{"title":"Endovascular repair of a complex renal artery aneurysm using PipelineTM Embolization Device (PED) assisted coil embolization.","authors":"Jeff Liang, G. Duckwiler, J. Middleton, J. Moriarty, J. McWilliams","doi":"10.3941/jrcr.v15i10.4156","DOIUrl":null,"url":null,"abstract":"Background\nWe describe the treatment of a renal artery aneurysm with complex anatomy using coils and the PipelineTM Embolization Device (Medtronic, Irvine, CA), a flow-diverting stent typically used for the treatment of intracranial aneurysms.\n\n\nMethods\nA 62-year-old female with history of an asymptomatic right renal artery aneurysm that was discovered incidentally 10 years ago was found to have enlargement of the aneurysm (1.9cm to 2.7cm) on a repeat surveillance CT scan. She was successfully treated with combined Pipeline Embolization Device and coil embolization of the aneurysm sac.\n\n\nResults\nPost-procedural angiography showed complete occlusion of the aneurysm with maintenance of perfusion to the entire kidney.\n\n\nConclusion\nPipelineTM assisted coil embolization may be an option for parenchyma-sparing treatment of renal artery aneurysms with complex anatomy.","PeriodicalId":46520,"journal":{"name":"Journal of Radiology Case Reports","volume":"15 10 1","pages":"1-9"},"PeriodicalIF":0.7000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiology Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3941/jrcr.v15i10.4156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background
We describe the treatment of a renal artery aneurysm with complex anatomy using coils and the PipelineTM Embolization Device (Medtronic, Irvine, CA), a flow-diverting stent typically used for the treatment of intracranial aneurysms.
Methods
A 62-year-old female with history of an asymptomatic right renal artery aneurysm that was discovered incidentally 10 years ago was found to have enlargement of the aneurysm (1.9cm to 2.7cm) on a repeat surveillance CT scan. She was successfully treated with combined Pipeline Embolization Device and coil embolization of the aneurysm sac.
Results
Post-procedural angiography showed complete occlusion of the aneurysm with maintenance of perfusion to the entire kidney.
Conclusion
PipelineTM assisted coil embolization may be an option for parenchyma-sparing treatment of renal artery aneurysms with complex anatomy.