Santunu Purohit, A. Meaze, SM Enamul Kabir, Md. Shakilur Rahman, Md. Kawchar Ahmed Patwary
{"title":"Suitability of chambers in relative dose measurement of small fields for accelerated photon delivered from medical linear accelerator","authors":"Santunu Purohit, A. Meaze, SM Enamul Kabir, Md. Shakilur Rahman, Md. Kawchar Ahmed Patwary","doi":"10.22038/IJMP.2020.46202.1721","DOIUrl":null,"url":null,"abstract":"Aims: Uses of small field in modern radiotherapy our present work is devoted to measure the relative dosimetry (scattering factors, percentage depth doses and profile’s penumbra) with ionization (FC65-G, CC13, CC01) and diode (Razor) chambers.Methods and materials: Applying TRS-398 in Varian Clinac IX-5982 for 6 MV photon beams keeping the conditions (pressure, temperature, direction, polarity) same for a set of field sizes (1 × 1, 2 × 2, 3 × 3, 4 × 4, 5 × 5, 7 × 7 and 10 × 10 cm2) relative dosimetry was performed at the North East Cancer Hospital, Sylhet, Bangladesh. Results: During output factor measurement in small fields Razor shows better result than CC13. Taking CC01 as a standard one in small field our measured data showed good agreement with previous published works.Conclusion: Razor having extremely small active volume is very suited for small field dosimetry except PDDs was experimentally found.","PeriodicalId":14613,"journal":{"name":"Iranian Journal of Medical Physics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/IJMP.2020.46202.1721","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0
Abstract
Aims: Uses of small field in modern radiotherapy our present work is devoted to measure the relative dosimetry (scattering factors, percentage depth doses and profile’s penumbra) with ionization (FC65-G, CC13, CC01) and diode (Razor) chambers.Methods and materials: Applying TRS-398 in Varian Clinac IX-5982 for 6 MV photon beams keeping the conditions (pressure, temperature, direction, polarity) same for a set of field sizes (1 × 1, 2 × 2, 3 × 3, 4 × 4, 5 × 5, 7 × 7 and 10 × 10 cm2) relative dosimetry was performed at the North East Cancer Hospital, Sylhet, Bangladesh. Results: During output factor measurement in small fields Razor shows better result than CC13. Taking CC01 as a standard one in small field our measured data showed good agreement with previous published works.Conclusion: Razor having extremely small active volume is very suited for small field dosimetry except PDDs was experimentally found.
期刊介绍:
Iranian Journal of Medical Physics (IJMP) is the official scientific bimonthly publication of the Iranian Association of Medical Physicists. IJMP is an international and multidisciplinary journal, peer review, free of charge publication and open access. This journal devoted to publish Original Papers, Review Articles, Short Communications, Technical Notes, Editorial and Letters to the Editor in the field of “Medical Physics” involving both basic and clinical research. Submissions of manuscript from all countries are welcome and will be reviewed by at least two expert reviewers.