V. Guryev, S. Vlasenko, S. Shcherbak, D. Lazakovich, A. Khilchuk, M. Agarkov, V. V. Semenyuta, D. A. Vorobyevsky, D. Gladyshev, A. Osadchiy
{"title":"Endovascular occlusion of the left atrialaud in patients with atrial fibrillations. Experience of city hospital","authors":"V. Guryev, S. Vlasenko, S. Shcherbak, D. Lazakovich, A. Khilchuk, M. Agarkov, V. V. Semenyuta, D. A. Vorobyevsky, D. Gladyshev, A. Osadchiy","doi":"10.18705/2311-4495-2021-6-24-32","DOIUrl":null,"url":null,"abstract":"Background. Endovascular occlusion of the left atrial appendage (LAA) using the Watchman device may be considered an adequate alternative to oral anticoagulant (OAC) administration in high-risk patients.Objective. To describe our experience with Watchman endovascular occlusion of the left atrial appendage in a city hospital setting in terms of feasibility and safety, as well as assess the short-term efficacy of this procedure.Design and methods. The study included patients who underwent implantation of the Watchman occlusion device from January 2016 to November 2020. The effectiveness of the procedure was defined as the ability to implant the Watchman without maintaining residual current, safety was defined as the occurrence of nosocomial and 45-day events including stroke, pericardial effusion, major bleeding, and device migration.Results. The study included 22 patients: 10 men and 12 women, who underwent implantation of the Watchman occluding device in the LAA. The indication for implantation was a history of gastrointestinal bleeding in 15 patients, cerebral hemorrhage in 3 patients and low compliance to therapy in 4 patients. The success rate of the procedure was 95.7 %. According to control transesophageal echocardiography, after 45 days LAA was excluded from the bloodstream in 21 of 22 patients.Conclusion. Despite the higher complication rate of occlusion of the LAA compared to drug treatment, the overall mortality from any cause in patients with the implanted Watchman was lower.","PeriodicalId":89863,"journal":{"name":"Translational medicine (Sunnyvale, Calif.)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Translational medicine (Sunnyvale, Calif.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18705/2311-4495-2021-6-24-32","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background. Endovascular occlusion of the left atrial appendage (LAA) using the Watchman device may be considered an adequate alternative to oral anticoagulant (OAC) administration in high-risk patients.Objective. To describe our experience with Watchman endovascular occlusion of the left atrial appendage in a city hospital setting in terms of feasibility and safety, as well as assess the short-term efficacy of this procedure.Design and methods. The study included patients who underwent implantation of the Watchman occlusion device from January 2016 to November 2020. The effectiveness of the procedure was defined as the ability to implant the Watchman without maintaining residual current, safety was defined as the occurrence of nosocomial and 45-day events including stroke, pericardial effusion, major bleeding, and device migration.Results. The study included 22 patients: 10 men and 12 women, who underwent implantation of the Watchman occluding device in the LAA. The indication for implantation was a history of gastrointestinal bleeding in 15 patients, cerebral hemorrhage in 3 patients and low compliance to therapy in 4 patients. The success rate of the procedure was 95.7 %. According to control transesophageal echocardiography, after 45 days LAA was excluded from the bloodstream in 21 of 22 patients.Conclusion. Despite the higher complication rate of occlusion of the LAA compared to drug treatment, the overall mortality from any cause in patients with the implanted Watchman was lower.