphates.","PeriodicalId":18948,"journal":{"name":"Momona Ethiopian Journal of Science","volume":"1 1","pages":""},"PeriodicalIF":0.3000,"publicationDate":"2021-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Momona Ethiopian Journal of Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/mejs.v13i1.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 4

Abstract

Almost 100% of the water supply of Dire Dawa City is from groundwater (including boreholes, dug wells, and springs). Recently, groundwater cause corrosion and scale problems to water distribution systems due to its content of dissolved ions that can cause public health and economic issues. The present paper investigates the corrosion and scale-forming potential of the groundwater in the city and visualizes it with mapping. Spectrophotometer, EDTA/Acid titration with calculation methods were used for water quality parameters analysis. GW Chart Calibration plot applied for the Piper diagram to categorizes the water types. Langelier saturation (LSI), Ryznar (RSI), aggressive (AI), Puckorius Scale (PSI), and Larson-Skold (LRI) indices were manipulated with Excel ® and visualized their spatial distribution using ArcGIS 10®. The mean values of LSI, RSI, PSI, AI, and LRI obtained were 0.29 ± 0.28, 6.4 ± 0.5, 5.10 ± 0.48, 12.20 ± 0.24, and 1.4±1.57 respectively. LSI and RSI results indicate moderate to low scale-forming tendency of groundwater in most parts except the northeastern part with corrosive groundwater. Based on the AI value, the groundwater ranges low corrosion in almost all zones except the edge of the northeast and northwest region. PSI indicated the water tends to form salt-scale at a medium rate. The LSI results showed that chloride and sulphate are unlikely to interfere with the formation of protecting film except in northwestern and northeastern regions where localized corrosion might occur. In conclusion, in almost all distribution system of the city is affected by calcium carbonate scale formation. The groundwater in the northwest and northeast resulted in localized corrosion because of relatively high contents of chlorides and sulphates.
地下水资源腐蚀和结垢潜力评价——以埃塞俄比亚迪勒达瓦市为例
迪勒达瓦市几乎100%的供水来自地下水(包括钻孔、挖井和泉水)。最近,地下水由于其溶解离子的含量而引起供水系统的腐蚀和结垢问题,这可能导致公共卫生和经济问题。本文研究了城市地下水的腐蚀和结垢潜力,并用制图将其可视化。采用分光光度法、EDTA/酸滴定法计算水质参数。GW图用于Piper图的校准图,用于对水类型进行分类。Langelier saturation (LSI)、Ryznar (RSI)、aggressive (AI)、Puckorius Scale (PSI)和Larson-Skold (LRI)指数使用Excel®进行处理,并使用ArcGIS 10®对其空间分布进行可视化。LSI、RSI、PSI、AI、LRI的平均值分别为0.29±0.28、6.4±0.5、5.10±0.48、12.20±0.24、1.4±1.57。LSI和RSI结果表明,除东北地区有腐蚀性地下水外,大部分地区地下水有中低结垢倾向。从AI值来看,除东北和西北边缘地区外,几乎所有地区的地下水都处于低腐蚀状态。PSI表明水倾向于以中等速率形成盐垢。LSI的结果表明,除了可能发生局部腐蚀的西北和东北地区外,氯化物和硫酸盐不太可能干扰保护膜的形成。综上所述,在几乎所有的城市分布系统中都受到碳酸钙结垢的影响。西北和东北地区地下水氯化物和硫酸盐含量较高,造成局部腐蚀。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Momona Ethiopian Journal of Science
Momona Ethiopian Journal of Science MULTIDISCIPLINARY SCIENCES-
自引率
0.00%
发文量
13
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信