Intra-Oral Ultrasonography of Young Adult Mandibular Foramen: A Reliable Method

IF 0.2 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
M. Mehdizadeh, Negar Baharlouei, H. Taheri
{"title":"Intra-Oral Ultrasonography of Young Adult Mandibular Foramen: A Reliable Method","authors":"M. Mehdizadeh, Negar Baharlouei, H. Taheri","doi":"10.5812/iranjradiol.111237","DOIUrl":null,"url":null,"abstract":"Background: The inferior alveolar nerve (IAN) block is the most commonly used mandibular injection method for local anesthesia in restorative and surgical procedures. Ultrasound images can provide more accurate information about the location of the inferior alveolar neurovascular bundle. Objectives: This study aimed to evaluate the ultrasound images of patients to determine the location of the mandibular foramen (MF) relative to the adjacent landmarks. Patients and Methods: In this cross-sectional analytical study, 50 patients were subjected to intra-oral ultrasonography of the right and left sides of the mandible. An Alpinion ultrasound system (Seoul, South Korea) was used for detecting the MF, as well as its distance from different landmarks. Results: In all patients, the MF was found using color Doppler ultrasonography. The probability of detecting MF in conventional ultrasonography was estimated at 36% and 18% for the right and left sides of the mandible without using the Doppler technique, respectively. The mean MF distance from the anterior border of the ramus was 14.6 ± 2.1 and 16.1 ± 2.1 mm on the right and left sides, respectively. Also, the vertical distance of MF from the occlusal plane was 7.5 ± 1.1 mm on the right side and 8.7 ± 1.2 mm on the left side of the mandible. In all studied patients, the MF was above the occlusal plane. Conclusion: The results of this study showed that ultrasonography is not only a suitable option for intra-oral imaging due to its non-ionizing beams, but is also appropriate for localization of the MF and its related landmarks.","PeriodicalId":50273,"journal":{"name":"Iranian Journal of Radiology","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2021-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5812/iranjradiol.111237","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 2

Abstract

Background: The inferior alveolar nerve (IAN) block is the most commonly used mandibular injection method for local anesthesia in restorative and surgical procedures. Ultrasound images can provide more accurate information about the location of the inferior alveolar neurovascular bundle. Objectives: This study aimed to evaluate the ultrasound images of patients to determine the location of the mandibular foramen (MF) relative to the adjacent landmarks. Patients and Methods: In this cross-sectional analytical study, 50 patients were subjected to intra-oral ultrasonography of the right and left sides of the mandible. An Alpinion ultrasound system (Seoul, South Korea) was used for detecting the MF, as well as its distance from different landmarks. Results: In all patients, the MF was found using color Doppler ultrasonography. The probability of detecting MF in conventional ultrasonography was estimated at 36% and 18% for the right and left sides of the mandible without using the Doppler technique, respectively. The mean MF distance from the anterior border of the ramus was 14.6 ± 2.1 and 16.1 ± 2.1 mm on the right and left sides, respectively. Also, the vertical distance of MF from the occlusal plane was 7.5 ± 1.1 mm on the right side and 8.7 ± 1.2 mm on the left side of the mandible. In all studied patients, the MF was above the occlusal plane. Conclusion: The results of this study showed that ultrasonography is not only a suitable option for intra-oral imaging due to its non-ionizing beams, but is also appropriate for localization of the MF and its related landmarks.
年轻成人下颌骨Foramen的口腔内超声检查:一种可靠的方法
背景:下牙槽神经阻滞是修复和外科手术中最常用的下颌局部麻醉注射方法。超声图像可以提供关于下肺泡神经血管束位置的更准确信息。目的:本研究旨在评估患者的超声图像,以确定下颌孔(MF)相对于邻近地标的位置。患者和方法:在本横断面分析研究中,对50例患者进行了下颌骨左右两侧的口腔内超声检查。Alpinion超声系统(首尔,韩国)用于检测中频及其与不同地标的距离。结果:所有患者均采用彩色多普勒超声检查发现MF。不使用多普勒技术,常规超声检测下颌左右两侧MF的概率分别为36%和18%。右、左两侧距支前缘平均MF距离分别为14.6±2.1 mm和16.1±2.1 mm。下颌下颌关节与咬合面垂直距离右侧为7.5±1.1 mm,左侧为8.7±1.2 mm。在所有研究的患者中,MF位于咬合平面上方。结论:本研究结果表明,超声检查不仅因其非电离光束而成为口腔内成像的一种合适选择,而且适合定位MF及其相关标志。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Iranian Journal of Radiology
Iranian Journal of Radiology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
0.50
自引率
0.00%
发文量
33
审稿时长
>12 weeks
期刊介绍: The Iranian Journal of Radiology is the official journal of Tehran University of Medical Sciences and the Iranian Society of Radiology. It is a scientific forum dedicated primarily to the topics relevant to radiology and allied sciences of the developing countries, which have been neglected or have received little attention in the Western medical literature. This journal particularly welcomes manuscripts which deal with radiology and imaging from geographic regions wherein problems regarding economic, social, ethnic and cultural parameters affecting prevalence and course of the illness are taken into consideration. The Iranian Journal of Radiology has been launched in order to interchange information in the field of radiology and other related scientific spheres. In accordance with the objective of developing the scientific ability of the radiological population and other related scientific fields, this journal publishes research articles, evidence-based review articles, and case reports focused on regional tropics. Iranian Journal of Radiology operates in agreement with the below principles in compliance with continuous quality improvement: 1-Increasing the satisfaction of the readers, authors, staff, and co-workers. 2-Improving the scientific content and appearance of the journal. 3-Advancing the scientific validity of the journal both nationally and internationally. Such basics are accomplished only by aggregative effort and reciprocity of the radiological population and related sciences, authorities, and staff of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信